1. Introduction
This manual provides essential information for the safe and efficient operation of the Srliya NFLIXIN 9600-3T-01500G Variable Frequency Drive (VFD). Please read this manual thoroughly before installation, operation, or maintenance to ensure proper usage and prevent potential hazards. This VFD is designed to control AC motors by adjusting the frequency of the motor's power supply.
2. Safety Information
WARNING: Risk of Electric Shock. Installation and maintenance must be performed by qualified professionals only.
- Always read the instruction manual completely before any operation.
- Disconnect the power supply and wait at least 5 minutes before performing any maintenance or inspection on this equipment. This allows residual voltage to dissipate.
- Ensure the VFD is installed indoors, away from direct sunlight, dust, corrosive or flammable gases, oily smoke, steam, water, or any other liquids and salt.
- Do not operate the VFD with wet hands.
- Ensure proper grounding to prevent electric shock.
3. Product Overview
The Srliya NFLIXIN 9600-3T-01500G is a robust Variable Frequency Drive designed for industrial applications. It features advanced control capabilities and multiple protection mechanisms to ensure reliable motor operation.
3.1 Key Features
- Smart Design: Utilizes premium IGBT technology for efficient and reliable performance.
- AC Motor VFD: Controls AC motors by precisely changing the frequency of the motor's working power supply.
- Fast Cooling: Equipped with a powerful cooling fan for excellent heat dissipation and stable operation.
- Comprehensive Control: Includes automatic carrier frequency adjustment, V/F control, DC braking, RS485 communication, and more.
- Multiple Protections: Features safeguards against overcurrent, overvoltage, undervoltage, overload, and overheating, including a built-in filter module.
3.2 Product Components and Views




4. Specifications
| Parameter | Value |
|---|---|
| Model | 9600-3T-01500G |
| Material | ABS |
| Input Voltage | Single Phase 380V |
| Input Frequency | 50-60Hz |
| Output Voltage | 3 Phase 0-380V |
| Output Frequency | 0-650Hz |
| Rated Power | 15KW |
| Rated Current | 32A |
| Adaptive Motor | 15KW 20HP |
| Dimensions (Approx.) | 25 x 18 x 16cm / 9.84 x 7.09 x 6.3in |
| Overload Capacity | 150% |
| Carrier Frequency Automatic Adjustment | Yes |
| Sensorless Vector Control | Yes |
| RS485 Communication | Yes |
| Starting Torsion | 0.5Hz/150% |
| Frequency Resolution | 0.1Hz |
| Maximum Frequency | 3200Hz |
| V/F Curve Separation | Yes |
| Adjustable V/F Curve | Yes |
| DC Braking | Yes |
| Quick Current Limit | Yes |
| Motor Short Circuit Detection (Power On) | Yes |
5. Installation
5.1 Environmental Requirements
- Install the VFD indoors.
- Avoid direct sunlight.
- Ensure the environment is free from excessive dust, corrosive or flammable gases.
- Protect from oily smoke, steam, water, or any other liquids and salt.
- Maintain adequate ventilation around the unit for proper heat dissipation.
5.2 Mounting
Mount the VFD securely using appropriate fasteners. Refer to Figure 3.2.4 for the mounting grid on the bottom of the unit. Ensure the mounting surface is stable and can support the weight of the VFD.
5.3 Wiring
All wiring must be performed by a qualified electrician in accordance with local and national electrical codes. Ensure the input power matches the VFD's specifications (Single Phase 380V). Connect the 3-phase motor to the VFD's output terminals. Proper grounding is essential.
6. Operating Instructions
6.1 Control Panel Overview
The VFD features a user-friendly control panel with a digital display and various buttons for operation and parameter setting.

- Digital Display: Shows operating frequency, output current, voltage, and parameter values.
- RUN Button (Green): Initiates motor operation.
- STOP/RESET Button (Red): Stops motor operation and resets fault conditions.
- PRG (Program) Button: Enters/exits parameter setting mode.
- SHIFT Button: Moves cursor or shifts digits during parameter editing.
- ENTER Button: Confirms parameter settings or enters sub-menus.
- Up/Down Arrow Buttons: Adjust parameter values or navigate through menus.
6.2 Basic Operation
- Power On: After ensuring all connections are secure and safe, apply power to the VFD. The display will illuminate.
- Start Motor: Press the RUN button to start the motor. The VFD will accelerate the motor to the set frequency.
- Stop Motor: Press the STOP/RESET button to stop the motor. The VFD will decelerate the motor to a stop.
- Adjust Frequency: Use the Up/Down arrow buttons to adjust the output frequency (and thus motor speed) during operation, if configured for keypad control.
6.3 Parameter Setting
To access and modify VFD parameters, press the PRG button. Navigate through the parameter groups and individual parameters using the Up/Down arrows. Use the SHIFT button to move between digits and the ENTER button to confirm changes. Refer to the detailed parameter list in the included physical user manual for specific parameter functions and ranges.
7. Maintenance
Regular maintenance ensures the longevity and optimal performance of your VFD.
- Cleaning: Periodically clean the VFD's exterior and ventilation grilles to prevent dust accumulation, which can hinder cooling. Ensure power is disconnected before cleaning.
- Inspection: Regularly inspect wiring connections for tightness and signs of wear or damage. Check for any unusual noises or vibrations during operation.
- Cooling Fan: Ensure the cooling fan operates freely and is not obstructed. Replace if it becomes noisy or stops functioning.
- Environmental Check: Verify that the operating environment continues to meet the specified conditions (temperature, humidity, absence of contaminants).
8. Troubleshooting
This section provides guidance for common issues. For complex problems, contact technical support.
| Problem | Possible Cause | Solution |
|---|---|---|
| VFD does not power on | No input power; Blown fuse; Internal fault | Check power supply; Inspect fuses; Contact support |
| Motor does not start | Incorrect wiring; Parameter settings; Emergency stop active | Verify wiring; Check parameters (e.g., start source); Reset E-stop |
| Overcurrent fault | Motor overload; Short circuit in motor/cables; Rapid acceleration | Reduce load; Check motor/cables; Adjust acceleration time |
| Overvoltage fault | High input voltage; Rapid deceleration; Regenerative load | Check input voltage; Increase deceleration time; Install braking resistor if needed |
| Overheat fault | Insufficient ventilation; High ambient temperature; Fan failure | Improve ventilation; Reduce ambient temp; Check/replace fan |
9. Warranty and Support
For warranty information, please refer to the documentation provided at the time of purchase or contact your vendor. For technical support, assistance with advanced configurations, or troubleshooting issues not covered in this manual, please contact Srliya customer service or your authorized distributor.