Important Safety Information
Please read this manual carefully before installation and use. Keep this manual for future reference.
- This detector is designed to detect both methane (CH4) and carbon monoxide (CO) gas.
- Do not ignore any alarm. Investigate the cause immediately.
- The device features UL1484 and UL2034 reports, indicating compliance with safety standards.
- This device can also assist in the detection of ethane, propane, and liquefied gas, but the response time for these gases may be longer (10-40 minutes).
- Ensure proper ventilation and never use open flames to test the detector.
Product Overview
The AOTIQUAL Model 750 is a battery-powered dual-sensor detector designed for comprehensive safety monitoring in homes, RVs, kitchens, and apartments.
Key Features:
- Dual Safety Detection: Detects methane (CH4) and carbon monoxide (CO).
- Advanced Leak Detection: Quickly detects leaks within 10 seconds for CO and CH4.
- Reliable Alerts: Equipped with an LED display and audible/visual alerts.
- Alarm Thresholds: CO at 150 PPM, CH4 at 8% LEL.
- Battery-Powered: Operates on 3 AA batteries (included in some packages).
- High Performance Semiconductor Sensor: Imported from Japan, UL certified (E193211).
- 10-Year Sensor Life: Long-lasting sensor for extended protection.
Included Components:
- AOTIQUAL Natural Gas and Carbon Monoxide Detector (Model 750)
- 1.5V AA Batteries (x3)
- Mounting Screws (x2)
- User Manual

Image: Front view of the AOTIQUAL Model 750 Natural Gas and Carbon Monoxide Detector with its LED display.

Image: Diagram illustrating the internal components and design of the AOTIQUAL Model 750 detector.
Setup
Battery Installation:
- Remove the back cover of the detector by twisting it counter-clockwise.
- Insert three (3) 1.5V AA batteries into the battery compartment, ensuring correct polarity.
- Replace the back cover by aligning it and twisting clockwise until it clicks securely.
Video: This video demonstrates the product display and installation process, including battery insertion and mounting.

Image: Illustration showing the replaceable 3 AA batteries, highlighting the detector's portability.
Mounting:
- Choose a suitable location for installation, typically near potential gas sources but away from direct drafts or obstructions.
- Use the provided mounting screws to secure the back cover to the wall or ceiling.
- Attach the detector unit to the mounted back cover by aligning and twisting.
Initial Power-On and Self-Test:
- Upon battery installation, the detector will perform an automatic self-test, indicated by a countdown on the LED display and flashing lights.
- Once the self-test is complete, the display will show '0' PPM and the green 'POWER' indicator will light up, signifying normal operation.
Operating Instructions
Normal Operation:
In normal operation, the green 'POWER' indicator light will flash periodically, and the LED display will show '0' PPM (parts per million) for carbon monoxide or '0' LEL (lower explosive limit) for natural gas, indicating no detected gas.

Image: Visual guide to the LED indicators: Green for Normal Status, Red for Alarm Status, Yellow for Product Malfunction.
Alarm Modes:
When gas levels exceed the preset thresholds, the detector will activate audible and visual alarms:
- Audible Alarm: A loud alarm sound exceeding 85dB will be emitted.
- Visual Alarm: The red 'ALERT' indicator light will flash, and the LED display will show the detected gas concentration.
- CO Alarm Threshold: 150 PPM
- CH4 Alarm Threshold: 8% LEL

Image: Depiction of the detector's audible alerts and red light flash during an emergency.
Testing the Detector:
Press the 'TEST/SILENCE' button to initiate a self-test. The alarm will sound, and lights will flash, confirming proper functionality.
Silence Function:
During an alarm, pressing the 'TEST/SILENCE' button will temporarily silence the audible alarm for a short period, allowing you to investigate the source of the gas leak. The visual alerts will continue until the gas concentration drops below the alarm threshold.

Image: Detailed view of the detector, highlighting the display, power, alert, and fault indicators, and the 'TEST/SILENCE' button.
Maintenance
Battery Replacement:
When the batteries are low, the detector may indicate a fault or low battery warning. Replace all three AA batteries promptly to ensure continuous protection. Refer to the 'Battery Installation' section for instructions.
Cleaning:
Regularly clean the exterior of the detector with a soft, damp cloth. Do not use harsh chemicals or abrasive cleaners. Do not paint the detector, as this can interfere with sensor operation.
Sensor Life:
The sensor in this detector has an expected lifespan of 10 years. After this period, the unit should be replaced to ensure continued accuracy and reliability.

Image: Graphic indicating the 10-year product and sensor life of the AOTIQUAL detector.
Troubleshooting
Fault Indication:
If the yellow 'FAULT' indicator light illuminates or the unit beeps intermittently (e.g., every 30-60 seconds) outside of a normal alarm, it indicates a malfunction. This may occur even with new batteries.
- Action: If a fault persists after replacing batteries and re-testing, the unit is faulty and should be replaced immediately. Do not rely on a faulty detector for safety.
False Alarms:
Ensure the detector is not placed near sources of fumes (e.g., cleaning products, paint, strong odors) that could trigger a false alarm. Verify that the detector is not exposed to extreme temperatures or humidity.
Testing with Gas:
To test the gas detection function, use a gas collection bag to release a small amount of carbon monoxide or combustible gas directly into the detector's air intake. Do not use lighters or other open flames, as the high-precision methane sensor is not sensitive to liquefied petroleum gas from lighters and this can damage the unit.

Image: Illustrates the correct method for testing the detector using a gas collection bag and warns against using a lighter.
Specifications
| Brand | AOTIQUAL |
| Model Number | 750 |
| Power Source | Battery Powered (3 x 1.5V AA batteries) |
| Material | ABS |
| Product Dimensions | 3.8"D x 3.8"W x 1.6"H |
| Item Weight | 7.8 ounces |
| Alarm Type | Audible, Visual (LED Display) |
| Operating Humidity | 10%-95% |
| CO Alarm Threshold | 150 PPM |
| CH4 Alarm Threshold | 8% LEL |
| Sensor Life | 10 Years |
Warranty & Support
For warranty information or technical support, please refer to the contact details provided with your purchase or visit the official AOTIQUAL website. Keep your purchase receipt as proof of purchase.