Hitachi RAS.B222PCAIBA1
Contents
Hitachi 2 Ton Fixed Split AC User Manual
Model: RAS.B222PCAIBA1
1. Introduction
Thank you for choosing the Hitachi 2 Ton Fixed Split AC. This manual provides essential information for the safe and efficient operation, installation, and maintenance of your air conditioning unit. Please read this manual thoroughly before using the appliance and keep it for future reference.
This air conditioner is designed to provide comfortable cooling for large-sized rooms (151 sq.ft to 200 sq.ft) with its 2 Ton capacity and features like 4-Way Swing and 24m Long Air Throw.

Image: Front view of the Hitachi Split AC indoor unit, highlighting its sleek design and key features like 4-Way Swing and Odour-free air.
2. Safety Information
Always follow basic safety precautions when using electrical appliances to reduce the risk of fire, electric shock, and injury.
- Ensure the power supply matches the unit's specifications.
- Do not attempt to repair or modify the unit yourself. Contact qualified service personnel.
- Keep the area around the outdoor unit clear of obstructions.
- Do not insert fingers or objects into the air inlet/outlet.
- Ensure proper grounding to prevent electric shock.
- This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
3. Package Contents
Verify that all components are present and undamaged upon unpacking.
- 1 x Indoor Unit
- 1 x Outdoor Unit
- 1 x Inter Connecting Copper Pipe (3m length)
- 1 x Remote Control
- 1 x User Manual with Warranty Card
- 2 x Batteries (for remote control)
- 1 x Drain Pipe
4. Setup and Installation
Installation of this air conditioning unit requires specialized skills and tools. It is strongly recommended that installation be performed by a qualified and certified technician to ensure proper functioning and safety, and to maintain warranty validity.
4.1. Choosing an Installation Location
- Indoor Unit: Select a location that allows for even air distribution throughout the room, away from direct sunlight or heat sources. Ensure sufficient space around the unit for maintenance.
- Outdoor Unit: Choose a well-ventilated area, away from direct sunlight and where the noise will not disturb neighbors. Ensure stable mounting and proper drainage.
4.2. Installation Steps (Overview for Technician)
- Mounting the indoor unit plate.
- Drilling the wall hole for piping.
- Connecting refrigerant pipes and drain hose.
- Wiring connections (indoor to outdoor unit, and power supply).
- Mounting the outdoor unit.
- Vacuuming and charging refrigerant (R32).
- Performing a test run.

Image: Diagram showing the dimensions of both the indoor and outdoor units, along with the energy efficiency guide for planning installation space.
5. Operating Instructions
Your Hitachi AC comes with a remote control for convenient operation. Ensure batteries are inserted correctly.
5.1. Remote Control Functions
- POWER Button: Turns the unit ON/OFF.
- MODE Button: Cycles through operating modes: Cool, Fan, Dry.
- TEMP ▲/▼ Buttons: Adjusts the desired temperature.
- FAN SPEED Button: Adjusts fan speed (Auto, Low, Medium, High).
- SWING Button: Activates or deactivates the 4-Way Swing function for wider air distribution.
- ECO Mode: Optimizes energy consumption for efficient cooling.
- GOOD SLEEP Mode: Adjusts temperature automatically for comfortable sleep.

Image: Illustration demonstrating the 4-Way Swing feature, showing air being dispersed in multiple directions for uniform cooling.

Image: Visual representation of the 24m Long Air Throw, illustrating how the air conditioner can cool larger spaces effectively.

Image: Depiction of the silent operation feature, showing the big blower and wave blade design that reduces air cutting noise.
6. Maintenance
Regular maintenance ensures optimal performance and extends the lifespan of your AC unit. Always disconnect power before performing any maintenance.
6.1. Air Filter Cleaning
- Clean the air filters every two weeks or more frequently if used heavily.
- Open the front panel of the indoor unit and remove the filters.
- Wash filters with lukewarm water and mild detergent. Rinse thoroughly and dry completely before re-installing.
- The Anti-bacterial SuperFine Mesh Filter helps in providing odour-free air.

Image: Illustration of the Auto Coil Dry Technology, which helps in preventing odor by keeping the coil dry after operation.
6.2. Outdoor Unit Maintenance
- Periodically check the outdoor unit for any obstructions (leaves, debris) and clear them.
- Ensure the drainage pipe is not clogged.
- For thorough cleaning of coils and other internal components, it is recommended to schedule professional servicing annually.
7. Troubleshooting
Before contacting service, refer to the following table for common issues and their solutions.
| Problem | Possible Cause | Solution |
|---|---|---|
| Unit does not start | No power supply; Batteries in remote are dead. | Check power connection and circuit breaker; Replace remote batteries. |
| Insufficient cooling | Dirty air filters; Blocked outdoor unit; Room too large; Doors/windows open. | Clean air filters; Clear obstructions; Ensure room size is within capacity; Close doors/windows. |
| Unusual noise | Loose parts; Obstruction in fan; Unit not level. | Contact service technician; Check for obstructions; Ensure unit is level. |
| Water leakage from indoor unit | Clogged drain pipe; Improper installation. | Clear drain pipe; Contact service technician for re-installation check. |
If the problem persists after trying these solutions, please contact Hitachi customer support.
8. Specifications
| Feature | Detail |
|---|---|
| Brand | Hitachi |
| Model Number | RAS.B222PCAIBA1 |
| Capacity | 2 Ton (1.8 Tons as per specifications) |
| Energy Rating | 2 Star |
| Compressor Type | Non-inverter |
| Condenser Coil | 100% Copper |
| Refrigerant Gas | R32 (Environmental Friendly) |
| Air Throw Distance | 24m Long Air Throw |
| Air Flow Control | 4 Way Swing |
| Noise Level (Indoor Unit) | 39 dB |
| Operating Temperature | Works up to 52 Degree C (Tropical Design) |
| Indoor Unit Dimensions (WxHxD) | 105 cm X 29.4 cm X 25 cm |
| Outdoor Unit Dimensions (WxHxD) | 80 cm X 64 cm X 29.8 cm |
| Indoor Unit Weight | 11.4 Kg |
| Outdoor Unit Weight | 41 Kg |
| Special Features | Anti-bacterial SuperFine Mesh Filter, ECO Mode, Good Sleep Mode, Odour-free air (Auto Coil Dry Technology) |
9. Warranty and Support
Your Hitachi AC unit comes with a comprehensive warranty to ensure peace of mind.
- Manufacturer Warranty: 5 Year Comprehensive on Product.
- Compressor Warranty: 10 years on Compressor.
- PCB/Controller Warranty: 5 years on PCB/Controller.
For service requests, technical assistance, or warranty claims, please contact Hitachi Customer Care:
- Customer Care No.: 7567884848
- Email: customercare@jci-hitachi.com
- Manufacturer Address: JCH-IN., Hitachi Complex, Karannagar, Kadi. Dist. Mehsana- 382715. Gujarat. India.
Please retain your purchase receipt and warranty card for future reference.
Documents and downloads
Ask a question about this manual
Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.