OWON SDS210S Digital Oscilloscope User Manual

Model: SDS210S

1. Introduction

This manual provides detailed instructions for the safe and effective operation of your OWON SDS210S Digital Oscilloscope. Please read this manual thoroughly before using the instrument and keep it for future reference.

2. Safety Information

To prevent electric shock or personal injury, and to avoid damage to the instrument or connected equipment, observe the following safety precautions:

  • Use the provided power cord.
  • Connect and disconnect probes properly.
  • Do not operate in wet or damp conditions.
  • Do not operate in explosive atmospheres.
  • Keep product surfaces clean and dry.
  • Refer servicing to qualified personnel.

3. Package Contents

Verify that all items listed below are included in your package. If any items are missing or damaged, please contact your supplier.

  • OWON SDS210S Digital Oscilloscope
  • Power Cord
  • USB Cable
  • Oscilloscope Probes (2)
  • BNC Cable
  • Quick Guide / User Manual
OWON SDS210S Oscilloscope and included accessories
Figure 3.1: OWON SDS210S Digital Oscilloscope with its standard accessories, including power cord, USB cable, probes, BNC cable, and quick guide.

4. Product Overview

4.1 Front Panel Layout

The front panel of the SDS210S features the display, control knobs, buttons, and input/output ports. Familiarize yourself with these components for efficient operation.

Labeled front and rear panel diagram of OWON SDS210S Oscilloscope
Figure 4.1: Detailed diagram showing the front panel controls and rear panel connections of the OWON SDS210S Digital Oscilloscope.
  • 7-inch TFT LCD Display: Provides clear visualization of waveforms and measurement data.
  • Button and Knob Control Area: Dedicated controls for various oscilloscope functions, including vertical, horizontal, trigger, and menu navigation.
  • Oscilloscope Signal Input Ports (CH1, CH2): BNC connectors for connecting probes to measure signals.
  • Signal Generator Output Port: BNC connector for outputting arbitrary waveforms.
  • USB Host Interface: For connecting USB storage devices to save or retrieve data.
  • Probe Compensation Output: Provides a 5V/1kHz signal for probe calibration.

4.2 Rear Panel Layout

The rear panel includes essential connections for power and PC communication.

  • Power Socket: For connecting the power cord.
  • USB Device Interface: Used to connect the oscilloscope to a PC for data transmission and remote control.
  • Ventilation Holes: Ensure proper airflow to prevent overheating.
  • Foldable Handle: For portability and convenient positioning.

4.3 Key Features

  • Dual-channel Oscilloscope with 100MHz Bandwidth and 1GS/s sampling rate.
  • Integrated 25MHz Arbitrary Waveform Signal Generator.
  • FFT Spectrum Analysis for frequency domain signal analysis.
  • 30 Automatic Waveform Measurements, including time, amplitude, and phase values.
  • 6-digit High-precision Frequency Counter.
  • USB Device interface for PC communication, supporting SCPI and LabVIEW functions for remote control and secondary development.
OWON SDS210S highlighting dual-channel oscilloscope and signal generator features
Figure 4.2: Overview of the SDS210S's core capabilities, including 100MHz bandwidth, 1GS/s sampling rate, 20M record length, and 30 automatic measurements.

5. Setup

5.1 Power Connection

  1. Ensure the power switch on the front panel is in the OFF position.
  2. Connect the provided power cord to the power socket on the rear panel of the oscilloscope.
  3. Plug the other end of the power cord into a grounded AC power outlet.

5.2 Probe Connection and Compensation

  1. Connect the oscilloscope probe to one of the input channels (CH1 or CH2) on the front panel.
  2. Attach the probe tip to the Probe Compensation Output (5V/1kHz) on the front panel.
  3. Power on the oscilloscope.
  4. Adjust the probe compensation on the probe itself until a flat-top square wave is displayed on the screen. This ensures accurate measurements.

6. Operating Instructions

6.1 Basic Operation

  1. Power On/Off: Press the power switch on the front panel to turn the instrument on or off.
  2. Channel Selection: Use the CH1 and CH2 buttons to enable or disable input channels.
  3. Vertical Scale (VOLTS/DIV): Adjust the vertical scale knob to change the voltage per division.
  4. Horizontal Scale (SEC/DIV): Adjust the horizontal scale knob to change the time per division.
  5. Trigger Level: Use the Trigger knob to set the trigger level for stable waveform display.

6.2 Waveform Display and Zoom

The 7-inch TFT LCD display allows for clear viewing and detailed analysis of waveforms, including a zoom function.

7-inch TFT LCD display showing waveform zoom function
Figure 6.1: The 7-inch TFT LCD display demonstrating the zoom function for detailed signal observation.

6.3 Signal Generator Function

The SDS210S includes a 25MHz arbitrary waveform generator. To use this function:

  1. Connect a BNC cable from the Signal Generator Output port to your desired load.
  2. Press the "Output" button or navigate through the menu to access the signal generator settings.
  3. Select the desired waveform type (e.g., sine, square, ramp, arbitrary).
  4. Adjust parameters such as frequency, amplitude, and offset using the corresponding controls.
OWON SDS210S showing the 25MHz Arbitrary Waveform Generator output port
Figure 6.2: Close-up view of the 25MHz Arbitrary Waveform Generator output port on the SDS210S.

6.4 FFT Spectrum Analysis

The Fast Fourier Transform (FFT) function allows you to analyze signals in the frequency domain, useful for identifying harmonics, distortion, and noise.

  • Press the "Math" button and select FFT from the menu.
  • Adjust the FFT settings, such as window type and source channel, to optimize the spectrum display.
FFT Spectrum Analysis display on OWON SDS210S
Figure 6.3: Example of FFT spectrum analysis displayed on the oscilloscope screen, converting time-domain signals into frequency components.

6.5 Automatic Waveform Measurements

The SDS210S supports 30 types of automatic measurements, simplifying signal analysis.

  • Press the "Measure" button to display the automatic measurement menu.
  • Select the desired measurements (e.g., Period, Frequency, Vpp, RMS) to be displayed on the screen.
OWON SDS210S displaying 30 automatic waveform measurements
Figure 6.4: Screen showing various automatic waveform measurements, including time, count, delay, phase, and amplitude values.

6.6 PC Communication and Remote Control

The USB Device interface allows connection to a PC for remote control and data transfer, supporting SCPI commands and LabVIEW functions.

OWON SDS210S connected to a laptop for remote control
Figure 6.5: The SDS210S connected to a computer, illustrating its capability for remote control and secondary development via USB.

7. Maintenance

7.1 General Care

  • Cleaning: Clean the instrument's exterior with a soft, damp cloth. Do not use abrasive cleaners or solvents.
  • Storage: Store the oscilloscope in a dry, dust-free environment when not in use.
  • Ventilation: Ensure ventilation holes are clear of obstructions to prevent overheating.

7.2 Calibration

Periodic calibration by qualified personnel is recommended to maintain measurement accuracy.

8. Troubleshooting

This section addresses common issues you might encounter. For problems not listed here, please contact customer support.

  • No Power: Check the power cord connection and the power outlet. Ensure the power switch is ON.
  • No Waveform Display: Verify probe connections, channel selection, and vertical/horizontal scale settings. Adjust the trigger level.
  • Unstable Waveform: Adjust the trigger source, type, and level. Check probe compensation.
  • Incorrect Measurements: Perform probe compensation. Ensure correct measurement settings are selected.

9. Specifications

The following table provides detailed technical specifications for the OWON SDS210S Digital Oscilloscope.

FeatureSpecification (SDS210S)
ModelSDS210S
Access Channels2CH
Bandwidth100MHz
Sampling Rate1GS/s
Storage Depth20M
Vertical Resolution8 bit
Signal Generator1CH (25MHz Arbitrary Waveform)
Package Dimensions14.57 x 7.09 x 4.53 inches
Item Weight3.53 Pounds
ManufacturerOWON
Comparison table of OWON SDS200 series models
Figure 9.1: SDS200 series selection table, showing specifications for SDS210S, SDS215S, and SDS220S models.
Dimensions of the OWON SDS210S Oscilloscope
Figure 9.2: Physical dimensions of the OWON SDS210S: 301mm (length) x 152mm (height) x 70mm (depth).

10. Warranty and Support

OWON products are designed for reliability and performance. For warranty information and technical support, please refer to the official OWON website or contact your local distributor. Keep your purchase receipt as proof of purchase.

Manufacturer: OWON

Date First Available: December 16, 2024

© 2024 OWON. All rights reserved.