1. Introduction
This manual provides essential instructions for the safe and efficient operation of your EJWFASCV IC208CX-11000 Thermostat Temperature Controller. This device is designed for precise temperature regulation in various industrial and machinery applications. Please read this manual thoroughly before installation and use, and retain it for future reference.
2. Safety Information
Always observe the following safety precautions to prevent injury or damage to the device.
- Ensure all electrical connections are made by a qualified professional and comply with local electrical codes.
- Disconnect power before performing any installation, maintenance, or troubleshooting.
- Do not expose the device to excessive moisture, dust, or extreme temperatures outside its operating range.
- Do not attempt to modify or repair the device yourself. Refer all servicing to authorized personnel.
- Verify the power supply voltage matches the device's requirements.
3. Product Overview
The IC208CX-11000 is a compact temperature controller featuring a digital display and intuitive controls for setting and monitoring temperature.

Figure 1: Front View of the IC208CX-11000 Temperature Controller. This image shows the front panel of the EJWFASCV IC208CX-11000 temperature controller, featuring a dual digital display for current and set temperatures, along with control buttons for setting parameters and operating modes. The buttons include 'SET', up/down arrows, and symbols for heating and cooling functions.
Key Components:
- Digital Display: Shows current temperature and set parameters.
- SET Button: Used to enter parameter setting mode.
- Up/Down Buttons: Adjust values and navigate menus.
- Indicator Lights: (If present, describe their function based on visual cues or common controller designs, e.g., for heating/cooling status).
4. Specifications
| Feature | Detail |
|---|---|
| Model Name | IC208CX-11000 |
| Brand | EJWFASCV |
| Package Dimensions | 1.18 x 0.79 x 0.39 inches |
| Item Weight | 1.54 pounds (700 Grams) |
| Manufacturer | EJWFASCV |
| Color | One Color |
| Number of Pieces | 1 |
5. Setup and Installation
The IC208CX-11000 is designed for quick installation, suitable for various industrial applications.
- Mounting: Securely mount the controller in a suitable panel cutout. Ensure adequate ventilation around the unit.
- Wiring: Connect the power supply, temperature sensor, and controlled load (e.g., heater or cooler) to the appropriate terminals on the back of the unit. Refer to the wiring diagram provided with the product packaging for specific connections.
- Sensor Placement: Position the temperature sensor in the environment where temperature control is required, ensuring it accurately reflects the target temperature.
- Power On: After all connections are verified, apply power to the unit. The display should illuminate, showing the current temperature.
6. Operating Instructions
The controller operates based on a pressure switch principle, utilizing internal and external pressure differences to activate or deactivate equipment, thereby maintaining the desired temperature.
Setting the Target Temperature:
- Press the SET button once. The display will show the current set temperature, which may flash.
- Use the Up (▲) and Down (▼) buttons to adjust the target temperature to your desired value.
- Press the SET button again to confirm the setting and exit the setting mode. The display will return to showing the current temperature.
Advanced Settings (Parameter Configuration):
To access advanced parameters (e.g., hysteresis, calibration, operating mode), typically a long press of the SET button or a combination of buttons is required. Refer to the full product manual or manufacturer's website for detailed parameter descriptions and adjustment procedures.
7. Maintenance
Regular maintenance ensures the longevity and reliable operation of your temperature controller.
- Cleaning: Periodically clean the front panel and display with a soft, dry cloth. Do not use abrasive cleaners or solvents.
- Inspection: Regularly inspect wiring connections for looseness or signs of damage. Ensure the temperature sensor is clean and properly positioned.
- Environment: Maintain a clean, dry environment for the controller, free from excessive dust, humidity, and corrosive gases.
8. Troubleshooting
If you encounter issues with your IC208CX-11000, refer to the following common problems and solutions:
| Problem | Possible Cause | Solution |
|---|---|---|
| Display is blank | No power supply; Loose wiring | Check power connections and ensure power is supplied. Verify wiring is secure. |
| Temperature reading is inaccurate | Sensor fault; Incorrect sensor placement; Calibration error | Check sensor connection and integrity. Reposition sensor. Consult advanced settings for calibration. |
| Controller not activating load | Load wiring issue; Set temperature not reached; Controller in wrong mode | Verify load wiring. Adjust set temperature. Check operating mode (heating/cooling). |
| Buttons unresponsive | Temporary software glitch; Physical damage | Power cycle the device. If issue persists, contact support. |
If the problem persists after attempting these solutions, please contact EJWFASCV customer support.
9. Warranty and Support
For warranty information, technical support, or service inquiries regarding your EJWFASCV IC208CX-11000 Temperature Controller, please refer to the warranty card included with your product or visit the official EJWFASCV website. Please have your model number (IC208CX-11000) and purchase details ready when contacting support.