1. Introduction
The Protmex PTH-26PM Air Quality Monitor is a portable device designed to provide real-time measurements of air quality parameters. It features sensors for PM2.5 and PM10 particulate matter, as well as integrated temperature and humidity sensors. This manual provides detailed instructions for the proper use and maintenance of your device.
2. Product Overview
2.1 Key Features

- 3-in-1 Air Quality Detection: Monitors PM2.5, PM10, temperature, and humidity.
- High-Precision Sensors: Equipped with accurate sensors for particulate matter detection, ranging from 0 to 1000 µg/m³ with 1 µg/m³ resolution.
- Buzzer Alert System: Provides immediate notifications when air pollution levels reach concerning thresholds.
- Large LCD Display: Offers clear and crisp visibility of air quality data.
- Portable Design: Compact and lightweight for easy transport and use in various environments.
- Long Battery Life: Features a 1000mAh Lithium-Ion battery for extended operation.
2.2 Device Components

The device features a clear LCD display for real-time readings and three control buttons for operation. Air inlets are located on both sides for accurate detection.
3. Setup
3.1 Unpacking
Carefully remove the Protmex PTH-26PM Air Quality Monitor and all accessories from the packaging. Verify that all items listed in the "What's in the Box" section are present.
3.2 Charging the Device
Before initial use, fully charge the device. Connect the provided USB cable to the charging port on the monitor and plug the other end into a standard USB power adapter (not included) or a computer's USB port. The battery indicator on the display will show charging status. A full charge typically takes a few hours.
4. Operating Instructions
4.1 Powering On/Off
To power on the device, press and hold the central button until the display illuminates. To power off, press and hold the central button again until the display turns off.
4.2 Real-Time Monitoring
Upon powering on, the device will immediately begin monitoring air quality. The large LCD display will show real-time readings for:
- PM2.5: Particulate matter 2.5 micrometers or less in diameter (µg/m³).
- PM10: Particulate matter 10 micrometers or less in diameter (µg/m³).
- Temperature: Ambient temperature (in Celsius or Fahrenheit, depending on settings).
- Humidity: Relative humidity percentage.

4.3 Buzzer Alert System
The device is equipped with a buzzer alert system that activates when detected air pollution levels exceed predefined thresholds. This provides an immediate audible warning. Refer to the device settings (if available) to adjust or disable the buzzer.

4.4 Navigation and Settings (if applicable)
Use the up and down arrow buttons (if present) to navigate through different display modes or settings menus. The central button typically acts as a selection or confirmation button. Consult the on-screen prompts for specific navigation instructions.
5. Maintenance
5.1 Cleaning
To maintain optimal performance, keep the device clean. Wipe the exterior with a soft, dry cloth. Do not use abrasive cleaners or solvents. Ensure the air inlets on the sides are free from dust and debris. Do not attempt to clean the internal sensors directly.
5.2 Storage
When not in use for extended periods, store the device in a cool, dry place, away from direct sunlight and extreme temperatures. Ensure the battery is partially charged before storage to prolong its lifespan.
6. Troubleshooting
- Device does not power on:
Ensure the device is fully charged. Connect it to a power source using the USB cable and allow it to charge for at least 30 minutes before attempting to power it on again. If the issue persists, the battery may be defective.
- Inaccurate readings:
Ensure the air inlets on the sides of the device are not obstructed by dust or debris. Operate the device in a stable environment, away from strong air currents or direct sources of pollution (e.g., smoke, sprays) that could skew readings temporarily. Allow the device a few minutes to stabilize after powering on.
- Display issues (e.g., blank screen, distorted image):
Try restarting the device. If the problem persists, it may indicate a hardware malfunction. Contact customer support for assistance.
- Buzzer alarm sounds unexpectedly:
Check the current air quality readings on the display. The alarm indicates that pollution levels have exceeded the set thresholds. If the readings appear normal and the alarm continues, there might be a sensor issue. Refer to the device settings to adjust or temporarily disable the alarm if needed.
7. Specifications

| Parameter | Value |
|---|---|
| Product Name | PM2.5/PM10 Detection |
| Product Model | PTH-26PM |
| Product Size | 105 x 52 x 24 mm |
| Measuring Range | PM2.5/PM10: 0–1000 µg/m³ |
| Display Resolution | PM2.5/PM10: 1 µg/m³ |
| Battery Specification | Li-Po (1000mAh) |
| Working Temperature | -10°C to 50°C / 14°F to 122°F |
| Package Dimensions | 4.29 x 2.09 x 1.54 inches |
| Weight | 3.84 ounces |
8. What's in the Box
- Protmex PTH-26PM Air Quality Monitor
- USB Cable
- User Manual (this document)
9. Warranty and Support
For warranty information or technical support, please refer to the contact details provided with your purchase documentation or visit the official Protmex website. Keep your purchase receipt as proof of purchase.