LP8000

Generic LP8000 Peristaltic Pump User Manual

Model: LP8000-S82T (8000ml/min)-12V

1. Introduction

This manual provides instructions for the safe and efficient operation, installation, and maintenance of the Generic LP8000 Peristaltic Pump. Please read this manual thoroughly before using the pump to ensure proper function and to prevent damage or injury.

The LP8000 series peristaltic pump is designed for precise dispensing of various liquids, including food, beverages, cooking oil, and propanol. Its design features a card slot upgrade for easy tube changes and a robust motor for reliable performance.

2. Safety Information

Always observe the following safety precautions:

  • Ensure the pump is connected to the correct voltage supply (12V or 24V DC) as specified for your model.
  • Do not operate the pump with damaged tubing or electrical components.
  • Keep the pump away from excessive heat, moisture, and corrosive environments.
  • Disconnect power before performing any maintenance or tube changes.
  • This pump is designed for specific fluid types. Ensure compatibility with the liquid being dispensed.

3. Product Overview

The LP8000 peristaltic pump features a compact design with a transparent shell for visible operation. Key components include the motor, pump head with rollers, and replaceable tubing.

LP8000 Peristaltic Pump Front View

Figure 1: Front view of the LP8000 Peristaltic Pump, showing the transparent cover and tubing connections.

LP8000 Peristaltic Pump Internal Mechanism

Figure 2: Internal view of the LP8000 pump head, illustrating the rollers and tubing path.

Model Interpretation

Understanding the model number helps identify specific pump configurations:

LP8000 Model Interpretation Diagram

Figure 3: Diagram explaining the LP8000 model numbering system, including motor voltage, tube type (Silicone or Norprene), and installation mode.

  • LP8000: Base model series.
  • D12/D24: Indicates motor voltage (12V DC or 24V DC).
  • S/N: Specifies tube material (S for Silicone, N for Norprene).
  • 73T/82T: Denotes tube size and flow rate characteristics.
  • A: Refers to the installation mode.

4. Setup

Installation

The LP8000 pump is designed for easy integration. Refer to the installation diagram for mounting dimensions and procedures.

LP8000 Installation Diagram

Figure 4: Detailed installation diagram showing dimensions and mounting points for the LP8000 pump (Type A installation).

  1. Identify a suitable mounting location that is stable, dry, and provides adequate ventilation.
  2. Use the provided dimensions to mark drilling points for mounting screws. The pump is equipped with M5x20 upper screws.
  3. Securely attach the pump to the mounting surface.
  4. Connect the inlet and outlet tubing to your fluid source and destination. Ensure all connections are secure to prevent leaks.
  5. Connect the pump to the appropriate 12V or 24V DC power supply. Verify the voltage matches your pump model.

5. Operating Instructions

Once installed and connected, the LP8000 pump is ready for operation.

  1. Ensure the fluid path is clear and the tubing is correctly seated in the pump head.
  2. Apply power to the pump. The transparent shell allows for visual confirmation of the rollers' operation.
  3. Monitor the fluid flow. The pump is designed for stable and smooth operation.
  4. To stop operation, disconnect the power supply.

Flow Rate Information

The flow rate depends on the tube species and voltage. Refer to the table below for typical flow rates:

LP8000 Flow Rate Table

Figure 5: Table detailing flow rates (ml/min) for different tube species (S73T, S82T, N73T) at 12V and 24V.

LP8000 Peristaltic Pump Flow Rates
ParameterS73T (Silicone)S82T (Silicone)N73T (Norprene)
Tube ID×OD9.6×16 mm12.7×19.1 mm9.6×16 mm
Flow rate (12V, 2.5A)5800 ml/min8000 ml/min5000 ml/min
Flow rate (24V, 1.5A)5800 ml/min8000 ml/min5000 ml/min

Note: Ideal working conditions are ambient temperature 0-50 degrees Celsius, relative humidity less than 80%.

6. Maintenance

Regular maintenance ensures the longevity and optimal performance of your LP8000 pump.

Tubing Replacement

The pump tube is a consumable part and should be replaced periodically depending on usage and fluid type. The card slot design facilitates easy replacement.

  1. Disconnect the pump from the power supply.
  2. Open the pump head cover (if applicable) or access the tubing area.
  3. Carefully remove the old tubing from the card slots and roller mechanism.
  4. Insert the new tubing, ensuring it is properly seated in the card slots and around the rollers. The tight fit and small roller gap are designed to prevent tube running and ensure high precision.
  5. Close the pump head cover (if applicable) and reconnect power.

Cleaning

The waterproof pump head allows for easy cleaning.

  • Disconnect power before cleaning.
  • Wipe the exterior of the pump with a damp cloth. Avoid using harsh chemicals that may damage the plastic components.
  • For internal cleaning, flush the tubing with an appropriate cleaning solution compatible with the tubing material and the fluids previously dispensed.
  • Ensure the pump and tubing are dry before resuming operation.

7. Troubleshooting

If you encounter issues with your LP8000 pump, refer to the following common problems and solutions:

Troubleshooting Guide
ProblemPossible CauseSolution
Pump does not startNo power supply; Incorrect voltage; Motor fault.Check power connection; Verify voltage matches pump specification; Contact support if motor is faulty.
No fluid flow or reduced flowTubing kinked or blocked; Worn tubing; Air in the line; Incorrect tube seating.Inspect and clear tubing; Replace worn tubing; Prime the pump to remove air; Re-seat tubing correctly.
Excessive noise during operationWorn rollers or bearings; Improper installation; Tubing not properly seated.Check for loose components; Ensure proper installation; Verify tubing is correctly seated; Contact support for internal component issues.
Leakage from pump headDamaged tubing; Improperly installed tubing; Loose connections.Replace damaged tubing; Re-install tubing correctly; Tighten all connections.

8. Specifications

Detailed technical specifications for the LP8000 Peristaltic Pump:

  • Model Number: LP8000
  • Power Source: Electric (DC Motor)
  • Voltage: 12V or 24V (model dependent)
  • Power: 72W
  • Reduction Ratio: 1:10
  • Outlet Size: 9.6mm (for S73T/N73T), 12.7mm (for S82T)
  • Material: PA66+PC (pump housing)
  • Flow Rate: 5000-8000 ml/min (model dependent)
  • Lifetime: 1500H
  • Dimensions (L x W x H): 188.6 x 99.8 x 128.5 mm (7.43 x 3.93 x 5.06 inches)
  • Weight: 0.95 kg (2.09 lbs)
  • Certifications: CE, ROHS, ISO9001
  • Included Components: 1 pump with motor (squeezing tubing and bard fittings equipped)

9. Warranty

This LP8000 Peristaltic Pump comes with a 1-year warranty from the date of purchase. The warranty covers manufacturing defects and material faults under normal use conditions. It does not cover damage resulting from misuse, unauthorized modifications, or improper installation.

Please retain your proof of purchase for warranty claims.

10. Support

For technical assistance, troubleshooting beyond this manual, or warranty inquiries, please contact your retailer or the manufacturer directly.

Manufacturer: foreshine fluid

Please have your model number (LP8000) and purchase details ready when contacting support.

© 2026 Generic. All rights reserved.