1. Introduction
Thank you for choosing the biaodibisizs A066 Furnace Draft Inducer Flue Exhaust Blower. This manual provides essential information for the safe and efficient installation, operation, and maintenance of your new unit. Please read these instructions thoroughly before beginning installation or operation and retain this manual for future reference.
2. Safety Information
WARNING: Improper installation, adjustment, alteration, service, or maintenance can cause property damage, injury, or death. Read these instructions completely before installing or servicing this equipment.
- Always disconnect power to the furnace before installing or servicing the draft inducer blower.
- Wear appropriate personal protective equipment, including gloves and eye protection, during installation and maintenance.
- Ensure all electrical connections are secure and comply with local electrical codes.
- Do not operate the blower if it is damaged or not functioning correctly.
- This unit must be installed by a qualified service technician.
3. Package Contents
Verify that all components are present before beginning installation:
- 1 x biaodibisizs A066 Furnace Draft Inducer Flue Exhaust Blower
- Gasket (attached to housing)
4. Setup and Installation
This draft inducer blower is a replacement part compatible with various Fasco, Rheem, and Rudd furnace models. Please confirm that the model you need to buy matches our model before ordering. Refer to the specifications section for a list of compatible part numbers.
4.1 Pre-Installation Checks
- Power Disconnection: Ensure the main power supply to the furnace is completely disconnected at the circuit breaker or fuse box.
- Old Unit Removal: Carefully disconnect the wiring and remove the existing draft inducer blower from the furnace. Note the orientation and wiring connections for proper reinstallation.
- Compatibility Check: Compare the new A066 blower with the old unit and the furnace's specifications to ensure proper fit and function. This unit features 1-Speed CCW Rotation and Sleeve Bearings.
4.2 Installation Steps
- Positioning: Align the new A066 draft inducer blower with the mounting points on the furnace. The gasket is pre-attached to the housing for a secure seal.
- Mounting: Secure the blower to the furnace using the appropriate fasteners. Ensure it is firmly attached and there are no gaps around the gasket.
- Wiring: Connect the electrical wiring to the new blower. Refer to the wiring diagram of your furnace and ensure connections match the original setup. Double-check all connections for tightness and proper insulation.
- Vent Pipe Connection: Reconnect the flue vent pipe to the blower outlet. Ensure a tight, leak-free connection.
- Final Inspection: Visually inspect all connections, mounting, and wiring to ensure everything is correctly installed and secure.

Image 1: The biaodibisizs A066 Furnace Draft Inducer Flue Exhaust Blower. This image shows the overall design and components of the blower, including the motor and housing, which is crucial for identifying the correct replacement part during installation.
5. Operating Instructions
Once installed, the draft inducer blower operates automatically as part of the furnace's combustion cycle. When the thermostat calls for heat, the furnace control board activates the draft inducer to create a negative pressure in the combustion chamber, drawing in fresh air and expelling exhaust gases. The furnace will not ignite until the pressure switch confirms proper draft.
- After installation, restore power to the furnace.
- Set the thermostat to call for heat to initiate a test cycle.
- Observe the blower's operation. It should start smoothly and run quietly.
- Listen for any unusual noises or vibrations.
6. Maintenance
Regular maintenance ensures the longevity and efficient operation of your draft inducer blower. Always disconnect power before performing any maintenance.
- Annual Inspection: Have a qualified technician inspect the blower annually for signs of wear, corrosion, or damage.
- Cleaning: Periodically inspect the blower wheel for debris accumulation (e.g., dust, lint). If necessary, carefully clean the wheel and housing using a soft brush or vacuum cleaner. Avoid using harsh chemicals.
- Vibration Check: Ensure the blower remains securely mounted and free from excessive vibration. Tighten any loose fasteners.
7. Troubleshooting
If you experience issues with your draft inducer blower, refer to the table below for common problems and solutions. For complex issues, contact a qualified HVAC technician.
| Problem | Possible Cause | Solution |
|---|---|---|
| Blower does not start | No power; faulty wiring; seized motor; faulty control board | Check power supply and circuit breaker. Verify wiring connections. Inspect motor for obstructions. Consult a technician for control board issues. |
| Blower runs but furnace does not ignite | Pressure switch issue; clogged flue; faulty igniter | Check pressure switch hose for blockages. Inspect flue for obstructions. Consult a technician for igniter issues. |
| Unusual noise or vibration | Loose mounting; debris in blower wheel; worn bearings | Tighten mounting bolts. Clean blower wheel. If bearings are worn, replacement may be necessary. |
| Blower cycles on and off rapidly | Pressure switch malfunction; restricted airflow | Inspect pressure switch and its hose. Check flue and air intake for blockages. |
8. Specifications
The biaodibisizs A066 is designed as a functional equivalent replacement for various furnace draft inducer models.
| Feature | Detail |
|---|---|
| Model Number | A066 |
| Voltage | 115 Volts |
| Amperage | 1.27 Amps |
| Horsepower (HP) | 1/30 hp |
| RPM | 3000 RPM |
| Rotation | CCW (Counter-Clockwise) |
| Bearings | Sleeve Bearings |
| Gasket | Attached to housing |
| Compatible Part Numbers | 70-24157-03, 117847-00, 7058-1406, 70-22838-02, J238-150-1533, J238-150-15165, 70-101087-01, 70-24178-01, 70-24175-01, 70-24175-81, 7021-11559, 70-22838-82, Amtek 117104-01, 117104-04, 117847-07, 66847, 66838, 119243-000, 00-81R02QJAA, 70-24121-03, 70-24151-83, 117104-05, FB-RFB241 |
9. Warranty Information
This product is manufactured with 100% quality assurance, designed and crafted to be a reliable replacement part. It is made of durable, high-quality materials, compact and sturdy, built to last.
10. Customer Support
Customer satisfaction is our priority. If you have any questions, concerns, or are not satisfied with the product, please contact the seller or manufacturer directly for assistance. We are committed to providing a satisfactory solution.