1. Product Overview
The FOTING In/Above Ground Pool Pump is a self-priming, dual-speed pump designed for efficient water circulation in various swimming pools. Equipped with a robust 2HP copper wire motor, it offers a flow rate of up to 3170 GPH (low speed) and 7000 GPH (high speed), with a maximum head lift of 69 feet. This pump features thermal overload protection for enhanced safety and longevity, and includes a removable filter basket and drain plug for easy maintenance. It is suitable for both above-ground and in-ground pool applications, as well as water parks, bathing pools, hot tubs, spas, and irrigation systems.

Figure 1: FOTING In/Above Ground Pool Pump with included 1.5" and 2" NPT inlet connectors and waterproof tape.
2. Safety Information
Please read and understand all safety instructions before installation and operation. Failure to follow these instructions may result in electric shock, fire, or serious injury.
- Always disconnect power to the pump before performing any service or maintenance.
- Ensure the electrical supply matches the pump's voltage requirements (230V).
- The pump must be installed by a qualified electrician in accordance with all local and national electrical codes.
- Do not operate the pump if the power cord is damaged.
- Keep children and unauthorized persons away from the pump during operation.
- The pump is equipped with thermal overload protection. If the pump stops unexpectedly, allow it to cool down before attempting to restart. Investigate potential causes such as clogs or insufficient water flow.
3. Setup and Installation
Proper installation is crucial for the pump's performance and longevity. The pump is self-priming, but proper plumbing connections are essential.
3.1 Unpacking and Inspection
- Carefully remove all components from the packaging.
- Verify that all parts are present: pump unit, two 1.5" NPT inlet adapters, two 2" NPT inlet adapters, and waterproof tape.
- Inspect the pump for any visible damage that may have occurred during shipping. Do not install if damaged.
3.2 Placement
- Place the pump on a solid, level surface near the pool.
- Ensure adequate ventilation around the motor.
- Position the pump to minimize the length of suction and discharge piping.
3.3 Plumbing Connections
The FOTING pump supports two methods for water pipe connection using the included 1.5" and 2" NPT inlet adapters.

Figure 2: Two methods for connecting water pipes to the pump, utilizing 1.5-inch and 2-inch PVC pipe adapters.
- Method 1: Direct PVC Pipe Connection
Connect 1.5" or 2" PVC pipes directly to the pump's inlet and outlet ports using the appropriate adapters and waterproof tape for a secure, leak-free seal. - Method 2: Flexible Hose Connection
Utilize the provided adapters to connect flexible hoses (1.5" or 2") to the pump. Ensure hose clamps are used for a tight connection. - Ensure all connections are sealed properly to prevent air leaks, which can affect pump priming and efficiency.
3.4 Electrical Connection
This pump operates on 230V. A power cord is not included and must be wired by a qualified electrician according to local electrical codes.
- Ensure the power supply is off before making any electrical connections.
- Connect the pump to a dedicated circuit with appropriate overcurrent protection.
- Verify correct voltage and amperage ratings.
4. Operation
The FOTING pool pump features dual-speed operation, allowing you to optimize performance and energy consumption.
4.1 Priming the Pump
- Before initial startup, ensure the pump is filled with water through the skimmer or by removing the transparent lid and filling the filter basket housing.
- Close all drain valves and ensure the pool water level is above the skimmer.
- Once filled, replace the lid securely. The pump's self-priming capability will then quickly establish water flow.
4.2 Dual Speed Control
The pump offers two operating speeds: High and Low. A switch located at the bottom of the motor allows you to select the desired speed.

Figure 3: High Speed mode provides 7000 GPH for rapid water circulation and daytime use.
- High Speed (7000 GPH): Ideal for faster filtration, cycling the entire pool volume quickly, and during periods of heavy use or when cleaning the pool.

Figure 4: Low Speed mode provides 3170 GPH for energy saving and quieter operation during off-peak hours.
- Low Speed (3170 GPH): Recommended for energy saving, quieter operation, and maintaining filtration during less active periods or overnight.
Adjust the speed based on your pool's size, filtration requirements, and desired energy consumption.
5. Maintenance
Regular maintenance ensures optimal performance and extends the lifespan of your FOTING pool pump.
5.1 Cleaning the Filter Basket
The pump is equipped with a removable filter basket to capture debris. The transparent lid allows for easy visual inspection.

Figure 5: The extra-large filter basket effectively collects leaves, twigs, and gravel, and is easily removable for cleaning.
- Turn off the pump and disconnect power.
- Unscrew the transparent lid counter-clockwise.
- Remove the filter basket and empty any collected debris.
- Rinse the basket thoroughly with water.
- Inspect the O-ring on the lid for cracks or wear; replace if necessary.
- Place the clean basket back into the pump and securely fasten the lid.
5.2 Draining the Pump
The integrated drain plug allows for easy water drainage, particularly useful for winterization or extended periods of non-use.

Figure 6: Overview of pump features including the drain plug for easy water removal and the transparent cover for filter basket visibility.
- Turn off the pump and disconnect power.
- Locate the drain plug at the bottom of the pump housing.
- Unscrew the drain plug to allow water to exit the pump.
- Once drained, replace the plug securely.
6. Troubleshooting
This section provides solutions to common issues you may encounter with your FOTING pool pump.
| Problem | Possible Cause | Solution |
|---|---|---|
| Pump does not start | No power supply Thermal overload activated Motor issue | Check power connection and circuit breaker. Allow pump to cool down; check for clogs. Contact customer support if problem persists. |
| Pump runs but no water flow | Pump not primed Air leak in suction line Clogged filter basket/impeller | Ensure pump is filled with water. Check all suction line connections for tightness. Clean filter basket; inspect impeller for debris. |
| Reduced water flow | Clogged filter basket Partially blocked plumbing Low pool water level | Clean filter basket. Inspect and clear plumbing lines. Ensure pool water level is adequate. |
| Excessive noise | Air leak Debris in impeller Motor bearing wear | Check suction line for air leaks. Clean impeller. Contact customer support. |
7. Specifications
Detailed technical specifications for the FOTING In/Above Ground Pool Pump.
| Attribute | Value |
|---|---|
| Brand | FOTING |
| Model Number | J11502-Dual Speed-230V |
| Style | 2HP Dual Speed-230V |
| Color | Black&blue |
| Material | Thermoplastic |
| Product Dimensions (L x W x H) | 25.5" x 7.8" x 11" |
| Item Weight | 37 pounds |
| Power Source | AC |
| Voltage | 230 Volts |
| Maximum Flow Rate | 116 Gallons Per Minute (7000 GPH) |
| Maximum Lifting Height | 69 Feet |
| Motor Type | Copper Wire Motor |
| Protection | Thermal Overload Protection |

Figure 7: Performance curve illustrating the relationship between head lift and flow rate for both high and low speeds.
8. Warranty and Support
FOTING provides a THREE-YEAR after-sale service for this product.
If you encounter any problems or have questions regarding your FOTING pool pump, please contact our customer support team for assistance. Refer to your purchase documentation for specific contact details or visit the official FOTING website.