1. Introduction
The DRUMMOND 750 GPH Drill Pump is a compact and efficient tool designed for quick water transfer tasks. This self-priming pump connects to any standard power drill, making it ideal for draining sinks, aquariums, small ponds, and handling various emergency water removal situations. Its robust thermoplastic construction ensures durability, while the 3/4 inch connections fit standard garden hoses for easy setup.
This manual provides essential information for the safe and effective use of your drill pump. Please read it thoroughly before operation and retain it for future reference.

Image 1.1: The DRUMMOND 750 GPH Drill Pump, showcasing its compact design for various water transfer applications.
2. Safety Information
Always observe the following safety precautions to prevent injury or damage to the pump:
- Personal Protective Equipment: Always wear appropriate safety glasses and gloves during operation.
- Secure Connections: Ensure all hose connections and the drill attachment are tight and secure before starting the pump. Loose connections can lead to leaks or detachment.
- Liquid Compatibility: This pump is designed for water transfer only. Do not use it with flammable liquids, corrosive chemicals, or liquids containing abrasive particles.
- Electrical Safety: Ensure your power drill is in good working condition and properly grounded. Avoid operating the pump in standing water or extremely wet conditions where electrical hazards may be present.
- Supervision: Keep children and pets away from the operating area. Never leave the pump unattended while in use.
- Overheating: Do not run the pump dry for extended periods, as this can cause overheating and damage.
- Temperature Limits: Do not pump liquids hotter than 120°F (49°C).
3. Package Contents
Verify that all components are present in the package:
- DRUMMOND 750 GPH Drill Pump (1 unit)
4. Setup
Follow these steps to set up your DRUMMOND 750 GPH Drill Pump:
- Attach to Drill: Insert the pump's drive shaft into the chuck of your power drill. Tighten the drill chuck securely to prevent slippage during operation.
- Connect Inlet Hose: Attach a standard 3/4 inch garden hose to the inlet port of the pump. This hose will draw water from your source. Ensure the connection is hand-tight to prevent leaks.
- Connect Outlet Hose: Attach another standard 3/4 inch garden hose to the outlet port of the pump. This hose will direct the water to your desired discharge location. Ensure this connection is also hand-tight.
- Position Hoses: Place the inlet hose into the water source you wish to drain. Position the outlet hose to direct the water to a suitable discharge area, ensuring it is not creating a new hazard.

Image 4.1: The drill pump securely attached to a power drill, ready for hose connections.

Image 4.2: Proper connection of inlet and outlet hoses to the drill pump.
5. Operating Instructions
The DRUMMOND 750 GPH Drill Pump is self-priming up to 12 feet, simplifying the startup process.
- Prime the Pump: For optimal performance, ensure the pump housing is filled with water before starting, especially if the lift height is significant. The self-priming feature will draw water, but pre-filling can speed up the process.
- Start the Drill: With all connections secure and hoses positioned, slowly start your power drill. Gradually increase the drill speed to achieve the desired flow rate. The pump operates most efficiently at higher RPMs, up to 2800 RPM.
- Monitor Flow: Observe the water flow from the outlet hose. If no water flows after a short period, stop the drill and check for blockages, kinks in hoses, or air leaks in the inlet connection.
- Continuous Operation: Maintain a steady drill speed for continuous pumping. Avoid running the pump dry for extended periods.
- Stopping Operation: When finished, slowly decrease the drill speed and then turn off the drill. Disconnect the hoses and drill.
6. Maintenance
Proper maintenance ensures the longevity and performance of your drill pump:
- Cleaning: After each use, flush the pump with clean water to remove any debris or residue. This is especially important if pumping dirty water.
- Inspection: Regularly inspect the pump for any signs of wear, cracks, or damage to the housing or connections.
- Storage: Store the pump in a clean, dry place away from direct sunlight and extreme temperatures. Ensure all water is drained from the pump before storage to prevent freezing damage.
7. Troubleshooting
If you encounter issues with your drill pump, refer to the following common problems and solutions:
| Problem | Possible Cause | Solution |
|---|---|---|
| Pump does not prime or flow water | Loose inlet hose connection; Inlet hose not submerged; Air leak in system; Pump running dry for too long. | Tighten all connections; Ensure inlet hose is fully submerged; Check for cracks or damage in hoses; Pre-fill pump with water. |
| Low flow rate | Drill speed too low; Kinked or obstructed hoses; Debris in pump or hoses. | Increase drill speed; Straighten hoses and remove obstructions; Clean pump and hoses. |
| Pump making excessive noise | Running dry; Debris inside pump. | Ensure pump is submerged and primed; Disassemble and clean pump if necessary. |
| Water leaking from connections | Loose hose connections; Damaged hose washers. | Tighten connections; Replace worn hose washers. |
8. Specifications
Technical details for the DRUMMOND 750 GPH Drill Pump:
- Model Number: 56847
- Flow Rate: 750 Gallons Per Hour (GPH) / 12.5 Gallons Per Minute (GPM)
- Maximum RPM: 2800 RPM (Drill dependent)
- Inlet/Outlet Size: 3/4 inch Garden Hose Thread
- Self-Priming Height: Up to 12 feet
- Material: Thermoplastic
- Item Weight: Approximately 9.12 ounces
- Power Source: Power Drill (not included)
- Maximum Liquid Temperature: 120°F (49°C)
9. Warranty & Support
For warranty information or technical support, please refer to the retailer or manufacturer's official website. Keep your purchase receipt as proof of purchase.