Introduction
This manual provides essential information for the safe and effective use of your Sinocare Safe-Accu2 Blood Sugar Test Kit. Please read it thoroughly before using the device for the first time and keep it for future reference.

Image: Complete Sinocare Safe-Accu2 Blood Sugar Test Kit, showing the meter, test strips, lancets, lancing device, and carrying case.
Safety Information
Always follow basic safety precautions when using this product to reduce the risk of injury or damage. This device is intended for in vitro diagnostic use only. Do not use for diagnosis of diabetes without consulting a healthcare professional.
- Keep the device and all accessories out of reach of children.
- Use only Sinocare Safe-Accu2 test strips and lancets with this meter. Incompatible components may lead to inaccurate results.
- Do not use expired test strips. Check the expiration date on the vial.
- Dispose of used lancets and test strips properly in a sharps container.
- Consult your healthcare professional for interpretation of results and for any medical concerns.

Image: Visual guide demonstrating the correct pairing of the Safe-Accu2 meter with its specific test strips, and highlighting incompatibility with other Sinocare meter models.
Package Contents
The Sinocare Safe-Accu2 Blood Sugar Test Kit (Model: New-WYset-25) typically includes the following items:
- 1 x Sinocare Safe-Accu2 Glucometer
- 25 x Safe-Accu2 Test Strips
- 25 x Sterile Lancets
- 1 x Lancing Pen (Lancing Device)
- 1 x PU Bag (Carrying Case)
- 1 x User Manual (This document)
- 2 x AAA Batteries (included)
Product Overview and Features
The Sinocare Safe-Accu2 Blood Sugar Monitor is designed for convenient and accurate blood glucose testing. Key features include:
- No Coding Required: The meter automatically sets the correct code, simplifying the testing process.
- Tiny Blood Sample: Requires only 0.6µl of blood, making daily testing less painful.
- Rapid Results: Provides accurate results in approximately 10 seconds.
- Large Numeric Display: Easy to read results clearly.
- 200 Memory Capacity: Stores up to 200 test results with date and time, allowing for tracking of blood glucose trends.
- Automatic Strip Ejection: Easily discard used test strips without direct handling.
- Automatic Turn Off: Saves battery power by automatically turning off when not in use.
- Portable Design: Compact and lightweight with a convenient carrying case.

Image: Diagram illustrating the key features of the Safe-Accu2 meter, such as no coding, small blood sample volume, large display, and memory capacity.

Image: Visual representation of additional features like automatic strip ejection, auto power-off, and the portability offered by the carry case.
Setup
1. Installing Batteries
The Sinocare Safe-Accu2 meter uses 2 AAA batteries. These are typically included in the package.
- Locate the battery compartment on the back of the meter.
- Open the battery cover.
- Insert two AAA batteries, ensuring correct polarity (+/-).
- Close the battery cover securely.
2. Setting Up the Lancing Device
- Unscrew the cap of the lancing device.
- Insert a new sterile lancet firmly into the lancet holder.
- Twist off the protective cap of the lancet.
- Replace the lancing device cap.
- Adjust the penetration depth by rotating the top of the lancing device. Start with a shallower setting (e.g., 2-3) and adjust as needed for a sufficient blood sample.
- Pull back the cocking control until it clicks, indicating it is ready to use.
Operating Instructions
Follow these steps to perform a blood glucose test:
- Prepare Your Hands: Wash your hands thoroughly with warm water and soap, then dry them completely. This helps ensure hygiene and promotes blood flow.
- Prepare the Meter: Insert a new Sinocare Safe-Accu2 test strip into the test strip port of the meter. The meter will automatically turn on and display a blood drop symbol, indicating it is ready for a blood sample.
- Obtain Blood Sample: Place the lancing device firmly against the side of your fingertip (avoiding the very center) and press the release button. Gently massage your finger to form a small, round drop of blood.
- Apply Blood Sample: Touch the tip of the test strip to the blood drop. The blood will be drawn into the strip automatically. Do not apply blood to the top of the strip.
- Read Results: The meter will begin a countdown (approximately 10 seconds) and then display your blood glucose result.
- Discard Used Components: Eject the used test strip from the meter (the meter has an automatic ejection feature). Carefully remove the used lancet from the lancing device and dispose of both in a sharps container.

Image: Detailed visual steps for performing a blood glucose test using the Sinocare Safe-Accu2 kit.
Memory and Data Management
The Sinocare Safe-Accu2 meter stores up to 200 blood glucose test results with date and time. To review past results:
- With the meter off, press the 'M' button (usually the middle button) to enter memory mode.
- Use the arrow buttons to scroll through previous test results.
- The meter may also display 7, 14, and 28-day average results.
Maintenance
Cleaning the Meter
Clean the meter regularly to ensure proper function and hygiene.
- Wipe the exterior of the meter with a soft, damp cloth.
- A mild detergent or 75% alcohol solution can be used for disinfection.
- Do not immerse the meter in water or any other liquid.
- Ensure no liquid enters the test strip port or battery compartment.
Storage
- Store the meter and test strips in their original carrying case in a cool, dry place.
- Avoid direct sunlight, extreme temperatures, and high humidity.
- Keep test strip vials tightly closed after removing a strip to prevent moisture exposure.
- Do not refrigerate test strips.
Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| Meter does not turn on. | Batteries are dead or incorrectly inserted. | Check battery polarity or replace with new AAA batteries. |
| Error message displayed. | Test strip inserted incorrectly, insufficient blood sample, or expired strip. | Ensure strip is fully inserted. Re-test with a new strip and sufficient blood. Check strip expiration date. |
| Inaccurate results. | Expired test strips, improper storage, dirty meter, or incorrect testing procedure. | Use fresh, unexpired strips. Store strips properly. Clean the meter. Review operating instructions carefully. If issues persist, contact customer support. |
| No blood sample obtained. | Lancing device depth too shallow, or insufficient blood flow. | Increase lancing depth setting. Warm hands and massage finger to improve blood flow. |
Specifications
| Parameter | Detail |
|---|---|
| Model Name | Safe-Accu2 |
| Test Range | 20-600 mg/dL (1.1-33.3 mmol/L) |
| Blood Sample Volume | 0.6 µL |
| Test Time | 10 seconds |
| Memory Capacity | 200 test results with date & time |
| Battery Type | 2 x AAA batteries |
| HCT Range | 30-60% |
| System | FAD-GDH System |
| Operating Temperature | 10°C - 35°C (50°F - 95°F) |

Image: Technical specifications of the Safe-Accu2 meter, including measurement range and sample size.
Warranty and Support
For warranty information, product registration, or technical support, please refer to the warranty card included in your product packaging or visit the official Sinocare website. Keep your purchase receipt as proof of purchase.
Manufacturer: Changsha Sinocare Inc.
Contact: Please refer to the official Sinocare website or contact information provided in your product packaging for customer service.