ZTYXUX ZS3-VA

ZTYXUX ZS3-VA Overvoltage and Undervoltage Protection Circuit Breaker User Manual

1. Introduction

This manual provides essential information for the safe and effective installation, operation, and maintenance of the ZTYXUX ZS3-VA Overvoltage and Undervoltage Protection Circuit Breaker. This device is designed to protect electrical equipment from damage caused by abnormal voltage fluctuations and overcurrent conditions in AC 220V systems. Please read this manual thoroughly before use and retain it for future reference.

2. Safety Information

WARNING: Electrical work should only be performed by qualified personnel. Failure to follow these safety instructions may result in electric shock, fire, or serious injury.

  • Always disconnect power to the circuit before installation, wiring, or maintenance.
  • Ensure all wiring connections are secure and comply with local electrical codes.
  • Do not operate the device if it appears damaged.
  • Do not exceed the specified voltage and current ratings of the device.
  • Keep the device away from water and excessive moisture.

3. Product Overview

The ZS3-VA is an intelligent protection device featuring a digital display for real-time voltage and current monitoring. It automatically disconnects the circuit when voltage or current exceeds user-defined safe limits and reconnects once conditions return to normal after a set delay. The device includes control buttons for parameter adjustment.

Front view of the ZTYXUX ZS3-VA Overvoltage and Undervoltage Protection Circuit Breaker

Figure 3.1: Front view of the ZS3-VA protector, showing the digital display for voltage (red) and current (green), and control buttons (M, Up, Down, Power).

4. Specifications

ParameterValue
Rated Operating VoltageAC 220V
Rated Current40A or 63A (model dependent)
Overvoltage Protection RangeAdjustable, typically 230V - 300V
Undervoltage Protection RangeAdjustable, typically 130V - 210V
Overcurrent Protection RangeAdjustable, typically 1A - 40A/63A
Recovery Delay TimeAdjustable, typically 1 - 999 seconds
Mounting35mm DIN Rail
Dimensional drawing of the ZTYXUX ZS3-VA Overvoltage and Undervoltage Protection Circuit Breaker

Figure 4.1: Dimensions of the ZS3-VA protector, showing measurements such as 86mm height, 38mm width, and 66mm depth.

5. Setup and Installation

The ZS3-VA protector is designed for installation on a standard 35mm DIN rail. Ensure the installation location is dry, well-ventilated, and free from corrosive gases.

5.1 Wiring Instructions

  1. Power Disconnection: Before starting, ensure the main power supply to the circuit is completely disconnected.
  2. Mounting: Snap the device onto a 35mm DIN rail securely.
  3. Input Wiring: Connect the incoming live (L) and neutral (N) wires to the 'IN' terminals of the protector. Ensure correct polarity.
  4. Output Wiring: Connect the outgoing live (L) and neutral (N) wires to the 'OUT' terminals of the protector, which will lead to the load.
  5. Secure Connections: Tighten all terminal screws firmly to prevent loose connections, which can cause overheating or malfunction.
  6. Power Restoration: Once all connections are verified, restore power to the circuit.
Side view of the ZTYXUX ZS3-VA protector showing input and output terminals

Figure 5.1: Side view of the ZS3-VA protector, illustrating the 'IN' (input) and 'OUT' (output) terminals for live (L) and neutral (N) connections.

6. Operating Instructions

Upon power-up, the device will display real-time voltage and current. The red display shows voltage, and the green display shows current.

6.1 Button Functions

  • M Button: Enters/exits parameter setting mode, cycles through parameters.
  • Up Arrow Button: Increases parameter value.
  • Down Arrow Button: Decreases parameter value.
  • Power Button (Red): Manually turns the output ON/OFF.

6.2 Parameter Setting

To adjust protection parameters:

  1. Press and hold the 'M' button for approximately 3 seconds to enter the setting mode. The display will show the first adjustable parameter (e.g., 'P-1' for overvoltage threshold).
  2. Use the 'Up' and 'Down' arrow buttons to adjust the value of the displayed parameter.
  3. Press the 'M' button briefly to confirm the current setting and move to the next parameter (e.g., 'P-3' for undervoltage threshold, 'P-5' for overcurrent threshold, 't' for recovery delay time).
  4. Repeat step 2 and 3 for all desired parameters.
  5. After setting all parameters, press and hold the 'M' button again for 3 seconds to save the settings and exit the setting mode. If no button is pressed for a period, the device will automatically exit setting mode and save changes.

6.3 Display Modes and Fault Indication

The device continuously displays real-time voltage and current. In case of an overvoltage, undervoltage, or overcurrent event, the device will trip, disconnect the load, and display an error code or flashing indicator. After the fault clears and the set recovery delay time expires, the device will automatically reconnect the load.

Series of ZTYXUX ZS3-VA devices showing various display states and parameter settings

Figure 6.1: Examples of ZS3-VA display states, including 'ON' (normal operation), 'OFF' (manual shutdown), and parameter setting modes like 'P-1' (overvoltage), 'P-3' (undervoltage), and 'P-5' (overcurrent).

7. Maintenance

The ZS3-VA protector requires minimal maintenance. Follow these guidelines:

  • Cleaning: Periodically clean the device exterior with a soft, dry cloth. Do not use abrasive cleaners or solvents.
  • Connection Check: Annually inspect all wiring connections to ensure they remain tight and free from corrosion.
  • Environmental Conditions: Ensure the operating environment remains within specified temperature and humidity ranges.

8. Troubleshooting

ProblemPossible CauseSolution
Device does not power onNo power supply; incorrect wiringCheck main power supply; verify input wiring (L and N)
Frequent trippingProtection parameters set too low/high; unstable power supply; overloaded circuitAdjust overvoltage/undervoltage/overcurrent thresholds; consult an electrician to check power quality or load
Device trips but does not resetFault condition persists; recovery delay time too longVerify the fault condition has cleared; check recovery delay time setting
Display is blank or erraticInternal fault; power issueDisconnect power, wait a few minutes, then reconnect. If issue persists, contact support.

9. Warranty and Support

For warranty information and technical support, please refer to the documentation provided with your purchase or contact your retailer/manufacturer directly. Ensure you have your product model number (ZS3-VA) and purchase details available when seeking support.

Related Documents - ZS3-VA

Preview VaneAims All-in-One Smart Protector with Auto-Reconnect: User Manual
Comprehensive user manual for the VaneAims All-in-One Smart Protector with Auto-Reconnect, detailing setup, technical specifications, and operational instructions for voltage and current protection.
Preview Energenie EG-AVR-1001 Automatic AC Voltage Regulator and Stabilizer User Manual
User manual for the Energenie EG-AVR-1001 Automatic AC Voltage Regulator and Stabilizer. Features include AVR, pure sinusoidal AC output, LED status, and protection. Specifications, warranty, and safety information are provided.
Preview Vividia Ablescope USB Borescope Cameras and Bundles User Guide
This guide provides information on Vividia Ablescope USB Borescope Cameras and Bundles, including features, benefits, setup instructions, software compatibility, bundle options, and safety precautions.
Preview SVC Automatic Voltage Stabilizers FL Series (600-5000 VA) User Manual
User manual for SVC Automatic Voltage Stabilizers, FL Series (600-5000 VA). Covers installation, connection, operation, technical specifications, and safety instructions for models FL-600, FL-1000, FL-1500, FL-2000, FL-3000, and FL-5000.
Preview Instrukcja Obsługi Pojemników Szklanych VacSy® Zepter
Kompletna instrukcja obsługi, wskazówki dotyczące użytkowania, konserwacji, bezpieczeństwa i gwarancji dla szklanych pojemników na żywność VacSy® firmy Zepter, wraz z danymi technicznymi i informacjami o produktach.
Preview Intermatic T105 24-Hour Dial Time Switch: Installation, Wiring, and Operation Guide
Comprehensive guide for the Intermatic T105 24-hour mechanical dial time switch. Covers model specifications, safety warnings, wiring instructions for various configurations (SPNO, SPNC, SPDT), programming procedures, and manual operation. Includes a detailed table of electrical ratings and wire gauge recommendations.