Introduction
This manual provides comprehensive instructions for the installation, operation, and maintenance of your ASD 2x2 LED Flat Panel Light with Motion Sensor. Please read this manual thoroughly before installation and retain it for future reference. This product is designed for indoor use only in commercial or industrial settings such as offices, schools, hospitals, retail spaces, and residential areas.
Safety Information
- WARNING: Risk of electric shock. Disconnect power at the fuse or circuit breaker before installation or servicing.
- Installation should be performed by a qualified electrician.
- Ensure the supply voltage is compatible with the luminaire (120-277V).
- Do not handle live wires.
- This product is suitable for damp locations.
- Do not modify the fixture.
Product Features
- Modern Design: LED back-lit flat panel with anti-glare PC lens and durable commercial-grade aluminum housing.
- Microwave Motion Sensor: Built-in sensor automatically turns off the fixture when no motion is detected. Settings are adjustable via remote control (sold separately, ASIN B0D2KRKZHN).
- Color and Power Selectable: Choose between 3500K Neutral White, 4000K Cool White, or 5000K Daylight color temperatures and adjust power (20W/25W/30W) with a simple switch.
- Dimmable Driver: 0-10V dimmable driver with circuit overload, short circuit, and low-voltage protection.
- Long Lifespan: Calculated lifespan up to 180,000 hours.
- Certifications: UL and DLC Premium certified.
Setup and Installation
The ASD 2x2 LED Flat Panel Light offers multiple mounting options: recessed, suspended, and surface mount. This section details the recessed installation process. For suspended or surface mount installations, additional hardware (sold separately) is required.
Recessed Installation Steps:
- Prepare the Panel: Lift all mounting clips along the edges of the panel. Turn the mounting clip head outwards.
- Electrical Connection: Connect the wires into the junction box of the panel. Match the neutral (N), live (L), and ground (G) wires using appropriate wire nuts. Ensure power is disconnected before making any electrical connections.
- Secure the Panel: Adjust the panel into place within the ceiling grid. Ensure the clips are securely fastened to the ceiling's T-BAR/T-GRID.

Image: Step 1 shows how to adjust the mounting clips on the LED panel.

Image: Step 2 illustrates connecting the electrical wires to the panel's junction box.

Image: Step 3 shows the final placement and securing of the LED panel in the ceiling grid.
Other Mounting Options:
The panel supports surface mount (with ASD-FDW-ELP24 frame) and suspended mount (with ASD-CHS4 kit). These accessories are not included and must be purchased separately.

Image: This diagram illustrates the three available mounting methods: recessed, surface, and suspended.
Operating Instructions
Color Temperature and Wattage Selection:
The LED panel features selectable color temperature (CCT) and wattage settings. These can be adjusted using switches located on the fixture before installation or by using the remote control (sold separately).
- Color Temperatures: 3500K (Neutral White), 4000K (Cool White), 5000K (Daylight).
- Wattage Options: 20W, 25W, 30W.

Image: This image displays the switches for selecting desired color temperature and wattage.
Microwave Motion Sensor Operation:
The integrated microwave motion sensor detects movement and controls the light output. The sensor settings can be customized using the ASD-06RC remote control (ASIN B0D2KRKZHN), which is sold separately.

Image: This diagram shows the motion sensor's detection range and configurable parameters like hold time, stand-by period, and stand-by dimming.
Remote Control Functions (ASD-06RC, sold separately):
| Button | Function | Remarks |
|---|---|---|
| ON/OFF | Turn the sensor ON/OFF. | |
| Auto | Enter "sensor mode" and perform previous settings. | |
| Reset | Enter "sensor mode" and perform the default settings. | |
| Scenes | Shows current settings saved in remote. | |
| Start | Press this to begin scene setup. | |
| Memory | Saves the scene settings. | |
| Apply | Applies current scene settings to the fixture. | |
| Mounting Height | Adjust detection area/sensitivity levels according to real installation situations, higher or lower. | |
| Send | Memorizes and sends out the previous setting of individual parameters. | |
| Detection Range | Also known as "Sensitivity". 100% means the highest sensitivity and longest distance. Use this button and the +/- buttons to adjust. | |
| Daylight Sensor | The preset lux level at which motion will be detected. Use this button and the +/- buttons to adjust. | |
| Stand-by Dimming | After hold time, the light will dim from 100% to optional stand-by dimming levels. Use this button and the +/- buttons to adjust. | |
| Hold Time | The period that light will stay illuminated 100% after no motion is detected. Use this button and the +/- buttons to adjust. | |
| Stand-by Period | The period after hold time, during which the light keeps stand-by dimming level. Use this button and the +/- buttons to adjust. | |
| +/- | The main functional buttons to adjust the factors to desired level. | |
| Down | Press "-" button to dim light directly to non-detection mode. | |
| CCT Selectable | Not applicable to this product. | |
| Power | Adjust brightness in ON/OFF mode & sensor mode, minimum 10%, max 100%, each time this button is pressed it is changed by 3%. | |
| Reserved Button | Not applicable to this product. | |
| Daylight Harvesting | Daylight harvesting function enabled or disabled. | |
| Test Button | Press this button to test the sensor, it will temporarily change the hold time to 2s. This setting cannot be saved. |

Image: The ASD-06RC remote control, used for adjusting the motion sensor settings.
Maintenance
The ASD 2x2 LED Flat Panel Light requires minimal maintenance. Follow these guidelines to ensure optimal performance and longevity:
- Cleaning: Disconnect power before cleaning. Use a soft, dry, or slightly damp cloth to wipe the surface of the panel. Do not use abrasive cleaners, solvents, or harsh chemicals, as these can damage the finish or optical components.
- Inspection: Periodically inspect the fixture for any signs of damage, loose connections, or wear. If any issues are found, disconnect power and contact a qualified electrician for repair.
- Bulb Replacement: The LED light source is integrated and not user-replaceable. The fixture has a long lifespan, reducing the need for frequent replacements.
Troubleshooting
If you encounter issues with your LED Flat Panel Light, refer to the following common troubleshooting steps:
| Problem | Possible Cause | Solution |
|---|---|---|
| Light does not turn on. | No power supply; loose wiring; faulty fixture. | Check circuit breaker/fuse. Ensure all wiring connections are secure. If problem persists, contact support. |
| Light flickers or dims unexpectedly. | Incompatible dimmer switch; unstable power supply; loose wiring. | Ensure a 0-10V dimming system is used. Verify stable power. Check wiring connections. |
| Motion sensor not detecting movement or activating incorrectly. | Incorrect sensor settings; obstruction; sensor malfunction. | Adjust sensor settings using the remote control (hold time, detection range). Ensure no obstructions block the sensor. Reset sensor to default settings. |
| Color temperature or wattage not changing. | Switches not set correctly; remote control issue. | Verify physical switches on the fixture are set to desired CCT/wattage. If using remote, ensure it's paired and functioning. |
Specifications
| Feature | Detail |
|---|---|
| Model Number | A-BLP-22A30-MS |
| Dimensions (L x W x H) | 23.74" x 23.74" x 1.37" (603mm x 603mm x 35mm) |
| Wattage | Selectable: 20W / 25W / 30W |
| Brightness | Up to 3633 Lumens (at 30W) |
| Color Temperature (CCT) | Selectable: 3500K (Neutral White) / 4000K (Cool White) / 5000K (Daylight) |
| Voltage | 120-277V |
| Dimmable | Yes, 0-10V Dimming |
| Motion Sensor | Built-in Microwave Motion Sensor |
| Control Method | Remote (ASD-06RC, sold separately) |
| Material | Aluminum, Iron, Polycarbonate |
| CRI | >80 |
| Lifespan | 180,000 hours (calculated) |
| Certifications | UL, DLC Premium |
| Installation Type | Recessed, Surface Mount (kit sold separately), Suspended (kit sold separately) |
| Indoor/Outdoor Usage | Indoor use only |
Warranty
ASD provides a 5-year limited warranty for this product. This warranty covers defects in materials and workmanship under normal use. Please retain your proof of purchase for warranty claims. For detailed warranty terms and conditions, please refer to the official ASD website or contact customer support.
Support
For technical assistance, troubleshooting not covered in this manual, or warranty inquiries, please contact ASD customer support.
- Online Resources: Visit the official ASD website for additional product information, FAQs, and support documents.
- Contact Information: Refer to the product packaging or the ASD website for the most current customer service contact details.
Additional Resources
For a quick and hassle-free installation, you can also refer to the step-by-step manual available on our website or through the product's Amazon listing.
Official User Manual (PDF): Download PDF