1. Introduction

This manual provides essential information for the proper installation, operation, and maintenance of the JMT HLK-LD102 10g Hand Sweep Sensor Near Field Wave Trigger Radar Module. Please read this manual thoroughly before using the product to ensure optimal performance and safety.

2. Safety Information

Observe the following safety precautions to prevent damage to the module or injury to personnel:

  • Ensure the power supply meets the specified voltage and current requirements. An unstable power supply can lead to false alarms, non-induction, or cyclic self-starts.
  • Protect the microwave antenna from metal objects (e.g., solder wire) on its surface, as this can affect sensing distance and accuracy.
  • Handle the module gently to avoid intense vibration or deformation. Keep it flat during operation.
  • Maintain an independent operating space, ensuring a free space interval of more than 2mm around the module.
  • Avoid exposing the module to extreme temperatures outside the specified operating range (-20℃ to +60℃).

3. Product Overview

The JMT HLK-LD102 is a compact, high-sensitivity inductive microwave radar module designed for near-field wave triggering and hand sweep sensing applications. It offers stable performance with IO high/low level and serial communication capabilities.

JMT HLK-LD102 Inductive Microwave Radar Module

Figure 3.1: JMT HLK-LD102 Inductive Microwave Radar Module. Features include compact size, high sensitivity, anti-interference measures, and adjustable distance.

Close-up of JMT HLK-LD102 module pins

Figure 3.2: Close-up view of the HLK-LD102 module pins, labeled V (Voltage), G (Ground), O (Output), RB1, RB0, and RA2.

JMT HLK-LD102 Radar Module with Pin Test Kit

Figure 3.3: The JMT HLK-LD102 Radar Module shown with a pin test kit, illustrating the module's physical form factor and connection points.

4. Setup

Follow these guidelines for proper setup of the HLK-LD102 module:

  1. Power Supply: Connect the module to a stable power supply within the operating voltage range of 3.3V to 122V. Ensure the power supply's output voltage, current, and ripple factor meet standard requirements to prevent operational issues.
  2. Placement: Position the module in an area where the microwave antenna is unobstructed. Avoid placing metal objects directly on or very close to the antenna surface.
  3. Environmental Considerations: Be aware that reflecting microwaves from surrounding walls or obstacles can affect sensing distance and angle. Conversely, an empty surrounding environment may attenuate sensing capabilities.
  4. Isolation: Maintain a clear space of at least 2mm around the module to ensure proper operation and prevent interference.
  5. Initial Stabilization: After powering on, the module requires approximately 15 seconds for initialization and noise analysis. During this period, the module will not perform normal induction work.

5. Operating Instructions

The HLK-LD102 module is designed for hand sweep and proximity sensing. Key operational parameters include:

  • Sensing Range: The module supports an adjustable hand sweep sensing range of 0.1-0.2 meters and a proximity sensing range of 1-2 meters.
  • Sensing Angle: The typical sensing angle is 110° ±10° when wall-mounted or flush-mounted.
  • Delay Time: The default delay time, which is the duration the output state is maintained after triggering, is 5 seconds. This parameter can be adjusted as needed.
  • Sensing Distance Adjustment: The sensing distance can be adjusted to suit specific application requirements.
  • Fast Test Mode: For testing purposes, if the module is switched on and off 3 times consecutively, it will enter a fast test mode on the 4th power-on. In this mode, the delay is 5 seconds, and the distance defaults to the normal value. After testing, powering off and then on again will return the module to normal operating mode.

6. Maintenance

The JMT HLK-LD102 module is designed for low maintenance. To ensure longevity and reliable performance:

  • Keep the module clean and free from dust and debris. Use a soft, dry cloth for cleaning.
  • Avoid physical impact or excessive force on the module.
  • Regularly inspect connections for secure fit.
  • Ensure the operating environment remains within the specified temperature and humidity ranges.

7. Troubleshooting

If you encounter issues with the HLK-LD102 module, consider the following:

  • False Alarms or No Induction: This can often be caused by an unstable or inadequate power supply. Verify that the power supply meets the specified voltage, current, and ripple factor standards. Strong electromagnetic radiation in the environment can also cause false alarms.
  • Inconsistent Sensing: Test results may vary with different test environments or moving targets. The presence of a metal casing can shield electromagnetic waves and affect perceived distance.
  • Reduced Sensing Distance/Angle: Reflecting microwaves from surrounding surfaces can enhance sensing, while empty surroundings can attenuate it. Ensure the antenna is clear of obstructions, especially metal objects.
  • Cyclic Self-Start: An unstable power supply is a common cause for this behavior.
  • Weak Sensing Area: There may be inherent errors and uncertainties in weak sensing areas.

If problems persist after checking these points, consult the relevant technical personnel for assistance.

8. Specifications

ParameterValue
BrandJMT
Model NumberF53418-F53421
Sensing Range (Adjustable/Swipe)0.1 - 0.2 meters
Sensing Range (Proximity)1 - 2 meters
Sensing Angle110° ±10° (wall mounted or flush mounted)
Operating Voltage3.3V (3.3 - 122V)
Operating Current11mA @ VCC=3.3-5V (typical)
Output Voltage3V (2.9 - 3.1V)
Output Current<10mA
Power-on Stabilization Time15 seconds (typical)
Delay Time5 seconds (typical, adjustable)
Blocking Time1 second (typical)
Frequency10.525GHz (typical)
Operating Temperature-20℃ to +60℃

9. Warranty

The product information indicates a 'Warranty Description: 1'. For detailed warranty terms and conditions, please refer to the specific warranty statement provided with your purchase or contact the seller directly.

10. Support

For technical assistance, troubleshooting beyond the scope of this manual, or inquiries regarding product functionality, please contact your vendor or the manufacturer, JMT. Ensure you have your product model number (HLK-LD102) and any relevant purchase information available when seeking support.

© 2023 JMT. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.