1. Introduction
This manual provides essential information for the safe and efficient installation, operation, and maintenance of your Goodman GR9S920403AN 92% AFUE Single Stage Gas Furnace. Please read all instructions carefully before proceeding with installation or operation. Retain this manual for future reference.
The Goodman GR9S920403AN is a high-efficiency, single-stage gas furnace designed for residential heating applications. It features a 9-speed ECM blower motor and is suitable for upflow or horizontal installations.

Image 1.1: Goodman GR9S920403AN Gas Furnace, front view.
2. Safety Information
WARNING: Improper installation, adjustment, alteration, service, or maintenance can cause property damage, personal injury, or death. Read these instructions thoroughly before installing or servicing this equipment.
2.1 General Safety Precautions
- Installation and service must be performed by a qualified installer or service agency.
- Always turn off electrical power and gas supply to the furnace before performing any maintenance or service.
- Ensure proper ventilation in the installation area.
- Keep the area around the furnace clear of combustible materials, gasoline, and other flammable vapors and liquids.
2.2 Carbon Monoxide (CO) Warning
Carbon monoxide is a colorless, odorless, and poisonous gas. Improper installation or maintenance can lead to CO leakage, which can cause severe injury or death. Install carbon monoxide detectors in your home as a safety measure.
2.3 Gas Leak Safety
If you smell gas:
- Do not try to light any appliance.
- Do not touch any electrical switch; do not use any phone in your building.
- Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.
- If you cannot reach your gas supplier, call the fire department.
2.4 Electrical Safety
Ensure the furnace is properly grounded. All wiring must conform to local codes and the National Electrical Code (NEC). Use only the specified voltage and frequency (115V, 1-Phase, 60Hz).
3. Product Features
The Goodman GR9S920403AN furnace incorporates several features designed for reliable and efficient heating:
- High Efficiency: Operates at 92% AFUE (Annual Fuel Utilization Efficiency), requiring plastic/PVC flue venting.
- Single-Stage Heating: Provides consistent heat output.
- 9-Speed ECM Blower: Electronically Commutated Motor (ECM) offers nine airflow options for quiet and efficient operation, using less electricity than older PSC motors.
- Durable Construction: Features a heavy-duty aluminized-steel primary heat exchanger.
- Reliable Ignition: Equipped with a durable silicon nitride igniter.
- Advanced Control: Self-diagnostic control board with constant memory fault code history for easier troubleshooting.
- R32 Refrigerant Compliant: Designed to be compatible with R32 refrigerant systems.

Image 3.1: Illustration of 92% AFUE efficiency, requiring PVC/Plastic Venting.

Image 3.2: Diagram illustrating a single-stage burner, which is either fully on or off.

Image 3.3: Visual representation of the benefits of a 9-speed ECM blower for quiet and efficient airflow.

Image 3.4: R32 refrigerant compliance logo.
4. Setup and Installation
IMPORTANT: Installation of this furnace must be performed by a qualified HVAC technician in accordance with all local and national codes and regulations.
4.1 Pre-Installation Checks
- Verify that the furnace model matches the required specifications for your home.
- Ensure adequate space for installation, maintenance, and airflow.
- Confirm that the electrical supply (115V, 1-Phase, 60Hz) and gas supply (Natural Gas) are available and correctly sized.
- Prepare the venting system using approved plastic/PVC materials.
4.2 Installation Orientation
This furnace supports both upflow (vertical) and horizontal installations, offering flexibility for various home layouts such as attics or basements.

Image 4.1: Diagram illustrating upflow (vertical) furnace operation, where air is drawn from the bottom/side and released from the top.

Image 4.2: Diagram illustrating horizontal furnace operation, suitable for attic installations, ensuring even heating.

Image 4.3: Comprehensive diagrams showing airflow patterns for both upflow and horizontal orientations.
4.3 Gas Supply Connection
The furnace is factory-configured for natural gas. If converting to propane (LP), an optional LP conversion kit (LPM-33) is required. This conversion must be performed by a qualified technician.

Image 4.4: Components of an LP conversion kit, used to adapt the furnace for propane fuel.
5. Operating Instructions
Once installed and inspected by a qualified technician, your Goodman furnace is ready for operation.
5.1 Starting the Furnace
- Ensure the gas supply valve to the furnace is open.
- Turn on the electrical power to the furnace.
- Set your thermostat to the 'Heat' mode and adjust the temperature setting above the current room temperature.
- The furnace will initiate its start-up sequence, which typically includes a pre-purge cycle, igniter activation, and main burner ignition.
- Once the heat exchanger is warm, the blower will activate to distribute heated air.
5.2 Thermostat Settings
Refer to your thermostat's user manual for specific programming and operation. Generally, set the thermostat to your desired temperature. The furnace will cycle on and off as needed to maintain this temperature.
5.3 Normal Operation
During normal operation, you may hear the sound of the blower motor and the ignition of the gas burners. The 9-speed ECM blower is designed for quiet operation. Any unusual noises, smells, or persistent cycling should be investigated by a qualified technician.

Image 5.1: A comfortable living space, illustrating the intended outcome of proper furnace operation.
6. Maintenance
Regular maintenance is crucial for the longevity, efficiency, and safe operation of your furnace. Always disconnect electrical power and turn off the gas supply before performing any maintenance.
6.1 Air Filter Replacement
Inspect the air filter monthly and replace it every 1-3 months, or more frequently if you have pets or allergies. A dirty filter restricts airflow, reduces efficiency, and can damage the furnace.
6.2 Annual Professional Inspection
It is highly recommended to have your furnace inspected and serviced annually by a qualified HVAC technician. This inspection typically includes:
- Checking and cleaning the heat exchanger.
- Inspecting the burner and ignition system.
- Verifying gas pressure and connections.
- Checking electrical connections and components.
- Inspecting the blower motor and fan.
- Checking the flue and venting system for obstructions or leaks.

Image 6.1: Internal view of the furnace, showing various components that require professional inspection and maintenance.
7. Troubleshooting
Before calling for service, review the following common issues. Always ensure power and gas supply are on and the thermostat is set correctly.
7.1 No Heat
- Check Thermostat: Ensure it's set to 'Heat' and the temperature is above room temperature.
- Check Power: Verify the circuit breaker for the furnace is not tripped.
- Check Gas Supply: Ensure the gas valve to the furnace is open.
- Dirty Air Filter: A severely clogged filter can cause the furnace to overheat and shut off. Replace if dirty.
7.2 Weak Airflow
- Dirty Air Filter: The most common cause. Replace the filter.
- Blocked Vents: Ensure all supply and return air vents are open and unobstructed.
7.3 Unusual Noises
- Squealing: May indicate a problem with the blower motor or belt (if applicable).
- Rattling: Could be loose panels or ductwork.
- Banging: Often related to expanding and contracting ductwork.
7.4 Error Codes
The self-diagnostic control board will display error codes to indicate specific issues. Refer to the service manual (provided to your installer) for a complete list of codes and their meanings. Note the code and contact a qualified technician.
If troubleshooting steps do not resolve the issue, or if you suspect a gas leak or electrical problem, immediately contact a qualified HVAC technician.
8. Specifications
Key technical specifications for the Goodman GR9S920403AN Gas Furnace:
| Feature | Specification |
|---|---|
| Model Number | GR9S920403AN |
| Heating Capacity | 40,000 BTU/h |
| AFUE Efficiency | 92% |
| Stage Type | Single Stage |
| Blower Type | 9-Speed ECM |
| Maximum CFM | 1200 (3 Ton) |
| Electrical Supply | 115V, 1-Phase, 60Hz |
| Fuel Type | Natural Gas (LP convertible with kit) |
| Venting | Plastic/PVC Flue |
| Ignitor Type | Durable Hot Surface Igniter |
| Dimensions (H x W x D) | 34.5" x 14" x 28.7" |
| Ship Weight | 108 lbs (48.98 kg) |
| Orientation | Upflow/Horizontal |
| AHRI Number | 215224963 |

Image 8.1: Detailed dimensions of the Goodman GR9S920403AN furnace.

Image 8.2: Summary of key specifications for the furnace.

Image 8.3: Example of an Energy Guide label and AHRI Certificate of Product Ratings.
9. Warranty Information
Goodman offers comprehensive warranty coverage for this furnace, subject to specific conditions:
- Lifetime Heat Exchanger Warranty
- 10-Year Unit Replacement Warranty
- 10-Year Parts Warranty
To receive full coverage, timely online registration is required at no additional charge. Without online registration, the warranty defaults to 20-years for the heat exchanger and 5-years for parts.
Installation must comply with all local and state codes to maintain warranty coverage.
9.1 Low NOx Regulations
NOTE: This furnace DOES NOT comply with California and Colorado Low NOx and Ultra-Low NOx regulations. Installation in these states may be restricted or prohibited.

Image 9.1: Graphic representing the warranty coverage for the furnace.

Image 9.2: Map indicating states with specific NOx emission regulations.
10. Customer Support
For technical assistance, service, or warranty claims, please contact a qualified HVAC technician or the dealer from whom you purchased the unit. They are equipped to provide professional support and ensure your furnace operates safely and efficiently.
Manufacturer: Goodman
Brand: 1HVAC

Image 10.1: Goodman brand representation, symbolizing home comfort and reliability.