1. Introduction

This manual provides essential information for the safe and efficient installation, operation, and maintenance of your Goodman GR9S920403AN 92% AFUE Single Stage Gas Furnace. Please read all instructions carefully before proceeding with installation or operation. Retain this manual for future reference.

The Goodman GR9S920403AN is a high-efficiency, single-stage gas furnace designed for residential heating applications. It features a 9-speed ECM blower motor and is suitable for upflow or horizontal installations.

Goodman GR9S920403AN Gas Furnace

Image 1.1: Goodman GR9S920403AN Gas Furnace, front view.

2. Safety Information

WARNING: Improper installation, adjustment, alteration, service, or maintenance can cause property damage, personal injury, or death. Read these instructions thoroughly before installing or servicing this equipment.

2.1 General Safety Precautions

  • Installation and service must be performed by a qualified installer or service agency.
  • Always turn off electrical power and gas supply to the furnace before performing any maintenance or service.
  • Ensure proper ventilation in the installation area.
  • Keep the area around the furnace clear of combustible materials, gasoline, and other flammable vapors and liquids.

2.2 Carbon Monoxide (CO) Warning

Carbon monoxide is a colorless, odorless, and poisonous gas. Improper installation or maintenance can lead to CO leakage, which can cause severe injury or death. Install carbon monoxide detectors in your home as a safety measure.

2.3 Gas Leak Safety

If you smell gas:

  1. Do not try to light any appliance.
  2. Do not touch any electrical switch; do not use any phone in your building.
  3. Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.
  4. If you cannot reach your gas supplier, call the fire department.

2.4 Electrical Safety

Ensure the furnace is properly grounded. All wiring must conform to local codes and the National Electrical Code (NEC). Use only the specified voltage and frequency (115V, 1-Phase, 60Hz).

3. Product Features

The Goodman GR9S920403AN furnace incorporates several features designed for reliable and efficient heating:

  • High Efficiency: Operates at 92% AFUE (Annual Fuel Utilization Efficiency), requiring plastic/PVC flue venting.
  • Single-Stage Heating: Provides consistent heat output.
  • 9-Speed ECM Blower: Electronically Commutated Motor (ECM) offers nine airflow options for quiet and efficient operation, using less electricity than older PSC motors.
  • Durable Construction: Features a heavy-duty aluminized-steel primary heat exchanger.
  • Reliable Ignition: Equipped with a durable silicon nitride igniter.
  • Advanced Control: Self-diagnostic control board with constant memory fault code history for easier troubleshooting.
  • R32 Refrigerant Compliant: Designed to be compatible with R32 refrigerant systems.
92% AFUE High-Efficiency Furnace

Image 3.1: Illustration of 92% AFUE efficiency, requiring PVC/Plastic Venting.

Single Stage Burner Components

Image 3.2: Diagram illustrating a single-stage burner, which is either fully on or off.

9-Speed ECM Blower for Quiet Operation

Image 3.3: Visual representation of the benefits of a 9-speed ECM blower for quiet and efficient airflow.

R32 Refrigerant Logo

Image 3.4: R32 refrigerant compliance logo.

4. Setup and Installation

IMPORTANT: Installation of this furnace must be performed by a qualified HVAC technician in accordance with all local and national codes and regulations.

4.1 Pre-Installation Checks

  • Verify that the furnace model matches the required specifications for your home.
  • Ensure adequate space for installation, maintenance, and airflow.
  • Confirm that the electrical supply (115V, 1-Phase, 60Hz) and gas supply (Natural Gas) are available and correctly sized.
  • Prepare the venting system using approved plastic/PVC materials.

4.2 Installation Orientation

This furnace supports both upflow (vertical) and horizontal installations, offering flexibility for various home layouts such as attics or basements.

Upflow (Vertical) Furnace Installation Diagram

Image 4.1: Diagram illustrating upflow (vertical) furnace operation, where air is drawn from the bottom/side and released from the top.

Horizontal (Right/Left) Furnace Installation Diagram

Image 4.2: Diagram illustrating horizontal furnace operation, suitable for attic installations, ensuring even heating.

Upflow and Downflow Horizontal Airflow Diagrams

Image 4.3: Comprehensive diagrams showing airflow patterns for both upflow and horizontal orientations.

4.3 Gas Supply Connection

The furnace is factory-configured for natural gas. If converting to propane (LP), an optional LP conversion kit (LPM-33) is required. This conversion must be performed by a qualified technician.

LP Conversion Kit Components

Image 4.4: Components of an LP conversion kit, used to adapt the furnace for propane fuel.

5. Operating Instructions

Once installed and inspected by a qualified technician, your Goodman furnace is ready for operation.

5.1 Starting the Furnace

  1. Ensure the gas supply valve to the furnace is open.
  2. Turn on the electrical power to the furnace.
  3. Set your thermostat to the 'Heat' mode and adjust the temperature setting above the current room temperature.
  4. The furnace will initiate its start-up sequence, which typically includes a pre-purge cycle, igniter activation, and main burner ignition.
  5. Once the heat exchanger is warm, the blower will activate to distribute heated air.

5.2 Thermostat Settings

Refer to your thermostat's user manual for specific programming and operation. Generally, set the thermostat to your desired temperature. The furnace will cycle on and off as needed to maintain this temperature.

5.3 Normal Operation

During normal operation, you may hear the sound of the blower motor and the ignition of the gas burners. The 9-speed ECM blower is designed for quiet operation. Any unusual noises, smells, or persistent cycling should be investigated by a qualified technician.

Comfortable living room with Goodman furnace providing heat

Image 5.1: A comfortable living space, illustrating the intended outcome of proper furnace operation.

6. Maintenance

Regular maintenance is crucial for the longevity, efficiency, and safe operation of your furnace. Always disconnect electrical power and turn off the gas supply before performing any maintenance.

6.1 Air Filter Replacement

Inspect the air filter monthly and replace it every 1-3 months, or more frequently if you have pets or allergies. A dirty filter restricts airflow, reduces efficiency, and can damage the furnace.

6.2 Annual Professional Inspection

It is highly recommended to have your furnace inspected and serviced annually by a qualified HVAC technician. This inspection typically includes:

  • Checking and cleaning the heat exchanger.
  • Inspecting the burner and ignition system.
  • Verifying gas pressure and connections.
  • Checking electrical connections and components.
  • Inspecting the blower motor and fan.
  • Checking the flue and venting system for obstructions or leaks.
Internal view of Goodman gas furnace components

Image 6.1: Internal view of the furnace, showing various components that require professional inspection and maintenance.

7. Troubleshooting

Before calling for service, review the following common issues. Always ensure power and gas supply are on and the thermostat is set correctly.

7.1 No Heat

  • Check Thermostat: Ensure it's set to 'Heat' and the temperature is above room temperature.
  • Check Power: Verify the circuit breaker for the furnace is not tripped.
  • Check Gas Supply: Ensure the gas valve to the furnace is open.
  • Dirty Air Filter: A severely clogged filter can cause the furnace to overheat and shut off. Replace if dirty.

7.2 Weak Airflow

  • Dirty Air Filter: The most common cause. Replace the filter.
  • Blocked Vents: Ensure all supply and return air vents are open and unobstructed.

7.3 Unusual Noises

  • Squealing: May indicate a problem with the blower motor or belt (if applicable).
  • Rattling: Could be loose panels or ductwork.
  • Banging: Often related to expanding and contracting ductwork.

7.4 Error Codes

The self-diagnostic control board will display error codes to indicate specific issues. Refer to the service manual (provided to your installer) for a complete list of codes and their meanings. Note the code and contact a qualified technician.

If troubleshooting steps do not resolve the issue, or if you suspect a gas leak or electrical problem, immediately contact a qualified HVAC technician.

8. Specifications

Key technical specifications for the Goodman GR9S920403AN Gas Furnace:

FeatureSpecification
Model NumberGR9S920403AN
Heating Capacity40,000 BTU/h
AFUE Efficiency92%
Stage TypeSingle Stage
Blower Type9-Speed ECM
Maximum CFM1200 (3 Ton)
Electrical Supply115V, 1-Phase, 60Hz
Fuel TypeNatural Gas (LP convertible with kit)
VentingPlastic/PVC Flue
Ignitor TypeDurable Hot Surface Igniter
Dimensions (H x W x D)34.5" x 14" x 28.7"
Ship Weight108 lbs (48.98 kg)
OrientationUpflow/Horizontal
AHRI Number215224963
Goodman Furnace Dimensions

Image 8.1: Detailed dimensions of the Goodman GR9S920403AN furnace.

Goodman Furnace Specifications List

Image 8.2: Summary of key specifications for the furnace.

Energy Guide and AHRI Certificate for Goodman Furnace

Image 8.3: Example of an Energy Guide label and AHRI Certificate of Product Ratings.

9. Warranty Information

Goodman offers comprehensive warranty coverage for this furnace, subject to specific conditions:

  • Lifetime Heat Exchanger Warranty
  • 10-Year Unit Replacement Warranty
  • 10-Year Parts Warranty

To receive full coverage, timely online registration is required at no additional charge. Without online registration, the warranty defaults to 20-years for the heat exchanger and 5-years for parts.

Installation must comply with all local and state codes to maintain warranty coverage.

9.1 Low NOx Regulations

NOTE: This furnace DOES NOT comply with California and Colorado Low NOx and Ultra-Low NOx regulations. Installation in these states may be restricted or prohibited.

Warranty Coverage Shield

Image 9.1: Graphic representing the warranty coverage for the furnace.

US Map highlighting California and Colorado for NOx regulations

Image 9.2: Map indicating states with specific NOx emission regulations.

10. Customer Support

For technical assistance, service, or warranty claims, please contact a qualified HVAC technician or the dealer from whom you purchased the unit. They are equipped to provide professional support and ensure your furnace operates safely and efficiently.

Manufacturer: Goodman

Brand: 1HVAC

Family walking in front of a house with Goodman logo

Image 10.1: Goodman brand representation, symbolizing home comfort and reliability.

© 2024 Goodman. All rights reserved.

This manual is for informational purposes only. Consult a qualified professional for installation and service.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.