MixBubole FLO900-TQS PRO

MixBubole FLO900-TQS PRO Macerator Pump Instruction Manual

Model: FLO900-TQS PRO | Brand: MixBubole

1. Important Safety Information

Please read and understand all safety instructions before installing, operating, or performing maintenance on this product. Failure to follow these instructions may result in electric shock, fire, serious injury, or property damage.

  • Electrical Safety: Ensure the power supply matches the pump's requirements (110V-120V/60Hz). Always disconnect power before any service or maintenance.
  • Water Safety: This pump is designed for clear wastewater without solid contents. Do not use for flammable liquids, corrosive chemicals, or large solid objects.
  • Installation: Installation must comply with all local plumbing and electrical codes. Ensure proper ventilation and access for maintenance.
  • Children and Pets: Keep children and pets away from the pump and its operating area.
  • Temperature: The pump can handle continuous water temperatures up to 60°C (140°F) and up to 4 hours at 90°C (194°F). Do not exceed these limits.

2. Product Overview

The MixBubole FLO900-TQS PRO is a fully automatic 1200W macerator pump system designed for residential wastewater management where gravity drainage is not feasible. It effectively pumps wastewater from toilets, sinks, showers, laundry, and kitchen applications to a nearby outlet. The system features a robust motor, multiple inlets, and an automatic activation mechanism.

MixBubole FLO900-TQS PRO Macerator Pump

Front view of the MixBubole FLO900-TQS PRO Macerator Pump.

MixBubole Macerator Pump with specifications

Diagram highlighting key specifications: 1200W, Max 2800 GPH, 1.6HP, Max 39.4 ft Vertical lift, Max 394 ft Horizontal discharge.

Comparison table for MixBubole FLO900-TQS PRO

Comparison table detailing features of the FLO900-TQS PRO including 5 inlets, 2 outlets, internal vent, and 15x11x7 inch dimensions.

Macerator pump motor and macerating blades

Illustrations of the all-copper wire motor and stainless steel reamer blades for debris crushing.

Macerator pump features: inlets, hot water resistance, IPX4

Visuals demonstrating the 5 water inlets, 2 outlets, hot water resistance, and IPX4 waterproof design.

3. Package Contents

The MixBubole FLO900-TQS PRO Macerator Pump package includes the following components:

MixBubole Macerator Pump Package Contents

Diagram showing the macerator pump and all included accessories.

  • FLO900-TQS PRO Macerator Pump Unit
  • Plug Mounted On The Pump (x1)
  • Hose Clamp (32-50mm) (x5)
  • Plastic Inlet Hose (x5)
  • Toilet Connection Rubber Ring (x1)
  • Hose Clamp (40-60mm) (x2)
  • Plug (x3)
  • Check Valve With Plastic Elbow (x1)
  • Hose Clamp (110-120mm) (x2)
  • Front Lid (x1)

4. Specifications

FeatureSpecification
BrandMixBubole
Model NumberFLO900-TQS PRO
Wattage1200 watts
Voltage110-120 Volts / 60Hz
Maximum Flow Rate2800 GPH (46 Gallons Per Minute)
Maximum Vertical Lift39.4 Feet
Maximum Horizontal Discharge394 Feet
Motor Speed5000 RPM
Product Dimensions (L x W x H)15" x 7" x 11" (approx. 19"L x 9"W x 16"H including connections)
Item Weight18.81 pounds
MaterialPolypropylene (PP)
Inlets5 (Ø 40mm universal wastewater inlets)
Outlets2
Noise Level45 dB
Waterproof RatingIPX4
CertificationsGS, CE (TUV)

5. Installation and Setup

The MixBubole macerator pump allows for flexible installation in various locations, including basements, without extensive plumbing modifications. It can be installed with the pump and pipes behind a wall or directly behind the toilet.

Types of Macerator Pump Installations

Illustrations showing two common installation options: behind a wall or directly behind the toilet.

Slim fit installation behind a wall

Example of a slim fit installation, allowing the pump to be hidden behind a wall.

5.1 Connecting Appliances

The pump features five universal Ø 40mm wastewater inlets and two outlets, allowing connection to multiple fixtures:

  • Toilet: Connect the toilet outlet directly to the designated inlet on the macerator pump.
  • Sink/Washbasin: Connect the drain hose from the sink or washbasin to one of the universal inlets.
  • Shower/Bathtub: Connect the shower or bathtub drain to an available inlet. Ensure proper slope for gravity flow into the pump.
  • Laundry/Kitchen: Connect the discharge from washing machines or kitchen sinks to the remaining inlets.

Use appropriate hose clamps and sealing rings for all connections to prevent leaks. The discharge pipe should be 1" or 1-1/4" or 1-1/2" diameter. Ensure the discharge pipe has a slight downward slope (minimum 2%) after any vertical lift to prevent standing water.

Easy installation with various pipe sizes

Diagram illustrating compatible pipe sizes for easy installation: 1-1/2" (38mm), 1-1/4" (32mm), 1" (25mm), 0.9" (23mm).

High power upstroke distance diagram

Diagram showing the maximum vertical lift of 12 meters (39.4 feet) and recommended horizontal discharge with a slight slope.

6. Operation

The MixBubole FLO900-TQS PRO macerator pump operates with a fully automatic ON/OFF mechanism and a PCB delay function for efficient and quiet performance.

6.1 Automatic Activation

The pump activates automatically when the water level inside the unit reaches approximately 3 inches and shuts off when the level drops to 2 inches. This ensures efficient drainage and prevents unnecessary cycling.

Upgraded full-automatic switch mechanism

Close-up of the upgraded full-automatic switch, designed for safety and reliability.

6.2 PCB Delay Function

The upgraded model includes a time delay function. This feature prevents the macerator pump from activating too frequently, contributing to quieter operation and energy savings. The pump runs for a short period after the water level drops to ensure the housing is clear.

6.3 Manual Drainage Test

A manual button is provided on the unit to allow for drainage tests or to clear the pump manually if needed. Refer to the product diagram for the location of this button.

7. Maintenance

Regular maintenance ensures the longevity and optimal performance of your MixBubole macerator pump.

7.1 Cleaning and Debris Removal

In case of clogging, the cover on the top of the unit can be opened to access and agitate the blades, allowing for the removal of foreign objects without dismantling the entire water pump.

Macerator pump maintenance access

Illustration showing the top cover access for maintenance and debris removal.

7.2 Odor Control

The pump features a new enclosed design that traps odors inside, eliminating the need for activated carbon filters and regular replacement. This design contributes to a cleaner and more pleasant environment.

Odor control feature of the macerator pump

Comparison showing the enclosed design for odor prevention versus traditional activated carbon systems.

7.3 Check Valve

The pump includes a built-in check valve to prevent backflow of wastewater into the fixtures. Periodically inspect the check valve for proper function and ensure it is free from obstructions.

Built-in check valve

Close-up view of the built-in check valve mechanism.

8. Troubleshooting

This section provides solutions to common issues you might encounter with your macerator pump.

ProblemPossible CauseSolution
Pump not startingNo power; Clogged impeller; Faulty float switchCheck power connection and circuit breaker; Disconnect power and clear impeller; Contact customer support.
Pump running continuouslyFloat switch stuck; Leak in discharge pipe; Backflow from dischargeCheck float switch for obstructions; Inspect plumbing for leaks; Verify check valve is functioning correctly.
Reduced flow or weak pumpingPartial clog; Air lock; Worn impellerClear any partial clogs; Bleed air from the system if applicable; Contact customer support for impeller inspection.
Unusual noise or vibrationForeign object in pump; Loose mounting; Motor issueDisconnect power and inspect for foreign objects; Ensure pump is securely mounted; Contact customer support.
Leaks from connectionsLoose clamps; Damaged seals; Improper installationTighten all hose clamps; Inspect and replace damaged seals; Re-check installation instructions.

9. Warranty and Support

The MixBubole FLO900-TQS PRO Macerator Pump comes with a 1-year manufacturer's warranty, ensuring quality and reliability. This warranty covers defects in materials and workmanship under normal use.

For technical assistance, troubleshooting, or warranty claims, please contact MixBubole customer service. Our dedicated support team is available 7 days a week, 24 hours a day to assist you.

Please have your model number (FLO900-TQS PRO) and purchase date ready when contacting support to expedite service.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.