Introduction
This manual provides essential information for the safe and efficient operation and maintenance of your Goodman GR9S960603BN Gas Furnace. This high-efficiency, single-stage gas furnace is designed for upflow or horizontal left and right applications, offering 60,000 BTU input and 96% AFUE for optimal heating performance.

Figure 1: Goodman GR9S960603BN Gas Furnace with indicated dimensions (17.5 in. width, 28 in. depth, 33.38 in. height).
Setup and Installation
Proper installation is crucial for the safe and efficient operation of your gas furnace. It is highly recommended that installation be performed by a qualified HVAC professional.
Delivery Information
Upon delivery of your LTL (Less Than Truckload) shipment, follow these steps to ensure your product arrives safely and without issues:
- Verify Address: Double-check that your delivery address, including street name, number, and zip code, is accurate.
- Provide Contact: Ensure a daytime phone number is provided with your order so the trucking company can easily reach you to schedule delivery. Answer any unknown calls during this period to avoid delays.
- Adult Presence: An adult must be present during the scheduled delivery window to accept and sign for the shipment.
- Inspect Packaging: Carefully inspect all items on the pallet for any visible damage to the packaging or the items themselves before accepting.
- Refuse Damaged Shipments: If significant damage is noticed, refuse the shipment and immediately notify the driver.
- Document Condition: Take pictures of the packaging from all angles. This documentation is useful if any issues arise later.
- Check for Concealed Damage: After accepting, open the boxes and fully inspect all items inside for any hidden or concealed damage not visible from the outside. If found, take detailed pictures of the affected items and their packaging, then contact customer support immediately.
Video 1: Instructions on how to properly accept an LTL shipment, emphasizing inspection and documentation.
Installation Orientation
The Goodman GR9S960603BN furnace is designed for flexible installation in both upflow and horizontal (left or right) configurations. Consult the detailed installation guide provided with your unit for specific instructions and safety precautions.

Figure 2: Diagram illustrating the upflow and horizontal installation options for the furnace, showing air flow direction.
Operating Instructions
Your Goodman gas furnace is equipped with features designed for efficient and reliable heating.
Key Features for Operation
- SureStart® Silicon Nitride Igniter: Designed for extended igniter life, ensuring reliable ignition.
- Single-Stage Gas Valve: Provides quiet and economical heating operation.
- Quiet Two-Speed Induced Draft Blower: Contributes to quieter operation.
- Energy-Efficient, Multi-Speed ECM Blower Motor: Optimizes energy consumption and air delivery.
- Low Constant Fan Speed: Circulates air throughout the home, ensuring evenly distributed heating and cooling.
Video 2: Overview of standard features found in Goodman Furnaces, including igniter, heat exchangers, gas valve, and blower motor.
Video 3: Further details about Goodman Gas Furnaces, highlighting their efficiency and environmental considerations with R32 refrigerant.
Maintenance
Regular maintenance is essential to ensure the longevity and efficient operation of your furnace. It is recommended to have your furnace inspected and serviced annually by a qualified HVAC technician.
Air Filter Replacement
The air filter should be checked monthly and replaced or cleaned as needed, typically every 1-3 months depending on usage and environmental factors. The Goodman GR9S960603BN uses filters of size (1) 16" x 25" for both bottom and side access.
- Bottom Filter Size: 16" x 25"
- Side Filter Size: 16" x 25"
Refer to your furnace's specific filter location and replacement instructions in the full installation manual.
Troubleshooting
Your Goodman furnace is equipped with a self-diagnostic control board that provides constant memory fault code history output to an LED. This feature can assist technicians in quickly identifying and resolving issues.

Figure 3: Internal view of the Goodman Gas Furnace, highlighting the control board and other components for diagnostic purposes.
If your furnace is not operating correctly, check the following basic points before contacting a service professional:
- Ensure the thermostat is set to "Heat" and the desired temperature is above the current room temperature.
- Check that the furnace's power switch is in the "ON" position.
- Verify that the gas supply valve to the furnace is open.
- Inspect the air filter for excessive dirt and replace if necessary.
- Check your home's circuit breaker panel for any tripped breakers related to the furnace.
For persistent issues or complex problems, consult a certified HVAC technician. Refer to the fault codes displayed on the LED for diagnostic assistance.
Specifications
Detailed technical specifications for the Goodman GR9S960603BN Gas Furnace:
| Feature | Specification |
|---|---|
| Model Number | GR9S960603BN |
| Brand | Goodman |
| Heating Capacity (Input) | 60,000 BTU |
| Heating Capacity (Output) | 58,200 BTU |
| AFUE Efficiency | 96% |
| Gas Valve Type | Single Stage |
| Orientation | Upflow/Horizontal (Left & Right) |
| Burners | 3 |
| Speeds | 9 |
| Electrical | 115 VAC, 1 phase, 60Hz |
| Wattage | 17627 watts |
| Minimum Ampacity (Min. Ampacity) | 10.1 |
| Maximum Overcurrent Protection (MOP) | 15 |
| Filter Size (Bottom) | (1) 16" x 25" |
| Filter Size (Side) | (1) 16" x 25" |
| Dimensions (W x D x H) | 17.5" x 28.75" x 33.38" |
| Refrigerant Compatibility | Meets 2025 Refrigerant Guidelines (R-32) |
| Heat Exchanger Material | Heavy-duty stainless-steel / aluminized-steel tubular, Stainless-steel secondary |

Figure 4: EnergyGuide label for the Goodman GR9S960603BN, indicating a 97.0 AFUE efficiency rating.

Figure 5: Climate zone map providing guidance on approximate heating BTUs per square foot and cooling coverage by climate zone, useful for furnace sizing.
Warranty Information
The Goodman GR9S960603BN Gas Furnace comes with comprehensive warranty coverage:
- Lifetime Compressor Limited Warranty
- 10-Year Unit Replacement Limited Warranty
- Lifetime Heat Exchanger Limited Warranty
Please refer to the official warranty documentation included with your product for full terms, conditions, and registration requirements. Warranty details may vary and are subject to change.
Support
For technical assistance, service, or warranty claims, please contact the seller or a certified Goodman HVAC professional. Ensure you have your model number (GR9S960603BN) and serial number ready when contacting support.
For general inquiries or to find a local service provider, visit the official Goodman website or contact MRONextDay.com, the distributor of this product.