1. Introduction

This manual provides comprehensive instructions for the installation, operation, and maintenance of your AC Infinity AIRCOM S6 12-inch Rear-Exhaust Cooling Blower Fan System. This system is designed to efficiently cool various audio/video (AV) components, including receivers, amplifiers, DVRs, and gaming consoles, preventing overheating and extending their lifespan.

AC Infinity AIRCOM S6 Cooling Blower Fan System, front view

Figure 1: AC Infinity AIRCOM S6 unit, front view, showcasing its sleek design and control panel.

2. Safety Information

Please read all safety instructions before operating this product to prevent injury or damage. Keep this manual for future reference.

  • Ensure the power supply voltage matches the product's requirements.
  • Do not expose the unit to water or excessive moisture.
  • Avoid blocking the fan intake or exhaust vents to ensure proper airflow.
  • Do not attempt to disassemble or repair the unit yourself. Refer to qualified service personnel.
  • Keep the unit away from heat sources and direct sunlight.

3. Package Contents

Verify that all items are present in your package:

  • AC Infinity AIRCOM S6 Unit (1)
  • Power Adapter (1)
  • Instruction Manual (1)

4. Product Overview

The AIRCOM S6 is a quiet cooling blower fan system designed for rear-exhaust applications. It features intelligent programming and a low-profile design.

Diagram showing AC Infinity AIRCOM S6 placed on top of an AV receiver with an upward blue arrow indicating airflow

Figure 2: The AIRCOM S6 positioned above an AV receiver, illustrating its function as a component cooling system to prevent overheating.

Key Features:

  • Quiet Operation: Utilizes dual-ball bearing blowers with PWM-controlled motors for minimal noise output.
  • Intelligent Programming: Offers two thermal trigger modes and four speed control options for customized cooling.
  • Rear-Exhaust Design: Specifically configured to exhaust hot air from the rear of AV components.
  • Low Profile: Designed with a slim 1.5-inch height for placement in tight spaces or stacking with other components.
Close-up of the AC Infinity AIRCOM S6 control panel showing buttons for mode, power, and fan speed

Figure 3: Detailed view of the control panel, highlighting the intelligent programming features including multiple program modes, temperature trigger settings, and four fan speeds.

5. Setup

Follow these steps to set up your AIRCOM S6 cooling system:

  1. Placement: Position the AIRCOM S6 directly on top of the AV component you wish to cool. Ensure the rear exhaust vents are not obstructed. For optimal performance, place the unit where it can draw air from the component's vents and exhaust it freely.
  2. Power Connection: Connect the included power adapter to the unit's power input port. Plug the power adapter into a standard electrical outlet.
  3. Initial Power On: The unit will power on automatically or can be turned on using the power button on the control panel.
AC Infinity AIRCOM S6 unit placed on top of an AV receiver inside a wooden cabinet

Figure 4: The AIRCOM S6 integrated into an entertainment cabinet, demonstrating typical placement above an AV component.

6. Operating Instructions

The AIRCOM S6 features a control panel for adjusting settings. Refer to Figure 3 for control panel layout.

6.1. Power On/Off

Press the power button (usually the central button) to turn the unit on or off.

6.2. Fan Speed Control

The unit offers four fan speed settings, ranging from silent to powerful. Use the fan speed button (typically on the right) to cycle through the available speeds. Higher speeds provide more airflow but may produce slightly more noise.

6.3. Thermal Trigger Modes

The AIRCOM S6 includes two thermal trigger modes. These modes allow the fan to automatically adjust its speed or turn on/off based on detected temperature. Consult the detailed product manual for specific instructions on setting temperature thresholds and mode selection.

6.4. Power Outage Memory

The system retains its last settings in the event of a power outage, resuming operation with the previously selected mode and speed once power is restored.

7. Maintenance

Regular maintenance ensures optimal performance and longevity of your AIRCOM S6 unit.

  • Cleaning: Periodically clean the fan grilles and exterior surfaces with a soft, dry cloth. Do not use abrasive cleaners or solvents.
  • Dust Removal: Use a can of compressed air to gently clear dust from the fan blades and internal components through the grilles. Ensure the unit is powered off and unplugged before cleaning.
  • Inspection: Regularly check the power cord and adapter for any signs of damage.

8. Troubleshooting

If you encounter issues with your AIRCOM S6, refer to the table below for common problems and solutions.

Problem Possible Cause Solution
Unit does not power on. No power, faulty adapter, or unit malfunction. Check power outlet. Ensure power adapter is securely connected. Try a different outlet. If problem persists, contact support.
Fans are not spinning. Unit is off, fan speed set to zero, or thermal trigger not met. Ensure unit is powered on. Increase fan speed. Check thermal trigger settings if in auto mode.
Unit is making unusual noise. Obstruction in fan, excessive dust, or fan bearing issue. Power off and unplug the unit. Carefully inspect for obstructions. Clean dust from fans. If noise persists, contact support.
Insufficient cooling. Low fan speed, blocked vents, or improper placement. Increase fan speed. Ensure component and unit vents are clear. Adjust placement for better airflow.

9. Specifications

Technical details for the AC Infinity AIRCOM S6:

  • Model: AI-ACS6
  • Dimensions (L x W x H): 11.6" x 6.3" x 1.5" (29.5 cm x 16.0 cm x 3.8 cm)
  • Exhaust Direction: Rear
  • Airflow: 100 CFM (Cubic Feet per Minute)
  • Noise Level: 20 dBA (Decibels, A-weighted)
  • Power Consumption: 5.2 Watts
  • Fan Type: Dual-ball bearing blowers
  • Material: Alloy Steel
  • Compatible Devices: Receivers, Amplifiers, DVRs, Gaming Consoles, and other AV components.
Diagram showing the dimensions and key specifications of the AC Infinity AIRCOM S6

Figure 5: Visual representation of the AIRCOM S6 dimensions and core specifications.

10. Warranty and Support

AC Infinity products are designed with quality and durability in mind. For warranty information and customer support, please visit the official AC Infinity website or contact their customer service department.

  • Official Website: www.acinfinity.com
  • Contact Support: Refer to the website for contact methods, including email and phone support.

Please have your model number (AI-ACS6) and purchase date available when contacting support.

Related Documents - AI-ACS6

Preview AC Infinity AIRCOM Series Component Cooling System User Manual
User manual for the AC Infinity AIRCOM Series component cooling systems, detailing product features, requirements, setup, programming, FAQs, and warranty information. Includes model numbers and specifications for AIRCOM S and T series.
Preview AC Infinity AIRCOM Series Component Cooling System User Manual
User manual for the AC Infinity AIRCOM Series Component Cooling System. Learn about product requirements, key features, setup, programming, and troubleshooting for models like AIRCOM S6, S7, S8, S9, S10, T8, T9, and T10. Includes warranty information and contact details.
Preview AC Infinity AIRCOM Series Component Cooling System User Manual
User manual for the AC Infinity AIRCOM Series component cooling systems, detailing product requirements, features, setup, programming, other products, and warranty information.
Preview AC Infinity Axial Series Project Cooling Fans User Manual
Comprehensive user manual for AC Infinity Axial Series project cooling fans. Covers product specifications, key features, contents, fan replacement, mounting, powering, speed controller operation, other AC Infinity products, and warranty information.
Preview AC Infinity AIRCOM Series Component Cooling System User Manual | Digital Cinema
User manual for the AC Infinity AIRCOM Series component cooling systems, available at Digital Cinema. Learn how to set up, program, and utilize features for optimal performance of your audio-video equipment.
Preview AC Infinity AIRCOM Series Component Cooling System User Manual
User manual for AC Infinity's AIRCOM Series component cooling systems, covering setup, features, programming, and FAQs for models like AIRCOM S6, S7, S8, S9, S10, T8, T9, and T10. Essential guide for optimizing AV equipment cooling.