1. Introduction

This user manual provides detailed instructions for the safe and efficient installation, operation, and maintenance of the Knightsbridge M6300 Metal Clad 13A Switched Spur Unit. Please read this manual thoroughly before installation and retain it for future reference.

The M6300 is a heavy-duty metal clad switched fused spur unit designed for robust electrical installations. Key features include:

2. Safety Information

WARNING: Electrical installations should only be carried out by a qualified electrician in accordance with current wiring regulations (e.g., BS 7671 in the UK).

3. Package Contents

Verify that all components are present and undamaged upon unpacking:

Knightsbridge M6300 Metal Clad 13A Switched Spur Unit

Figure 3.1: Front view of the Knightsbridge M6300 Metal Clad 13A Switched Spur Unit. The unit features a robust silver metal casing, a white rocker switch on the right, and a fuse holder on the left, clearly marked "FUSE".

4. Installation

The M6300 unit is designed for fixed wiring installations. Follow these steps carefully:

  1. Preparation: Ensure the mains electricity supply to the circuit where the unit will be installed is completely isolated at the consumer unit/fuse board. Use a suitable voltage tester to confirm the circuit is dead.
  2. Mounting:
    • The unit comes with an integrated back box. Mark the desired mounting position on the wall.
    • Drill appropriate holes for the mounting screws.
    • Secure the back box to the wall using suitable screws and wall plugs.
  3. Wiring:
    • Carefully strip the insulation from the circuit cables (Live, Neutral, Earth) to the appropriate length for the terminals.
    • Connect the incoming Live (brown or red) cable to the "L IN" terminal.
    • Connect the incoming Neutral (blue or black) cable to the "N IN" terminal.
    • Connect the incoming Earth (green/yellow) cable to the "E" terminal.
    • Connect the outgoing Live (brown or red) cable to the "L OUT" terminal.
    • Connect the outgoing Neutral (blue or black) cable to the "N OUT" terminal.
    • Ensure all terminal screws are tightened securely to prevent loose connections.
  4. Fusing: Insert a 13A fuse into the fuse holder. Ensure the fuse is correctly seated.
  5. Final Assembly: Carefully position the front plate onto the back box, ensuring no wires are trapped. Secure the front plate with the provided screws.
  6. Testing: Once installation is complete, restore the mains electricity supply and test the unit's functionality.

5. Operation

The Knightsbridge M6300 is a simple ON-OFF switched spur unit. Its operation is straightforward:

6. Maintenance

The M6300 unit requires minimal maintenance. Follow these guidelines to ensure its longevity and safe operation:

7. Troubleshooting

If you encounter issues with your M6300 unit, refer to the following common problems and solutions:

ProblemPossible CauseSolution
No power to connected appliance.
  • Unit switch is OFF.
  • Blown fuse.
  • Loose wiring connection.
  • Circuit breaker tripped.
  • Switch unit ON.
  • Replace 13A fuse (ensure power is off first).
  • Isolate power and check wiring connections (consult electrician).
  • Reset circuit breaker at consumer unit.
Unit feels warm.
  • Overload on circuit.
  • Loose connection.
  • Reduce load or check appliance.
  • Isolate power and check wiring connections (consult electrician).
Switch is stiff or not operating smoothly.
  • Internal mechanism issue.
  • Debris.
  • Do not force. Unit may need replacement.
  • Clean around switch (ensure power is off).

If the problem persists after attempting these solutions, please contact a qualified electrician or Knightsbridge customer support.

8. Specifications

Technical specifications for the Knightsbridge M6300 Metal Clad 13A Switched Spur Unit:

Knightsbridge M6300 Data Sheet

Figure 8.1: Data sheet for Knightsbridge Metalclad 13A fused spur units, including the M6300 model. This sheet provides detailed technical specifications and dimensions for various models in the series.

SpecificationValue
Model NumberM6300
BrandKnightsbridge
Current Rating13 Amps
Operating Voltage230 Volts
Operation ModeON-OFF
Contact TypeNormally Open
Connector TypeClamp
Terminal TypeScrew
Circuit Type1-way
Actuator TypePush Button
Contact MaterialMetal
International Protection Rating (IP)IP33
Number of Positions1
Control MethodTouch
Wattage2990 Watts (2.99E+3)
Product Dimensions (L x W x H)3.21 x 1.93 x 32.09 inches
Item Weight7.4 ounces
MaterialMetal
CertificationBS 1363-4
Standard Warranty1 year (as per datasheet)

9. Warranty and Support

The Knightsbridge M6300 Metal Clad 13A Switched Spur Unit is manufactured to high standards and is certified to BS 1363-4. Based on the provided data sheet, a standard warranty of 1 year is typically offered.

For technical support, warranty claims, or further assistance, please contact Knightsbridge customer service or refer to their official website. Ensure you have your product model number (M6300) and purchase details available when contacting support.

Manufacturer: Knightsbridge

Website: www.mlaccessories.co.uk (ML Accessories is the parent company of Knightsbridge)

Related Documents - M6300

Preview Knightsbridge Electrical Accessories Installation Guide and Product Information
Comprehensive guide to installing and using Knightsbridge electrical accessories, including sockets, switches, USB chargers, dimmers, and Bluetooth speaker products. Features safety information, wiring diagrams, and warranty details.
Preview Knightsbridge Electrical Accessories: Installation Guide and Safety Information
Comprehensive installation guide and safety information for Knightsbridge electrical accessories, including sockets, switches, dimmers, and USB charging outlets. Covers wiring diagrams, safety warnings, product specifications, and warranty details.
Preview Knightsbridge Electrical Accessories Installation and Safety Guide
Comprehensive guide for installing and safely using Knightsbridge electrical accessories, including sockets with USB chargers and Bluetooth speakers. Covers wiring, safety precautions, and warranty information.
Preview Knightsbridge Electrical Accessories Installation and Safety Guide
Comprehensive guide to the safe installation and operation of Knightsbridge electrical accessories, including sockets, USB chargers, dimmers, and switches. Covers wiring, safety precautions, and product specifications.
Preview Knightsbridge 2023 Lighting & Wiring Accessories Catalogue
Explore the comprehensive 2023 catalogue from Knightsbridge, featuring a wide range of lighting and wiring accessories, including switches, sockets, USB chargers, and smart home solutions. Discover quality products for domestic and commercial applications.
Preview Knightsbridge SK006 IP54 3-Gang Pop-Up Socket: Installation & Maintenance Manual
This manual provides comprehensive installation, operation, and maintenance instructions for the Knightsbridge SK006 IP54 3-Gang Pop-Up Socket. It covers safety precautions, installation steps, usage guidelines, warnings, and warranty information.