DIYPHONE iFixes iL37 LED Ring Light
DIYPHONE iFixes iL37 Polarized 96-LED Ring Light Instruction Manual
Model: iFixes iL37 LED Ring Light
1. Introduction
The DIYPHONE iFixes iL37 Polarized 96-LED Ring Light is designed to provide cool, bright, and anti-glare illumination for various microscope applications, particularly for soldering repair and industrial camera use. It features a built-in polarizer and analyzer to reduce reflections and enhance color clarity when observing metallic or reflective surfaces.
2. Safety Information
- Ensure the power source matches the device's requirements (USB).
- Do not expose the device to water or excessive moisture. It is not water-resistant.
- Avoid direct eye exposure to the LED light for prolonged periods.
- Handle the polarizing lenses with care to prevent scratches.
- Keep out of reach of children.
3. Package Contents
Verify that all items are present in the package:
- 1 x iFixes iL37 Polarized 96-LED Ring Light (with USB interface power cord)
- Mounting Screws (typically 3)
- Polarizing Lens (pre-installed or separate)

Image: The iFixes iL37 Polarized 96-LED Ring Light, showing the main unit, USB power cord, and mounting screws.
4. Product Overview
The iFixes iL37 features 96 LED lights for bright illumination. It includes a rotatable analyzer and a removable polarizer for glare reduction. The unit is designed with a wear- and heat-resistant metal housing.

Image: Top view of the iFixes iL37 LED Ring Light, highlighting the 96 LED arrangement.

Image: Side view of the iFixes iL37 LED Ring Light, showing its dimensions (82mm diameter, 22mm height) and metal housing.

Image: The iFixes iL37 with the polarizing lens inserted, demonstrating its anti-glare capability.
5. Setup and Installation
Follow these steps to install the iFixes iL37 Polarized 96-LED Ring Light onto your microscope:
- Step 1: Prepare the Ring Light. Fully unscrew the fixing screws on the ring light to open the aperture sufficiently for mounting.
- Step 2: Mount onto Microscope. Insert the ring light onto the objective lens of your stereo microscope. Ensure it is seated properly, then tighten the screws to secure it in place.
- Step 3: Connect Power. Connect the USB power cord to a suitable power source. For optimal brightness, use a high-power charger. Connecting to a computer's USB port may result in lower brightness.

Image: A hand unscrewing the fixing screws on the iFixes iL37 ring light.

Image: A hand installing the iFixes iL37 ring light onto the objective lens of a microscope and tightening the screws.

Image: A hand connecting the USB power cord to a power adapter.
Note: The iFixes iL37 is compatible with monocular and other types of microscopes.
6. Operating Instructions
6.1 Power On/Off and Brightness Adjustment
Press the power button to turn the light on or off. The brightness can be adjusted by pressing the designated buttons or rotating the control ring (if applicable to your model). The device defaults to full brightness upon power-on.
6.2 Using the Polarizing Feature
The iFixes iL37 includes a built-in polarizer and a rotatable analyzer. This feature is crucial for reducing glare and reflections, especially when viewing metallic components or highly reflective surfaces under the microscope.
- Insert Polarizer: Ensure the polarizer lens is correctly seated in its slot.
- Rotate Analyzer: Gently rotate the 360° analyzer ring on the light. Observe the microscope's view as you rotate. You will notice a significant reduction in glare and an improvement in color clarity and contrast.
- Adjust for Optimal View: Continue rotating until reflections are minimized and the details of your specimen are most visible. The polarizer can be removed if not needed.

Image: Comparison of a circuit board under a microscope, showing reduced glare and improved clarity with the polarized light activated (right) versus without (left).

Image: A microscope setup demonstrating the effect of rotating the analysis aperture to adjust glare and improve observation angles.
Video: An official product video demonstrating the iFixes iL37 Polarized Ring Light in use, showcasing its anti-glare capabilities and ease of installation and adjustment.
7. Maintenance
- Cleaning: Use a soft, dry cloth to clean the exterior of the ring light. For the LED surface and polarizing lenses, use a lens cleaning cloth and appropriate lens cleaning solution to avoid scratches.
- Storage: Store the ring light in a clean, dry environment when not in use.
- Cable Care: Avoid bending or crimping the USB power cord excessively to prevent damage.
8. Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| Light does not turn on. | No power, loose USB connection, faulty power source. | Check USB connection. Try a different USB port or power adapter. Ensure the power button is pressed. |
| Light is dim. | Low power USB source (e.g., computer USB port), brightness setting too low. | Connect to a high-power USB charger. Adjust brightness using the control. |
| Glare or reflections still visible. | Polarizer not correctly adjusted, polarizer lens dirty. | Rotate the analyzer ring to find the optimal position. Clean the polarizing lens. |
| Ring light is loose on the microscope. | Mounting screws not tightened sufficiently. | Ensure the three mounting screws are evenly and securely tightened. |
9. Specifications
- Model: iFixes iL37 LED Ring Light
- LED Count: 96 LEDs
- Connectivity: USB
- Features: Polarized illumination, anti-glare, adjustable brightness, 360° rotatable analyzer
- Compatible Devices: Monocular and type microscopes
- Material: Wear- and heat-resistant metal housing
- Water Resistance: Not Water Resistant
10. Warranty and Support
This product comes with a standard manufacturer's warranty. For warranty claims, technical support, or any inquiries, please contact DIYPHONE customer service through the retailer where the product was purchased or visit the official DIYPHONE website.
Please retain your proof of purchase for warranty purposes.