AOPUTTRIVER AP-886A

AOPUTTRIVER AP-886A Nuclear Radiation Detector User Manual

Model: AP-886A

1. Introduction

The AOPUTTRIVER AP-886A Nuclear Radiation Detector is a sophisticated device designed for detecting Gamma, Beta, and X-rays. Equipped with an upgraded GM sensor and a clear 2.5-inch high-definition LCD display, it provides real-time irradiance readings, maximum and average readings, and current temperature and humidity levels. This manual provides detailed instructions for the proper setup, operation, and maintenance of your radiation detector.

AOPUTTRIVER AP-886A Nuclear Radiation Detector overview

Figure 1.1: Overview of the AOPUTTRIVER AP-886A Nuclear Radiation Detector and its applications.

2. Package Contents

Upon unboxing your AOPUTTRIVER AP-886A Nuclear Radiation Detector, please verify that all the following items are included:

  • 1 x AP-886A Nuclear Radiation Detector
  • 1 x USB Type-C Charging Cable
  • 1 x User Manual (this document)
Contents of the AP-886A package

Figure 2.1: The AP-886A detector, USB-C charging cable, and user manual as included in the product packaging.

3. Key Features

The AP-886A detector offers a range of features for comprehensive radiation monitoring:

  • Radiation Detection: Upgraded GM sensor for detecting Gamma, Beta, and X-rays.
  • Cumulative Dose Equivalent: Measures from 0.00uSv to 500.0mSv.
  • Energy Range: 48KeV-1.5MeV ≤ ±30% (for 137Csγ).
  • Large LCD Display: Backlit 2.5-inch high-definition display showing real-time irradiance, maximum, average readings, temperature, and humidity.
  • Intelligent Alarm System: Customizable current and cumulative dose alarm values with sound, vibration, and blinking light alerts. Cumulative dose equivalent value can be cleared.
  • Multiple Dosage Units: Choose from µSv/h, µGy/h, mR/h, cps, and cpm.
  • Trend Graph Option: Visual representation of radiation levels over time for easier monitoring.
  • Rechargeable Battery: Powered by an 1100mAh rechargeable lithium battery with USB Type-C charging.
Key features of the Geiger Counter Nuclear Radiation Detector

Figure 3.1: Visual representation of the detector's key specifications and capabilities.

Upgraded Geiger Counter features

Figure 3.2: Detailed view of the upgraded Geiger Counter's detection types, sensitivity, and energy range.

4. Setup

Before first use, ensure the device is fully charged. The AP-886A features an internal rechargeable battery.

4.1 Charging the Device

  1. Locate the USB Type-C port on the right side of the detector.
  2. Connect the provided USB Type-C charging cable to the detector.
  3. Plug the other end of the USB cable into a compatible USB power adapter (not included) or a computer's USB port.
  4. An LED light will indicate that the device is charging.
Rechargeable lithium battery and USB-C charging

Figure 4.1: The AP-886A connected to its USB Type-C charging cable, highlighting its 1100mAh rechargeable lithium battery.

Rechargeable Lithium Battery with power adapter

Figure 4.2: The detector being charged via a wall adapter, demonstrating its rechargeable capability and up to 10 hours of standby time.

4.2 Powering On/Off

To power on the device, press and hold the central "OK" button. The device will boot up and display the main monitoring interface. To power off, press and hold the same button until the display turns off.

Video 4.1: This video demonstrates the unboxing, charging, and initial power-on sequence of the AOPUTTRIVER AP-886A Nuclear Radiation Detector, along with an overview of its display and settings.

5. Operating Instructions

The AP-886A features an intuitive interface for monitoring and adjusting settings.

5.1 Main Display Overview

The 2.5-inch LCD display provides comprehensive information at a glance:

  • Top Bar: Current date, time, alarm indicators (flashing lights, vibration, audible alarm), and battery indicator.
  • Left Panel: Current radiation level (e.g., in mR/h).
  • Right Panel: Maximum and average radiation limits (e.g., in µSv/h), current alarm level, and lifetime measurement time.
  • Bottom Panel: Temperature (Fahrenheit or Celsius) and humidity readings.
Monitoring interface of the AP-886A

Figure 5.1: The main monitoring interface displaying current, maximum, and average radiation levels, along with temperature and humidity.

2.5 inch high-definition LCD display

Figure 5.2: The 2.5-inch high-definition LCD display showing a trend graph of radiation levels over time.

5.2 Navigation and Settings

Use the directional buttons around the "OK" button to navigate the menu and adjust settings.

  1. Accessing Settings: Press the "OK" button to enter the main settings menu.
  2. Set Unit: Change measurement units for radiation (µSv/h, µGy/h, mR/h, CPS, CPM).
  3. Set Alarm: Configure current and cumulative alarm thresholds. The device will alert you via sound, vibration, and blinking lights if these thresholds are exceeded.
  4. Sys Clock: Adjust the system date and time.
  5. Ala Mode: Enable or disable specific alarm modes (LED light, Shake/Vibration, Voice/Audible).
  6. Set Disp: Adjust display brightness and change the display language (e.g., to English).
Alarm settings for the radiation detector

Figure 5.3: The interface for setting current and cumulative alarm values, providing visual cues for radiation levels.

Conversion of radioactive units table

Figure 5.4: A table illustrating the conversion of various radioactive units according to International Standards (1990).

6. Maintenance

To ensure the longevity and accuracy of your AP-886A Nuclear Radiation Detector, follow these maintenance guidelines:

  • Cleaning: Use a soft, dry cloth to clean the device. Do not use abrasive cleaners or solvents, as they may damage the display or casing.
  • Storage: Store the detector in a cool, dry place away from direct sunlight and extreme temperatures.
  • Battery Care: Recharge the device regularly, especially if it will be stored for an extended period, to maintain battery health. Avoid fully depleting the battery frequently.
  • Handling: Handle the device with care to prevent drops or impacts that could damage internal components.

7. Troubleshooting

If you encounter any issues with your AP-886A Nuclear Radiation Detector, consider the following common troubleshooting steps:

  • Device Not Turning On: Ensure the battery is charged. Connect the device to the USB Type-C charger and allow it to charge for at least 30 minutes before attempting to power it on again.
  • Inaccurate Readings: Ensure the device is in an open area away from potential sources of interference. Calibrations are factory set, but if persistent issues occur, contact support.
  • Alarm Not Functioning: Check the "Ala Mode" settings in the menu to ensure LED, Shake, and Voice alarms are enabled. Verify alarm thresholds are set appropriately.
  • Display Issues: If the display is dim, adjust the brightness in the "Set Disp" menu. If the display is unresponsive, try restarting the device.

For issues not resolved by these steps, please refer to the Warranty and Support section.

8. Specifications

Detailed technical specifications for the AOPUTTRIVER AP-886A Nuclear Radiation Detector:

AttributeValue
Detection RaysGamma, Beta, X-rays
Cumulative Dose Equivalent0.00uSv-500.0mSv
Energy Range48KeV-1.5MeV ≤ ±30% (for 137Csγ)
Display2.5-inch High-Definition LCD
Dosage UnitsµSv/h, µGy/h, mR/h, cps, cpm
Battery1100mAh Rechargeable Lithium Battery
Charging PortUSB Type-C
Package Dimensions7.95 x 4.69 x 1.97 inches
Item Weight9.59 ounces
ManufacturerAOPUTTRIVER
Country of OriginChina
Dimensions of the AP-886A Nuclear Radiation Detector

Figure 8.1: Physical dimensions of the AP-886A detector.

9. Warranty and Support

AOPUTTRIVER is committed to providing high-quality products and customer satisfaction. If you encounter any problems with your AP-886A Nuclear Radiation Detector, please contact AOPUTTRIVER customer support for assistance. Refer to the product packaging or the official AOPUTTRIVER website for contact information.

For additional resources and product information, you may visit the AOPUTTRIVER Store on Amazon.

Related Documents - AP-886A

Preview AOPUTTRIVER AR8500 Ammonia Gas Detector User Manual and Technical Specifications
Comprehensive instruction manual for the AOPUTTRIVER AR8500 Ammonia Gas Detector. Covers product description, technical parameters, operation, maintenance, and safety precautions for this precision measurement apparatus.
Preview AOPUTTRIVER AP-570C-APP Bluetooth Connection Guide
Step-by-step instructions for connecting the AOPUTTRIVER AP-570C-APP clamp meter to your smartphone via Bluetooth. Includes troubleshooting tips for a seamless setup.
Preview 7200APP DC/AC True-RMS Digital Clamp Multimeter User Manual
User manual for the AOPUTTRIVER 7200APP DC/AC True-RMS Digital Clamp Multimeter. This auto-ranging, 6000-count meter measures amperage, voltage, capacitance, continuity, and resistance, featuring Bluetooth connectivity via the AILink app. Includes safety, operation, and maintenance details.
Preview Quick Start Guide - AOPUTTRIVER Infrared Thermometer AP-2732
Get started quickly with your AOPUTTRIVER Infrared Thermometer (AP-2732). This guide covers battery installation, basic operation, and understanding the display readings for models like the AP-2732.
Preview 6000 Counts True-RMS Auto Range Intelligent Digital AC/DC Clamp Multimeter Operation Manual
This document provides the operation manual for the AOPUTTRIVER 6000 Counts True-RMS Auto Range Intelligent Digital AC/DC Clamp Multimeter (Model AP-570S-APP), detailing its features, specifications, operating instructions, and companion AiLink mobile application.
Preview Aruba Instant AP 基本操作ガイド
Aruba Instant APデバイスの基本操作、設定、メンテナンス方法を解説する包括的なガイド。初期設定からSSID設定、ファームウェアアップデートまでを網羅。