HANMATEK HO51

Download PDFFree PDF. The Save button below keeps a bookmark and private notes in your account.

HANMATEK HO51 Portable 3-in-1 Oscilloscope, Multimeter, and Waveform Generator User Manual

Model: HO51

1. Introduction

The HANMATEK HO51 is a versatile, portable 3-in-1 device that integrates the functions of a digital oscilloscope, a multimeter, and a waveform generator. Designed for electronic troubleshooting, testing, and educational purposes, it offers a compact solution for various measurement needs. Its user-friendly interface and robust design make it suitable for both beginners and experienced professionals.

Key Features:

  • 3-in-1 Functionality: Combines an oscilloscope, multimeter, and waveform generator in a single compact unit.
  • Oscilloscope: 50 MHz bandwidth and 250 MS/s real-time sampling rate for precise waveform analysis.
  • Multimeter: Accurate measurements of voltage, current, resistance, capacitance, continuity, and diode tests.
  • Waveform Generator: Generates sine, square, triangle, and custom waveforms up to 1 MHz.
  • Portable Design: Lightweight and compact (198mm x 100mm x 39mm, 0.5 kg) for easy transport and field use.
  • Display: 3.5-inch color screen with an intuitive interface.
  • PC Software Compatibility: USB connectivity for data transfer and advanced control.
  • Power: Operates on battery or via USB power.
Diagram illustrating the 3-in-1 functionality of the HANMATEK HO51, showing separate displays for Oscilloscope, Multimeter, and Waveform Generator modes.

Image 1.1: The HANMATEK HO51's integrated Oscilloscope, Multimeter, and Waveform Generator functions.

2. Safety Information

Please read all safety instructions carefully before operating the device. Failure to follow these instructions may result in electric shock, fire, or damage to the device.

  • Do not use the device if it appears damaged or is not operating correctly.
  • Ensure proper probe connections and settings before taking measurements.
  • Do not exceed the maximum input ratings for voltage and current.
  • Use only the accessories provided or approved by HANMATEK.
  • Avoid operating the device in wet or damp conditions.
  • Disconnect power from the circuit under test before connecting or disconnecting probes.
  • Always observe local and national safety codes.

3. Package Contents

Verify that all items listed below are included in your package. If any items are missing or damaged, please contact your vendor.

  • HANMATEK HO51 Device
  • USB Cable (Type-C)
  • Passive Oscilloscope Probe
  • Multimeter Test Leads
  • Quick Start Guide
  • Probe Calibration Tool
  • Power Adapter
  • Soft Carrying Case
Image showing the HANMATEK HO51 device along with all its included accessories: USB cable, oscilloscope probe, multimeter leads, power adapter, and carrying case.

Image 3.1: HANMATEK HO51 device and included accessories.

4. Product Overview

The HANMATEK HO51 features a clear layout for easy operation. Familiarize yourself with the buttons, connectors, and display area.

4.1 Front Panel Controls and Display

Detailed diagram of the HANMATEK HO51 front panel, labeling the display area, multi-function keys (F1-F4), Mode, CH, HOR, System, Save, Trig/Δ, Auto, Measure Range, Power Switch, Stop/Run, and Multimeter Input Ports.

Image 4.1: Front panel layout and controls of the HANMATEK HO51.

  • Display Area: 3.5-inch color screen for waveform, measurement data, and menu display.
  • F1-F4 Keys: Multi-function keys, their purpose changes based on the current menu.
  • Mode Key: Switches between Oscilloscope, Multimeter, and Waveform Generator modes.
  • CH Key: Channel selection (if applicable) or related settings.
  • HOR Key: Horizontal scale adjustment for oscilloscope.
  • System Key: Accesses system settings, including language selection.
  • Save Key: Saves current waveform data or measurement results.
  • Trig/Δ Key: Trigger menu for oscilloscope or relative value key for multimeter.
  • Auto Key: Automatic setting for oscilloscope or automatic range key for multimeter.
  • Measure Range Key: Measurement menu for oscilloscope or range key for multimeter.
  • Power Switch Key: Turns the device on/off.
  • Play/Pause Key: Stops/runs oscilloscope acquisition or holds value for multimeter.
  • Navigation Keys: Up, Down, Left, Right for menu navigation and parameter adjustment.
  • Multimeter Input Ports: A, mA, COM, QVC for connecting multimeter test leads.

4.2 Side and Bottom Connectors

Images showing the side of the HANMATEK HO51 with the Type-C charging port, the rear with an expandable stand, and the device's silicone material and ABS jacket.

Image 4.2: Side view showing Type-C charging port and rear stand.

  • Type-C Charging Port: Located on the side for charging the internal battery and USB communication with a PC.
  • Probe Compensation / Signal Generator Output Connector: Located on the top side, provides a 2.5V/1KHz square wave signal for probe calibration and serves as the waveform generator output.
  • Measured Signal Input Connector (BNC): Located on the bottom for connecting the oscilloscope probe.
  • Bracket: An expandable stand on the back allows for convenient viewing angles.

5. Setup

5.1 Initial Charging

Before first use, fully charge the device using the provided USB Type-C cable and power adapter. The charging indicator will show the charging status.

5.2 Power On/Off

Press and hold the Power Switch Key (usually marked with a power symbol) to turn the device on or off.

5.3 Language Selection

Upon first startup, the device may be in a default language. To change the language:

  1. Press the System key.
  2. Navigate to the language settings (often labeled F2 or similar).
  3. Select your desired language (e.g., English) using the navigation keys and confirm.

5.4 Oscilloscope Probe Calibration

For accurate oscilloscope measurements, calibrate the passive probe before use:

  1. Connect the oscilloscope probe to the BNC input connector on the bottom of the device.
  2. Connect the probe tip to the probe compensation/signal generator output connector (1KHz square wave) on the top side of the device.
  3. Enter Oscilloscope mode (if not already there) and adjust the vertical and horizontal scales to view the square wave.
  4. Using the small calibration tool, adjust the screw on the probe connector until the square wave displayed on the screen has flat tops and bottoms with sharp corners, indicating proper compensation.

6. Operating Instructions

6.1 Switching Modes

Press the Mode key to cycle between Oscilloscope, Multimeter, and Waveform Generator functions.

6.2 Oscilloscope Operation

In Oscilloscope mode, the device displays waveforms over time. Use the following controls:

  • Vertical Scale (Volts/Div): Adjust using the navigation keys (Up/Down) when the vertical scale is highlighted.
  • Horizontal Scale (Time/Div): Press HOR and then use navigation keys (Left/Right) to adjust.
  • Trigger Settings: Press Trig/Δ to access trigger menu. Adjust trigger level, mode (Auto, Normal, Single), and type (rising/falling edge).
  • Auto Setup: Press Auto for automatic waveform scaling and positioning.
  • Run/Stop: Press the Play/Pause key to start or stop waveform acquisition.

6.3 Multimeter Operation

In Multimeter mode, the device performs various electrical measurements. Connect the multimeter test leads to the appropriate input ports (A, mA, COM, QVC).

  • Function Selection: Use the F1-F4 keys or navigation keys to select measurement functions (Voltage, Current, Resistance, Capacitance, Continuity, Diode).
  • Range Selection: Press Measure Range to manually select the measurement range, or use Auto for automatic ranging.
  • Continuity Test: Connect leads across a circuit. An audible tone indicates continuity. Note that some users have reported a slight delay in response for continuity tests.
  • Diode Test: Connect leads across a diode to measure its forward voltage drop.

6.4 Waveform Generator Operation

In Waveform Generator mode, the device outputs various signals from the probe compensation/signal generator output connector.

  • Waveform Type: Use the F1-F4 keys or navigation keys to select the desired waveform (Sine, Square, Triangle, Pulse).
  • Frequency Adjustment: Adjust the output frequency using the navigation keys.
  • Amplitude Adjustment: Adjust the output amplitude (1Vpp or 2.5Vpp) using the navigation keys.

6.5 PC Software Connectivity

Connect the HO51 to a computer via the USB Type-C port. Compatible PC software allows for data transfer, waveform analysis, and remote control of the device. Refer to the software's documentation for detailed instructions.

Image showing the HANMATEK HO51 connected to a laptop via USB, demonstrating data transfer and PC software compatibility for waveform analysis.

Image 6.1: HANMATEK HO51 connected to a PC for data export and analysis.

7. Maintenance

Proper maintenance ensures the longevity and accuracy of your HANMATEK HO51.

  • Cleaning: Use a soft, damp cloth to clean the device. Do not use abrasive cleaners or solvents. Ensure the device is powered off and disconnected from any power source before cleaning.
  • Storage: Store the device in a cool, dry place, away from direct sunlight and extreme temperatures. Use the provided carrying case for protection.
  • Battery Care: For optimal battery life, avoid fully discharging the battery frequently. If storing for extended periods, charge the battery to approximately 50% every few months.
  • Firmware Updates: Periodically check the HANMATEK official website for available firmware updates to ensure optimal performance and access to new features.

8. Troubleshooting

If you encounter issues with your HANMATEK HO51, refer to the following common problems and solutions.

  • Device does not power on:
    • Ensure the battery is charged. Connect the device to a power source using the USB-C cable and adapter.
    • Press and hold the power button for a few seconds.
  • No waveform displayed in Oscilloscope mode:
    • Check if the probe is correctly connected to the BNC input.
    • Verify the probe is properly calibrated.
    • Adjust the vertical (Volts/Div) and horizontal (Time/Div) scales.
    • Check trigger settings; try setting the trigger mode to 'Auto' or adjusting the trigger level.
    • Ensure the 'Run' state is active (not paused).
  • Multimeter readings are inaccurate or slow:
    • Ensure test leads are securely connected to the correct input ports.
    • Verify the correct measurement function and range are selected.
    • For continuity tests, allow a moment for the device to register the connection, as some users have noted a slight delay.
    • Consider performing a factory reset via the System menu if persistent issues occur.
  • Waveform generator output is incorrect:
    • Ensure the output is connected to the correct port.
    • Verify the selected waveform type, frequency, and amplitude settings.

9. Specifications

Detailed technical specifications for the HANMATEK HO51 device.

9.1 Oscilloscope Specifications

FeatureDescription
Channel1
Bandwidth50 MHz
Vertical Resolution8 bits
Sampling MethodSampling, Peak Detection
Real-time Sampling Rate250 MS/s
Waveform Refresh Rate10,000 wfms/s
Time Base Accuracy±100ppm
Input CouplingDC, AC, GND
Probe Attenuation1X, 10X, 100X, 1000X, 10000X
Maximum Input Voltage400V (DC+AC, PK-PK)
Trigger ModeAuto, Normal, Single
Trigger TypeRising Edge, Falling Edge
Coupling MethodAC / DC

9.2 Multimeter Specifications

FeatureDescription
Digital Display24,000 counts
Measurement TypeVoltage, Current, Resistance, Capacitance, Continuity, Diode
Maximum Input VoltageAC: 750V, DC: 1000V
Maximum Input CurrentAC: 10A, DC: 10A
Continuity Test< (50Ω)
Diode Test< (0-2V)
Auto RangeYes
TRMSYes

9.3 Waveform Generator Specifications

FeatureDescription
Waveform Frequencies (Sine)10Hz~100KHz
Waveform Frequencies (Square)10Hz~100KHz
Waveform Frequencies (Ramp)10Hz~100KHz
Waveform Frequencies (Pulse)10Hz~10KHz
Amplitude1Vpp or 2.5Vpp

9.4 General Specifications

FeatureDescription
Battery1 Lithium-polymer (included)
Product Dimensions (L x W x H)23 x 13.5 x 7.5 cm
Weight410 grams
Model NumberHO51
BrandHANMATEK
Power SourceBattery powered
ColorBlue
ComplianceCE

10. Warranty and Support

For warranty information, technical support, or service inquiries, please refer to the documentation included with your product or contact HANMATEK customer service directly. You may also visit the product page on Amazon for additional support resources or to contact the seller.

Amazon Product Page: HANMATEK HO51 on Amazon.com.be

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.