1. Product Overview

The Assark 620A Digital Multimeter is a compact and versatile tool designed for measuring various electrical parameters. It is suitable for technicians, hobbyists, and DIY enthusiasts for troubleshooting home, automotive, and industrial electrical issues.

  • Measures AC/DC voltage, DC current, resistance, continuity, diode, and battery levels.
  • Features a bright backlit LCD display for clear readings in various lighting conditions.
  • Equipped with a data hold function to freeze readings for convenient recording.
  • Designed with safety in mind, including overload protection and a durable rubber cover.
Assark 620A Digital Multimeter held in a hand, showing its compact size.

Image: The compact size of the Assark 620A Digital Multimeter, fitting comfortably in the palm of a hand.

2. What's in the Box

Your Assark Digital Multimeter package includes the following items:

  • 1 x Assark 620A Digital Multimeter
  • 1 x Pair of Probe Test Leads
  • 2 x 1.5V AAA Batteries
  • 1 x User Manual
Contents of the Assark Digital Multimeter package: multimeter, test leads, batteries, and user manual.

Image: A visual representation of all items included in the Assark Digital Multimeter package.

3. Product Components

Familiarize yourself with the key components of your Assark 620A Digital Multimeter:

Labeled diagram of the Assark 620A Digital Multimeter showing its parts.

Image: A detailed diagram highlighting the various parts of the multimeter, including the LCD, buttons, and input terminals.

  • 2000-Count LCD: Digital display for measurement readings.
  • Backlight Button: Activates or deactivates the display backlight.
  • Data Hold Button: Freezes the current reading on the display.
  • Function/Range Selection Switch: Rotary switch to select the desired measurement mode (e.g., Voltage, Resistance, Current, Diode, Continuity, Battery).
  • "10A" Input Terminal: Used for measuring DC currents up to 10 Amperes.
  • "VΩmA" Input Terminal: Used for measuring voltage, resistance, and milliampere/microampere currents.
  • "COM" Jack: Common terminal, always connected to the black test lead.

4. Setup and Battery Installation

Before using your multimeter, you need to install the included AAA batteries.

  1. Ensure the multimeter is turned OFF.
  2. Locate the battery compartment on the back of the multimeter.
  3. Use a screwdriver to open the battery compartment cover.
  4. Insert the two 1.5V AAA batteries, observing the correct polarity (+ and -) as indicated inside the compartment.
  5. Replace the battery compartment cover and secure it with the screw.

Connecting Test Leads:

  • Insert the black test lead into the COM (Common) jack.
  • For most measurements (voltage, resistance, diode, continuity, small currents), insert the red test lead into the VΩmA jack.
  • For measuring large DC currents (up to 10A), insert the red test lead into the 10A jack.

5. Operating Instructions

This section details how to use your multimeter for various measurements.

General Operation

  • Power On/Off: Rotate the Function/Range Selection Switch from OFF to any desired measurement function to turn on the multimeter. Rotate back to OFF to turn it off.
  • Backlight: Press the Backlight Button (sun icon) to illuminate the LCD display for better visibility in low-light conditions. Press again to turn off.
  • Data Hold: Press the HOLD Button to freeze the current reading on the display. This is useful when taking measurements in hard-to-reach areas. Press again to release the hold.
Close-up of the multimeter's backlit LCD display showing a reading of 1.999.

Image: The bright backlit LCD display of the multimeter, ensuring clear readings even in dim environments.

Measurement Modes

Always ensure the correct test lead connections and select the appropriate function on the rotary switch before taking measurements.

AC/DC Voltage Measurement (V~ / V--)

1. Connect the black lead to COM and the red lead to VΩmA.
2. Rotate the switch to the desired AC Voltage (V~) or DC Voltage (V--) range.
3. Connect the test probes across the component or circuit to be measured.

Multimeter measuring DC voltage from a 9V battery and AC voltage from a wall outlet.

Image: Demonstrates measuring DC voltage from a 9V battery and AC voltage from a power strip.

DC Current Measurement (A--)

1. Connect the black lead to COM.
2. For currents up to 200mA, connect the red lead to VΩmA. For currents up to 10A, connect the red lead to 10A.
3. Rotate the switch to the appropriate DC Current (A--) range.
4. Connect the multimeter in series with the circuit to measure current.

Note: This meter cannot test AC Current.

Resistance Measurement (Ω)

1. Connect the black lead to COM and the red lead to VΩmA.
2. Rotate the switch to the desired Resistance (Ω) range.
3. Ensure the circuit is de-energized before connecting the probes across the resistor or component.

Multimeter measuring resistance of a resistor, performing a continuity test, and a diode test.

Image: Shows the multimeter performing resistance, continuity, and diode tests.

Continuity Test (speaker icon)

1. Connect the black lead to COM and the red lead to VΩmA.
2. Rotate the switch to the Continuity (speaker icon) position.
3. Touch the probes to the two points you want to test. A continuous beep indicates a good connection (low resistance).

Diode Test (diode icon)

1. Connect the black lead to COM and the red lead to VΩmA.
2. Rotate the switch to the Diode (diode icon) position.
3. Connect the red probe to the anode and the black probe to the cathode of the diode. The display will show the forward voltage drop. Reverse the probes to check for open circuit (OL) in reverse bias.

Battery Check (BATT)

1. Connect the black lead to COM and the red lead to VΩmA.
2. Rotate the switch to the BATT position (1.5V or 9V).
3. Connect the red probe to the positive terminal and the black probe to the negative terminal of the battery. The display will show the battery voltage.

Instructional Videos

Watch these official videos for visual guidance on using your Assark Digital Multimeter.

2000 Counts Multimeter Digital Multimeter Overview

Video: A comprehensive overview demonstrating the features and basic operation of the Assark 2000 Counts Digital Multimeter.

2000 Counts Digital Multimeter Multi-meters in Use

Video: Shows the multimeter in action, performing various measurements and highlighting its ease of use.

Digital Multimeter, Ohm Voltage Meter 2000 Counts Demonstration

Video: A demonstration of the multimeter's capabilities, focusing on Ohm and voltage measurements.

6. Safety Information

Your Assark Digital Multimeter is designed with safety features. Always adhere to safety precautions when working with electrical circuits.

  • Overload Protection: The multimeter features two built-in fuses (250mA, 250V and 10A, 250V) to provide overload protection across all ranges. This helps prevent damage to the meter in case of accidental overcurrent.
  • Rubber Holster: The thick rubber cover provides good electrical insulation and absorbs impact, enhancing the durability and safety of the device.
  • Always disconnect power to the circuit before making resistance, continuity, or diode measurements.
  • Do not attempt to measure voltages or currents exceeding the specified maximum ratings of the multimeter.
  • Ensure test leads are in good condition and properly connected before use.
Internal view of the multimeter circuit board highlighting the two built-in fuses for overload protection.

Image: An illustration showing the internal fuses of the multimeter, which provide overload protection.

7. Troubleshooting

Here are some common issues and their solutions:

ProblemIndicationSolution
Over RangeDisplay shows "OL"The measured value exceeds the selected range. Rotate the switch to a higher range or a different function.
Negative PolarityDisplay shows a "-" signThe test leads are connected with reversed polarity. This is normal for DC measurements; simply note the negative sign.
Low BatteryBattery icon appears on displayThe batteries are low. Replace the two 1.5V AAA batteries immediately to ensure accurate readings.
No Display/No PowerScreen is blank when turned onCheck battery installation and ensure batteries are not depleted. Verify the rotary switch is not in the OFF position.

8. Specifications

AttributeDetail
Model Number620A
BrandAssark
Product Dimensions3.94 x 1.97 x 1.1 inches
Item Weight0.18 Kilograms (6.35 ounces)
Power SourceBattery Powered (2 x 1.5V AAA batteries)
Display2000 Counts LCD with Backlight
ManufacturerAssark
Country of OriginChina

9. Warranty and Support

For warranty information or technical support, please refer to the contact details provided in the original product packaging or visit the official Assark website. Keep your purchase receipt as proof of purchase for any warranty claims.

For additional resources and product information, you may visit the Assark Store on Amazon.

© 2024 Assark. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.