Jopwkuin Temperature Detector Instruction Manual

Model: Jopwkuin0qdh4kfbzp

1. Introduction

This instruction manual provides detailed information on the operation, maintenance, and specifications of the Jopwkuin Temperature Detector. This device is designed for accurate temperature measurement in various applications, including liquids and air, utilizing K and J type thermocouples. Please read this manual thoroughly before using the device to ensure proper and safe operation.

Jopwkuin Temperature Detector main unit

Figure 1: The Jopwkuin Temperature Detector, showcasing its compact design and display screen.

2. Key Features

  • Universal Compatibility: Equipped with K and J type sockets, this thermocouple temperature meter is compatible with K and J type plugs for easy insertion and removal of various probes.
  • Data Locking: The device allows for locking of data, including maximum, minimum, average, and real-time values during the measurement process, ensuring accuracy and convenience for data analysis.
  • Customizable Alarm Thresholds: Users can set upper and lower limit alarm values. The screen's red backlight will illuminate with a steady light if measurements exceed or fall below the configured thresholds, providing immediate alerts.
    Temperature detector screen showing alarm thresholds

    Figure 2: The device display indicating customizable alarm thresholds and the red backlight alert feature.

  • Temperature Compensation: This feature allows for the correction of temperature variances from actual standard temperatures through ADJ temperature compensation, adjustable within a range of -9 to +9℃.
    Temperature detector showing temperature compensation feature

    Figure 3: The device displaying the temperature compensation adjustment feature.

  • Versatile Temperature Probes: Supports various K and J type temperature probes, offering options for liquid, air, surface, and general temperature measurements based on the object being tested.
    Temperature detector with probe measuring liquid temperature

    Figure 4: The temperature detector in use, demonstrating its capability to measure ambient or liquid temperatures with a connected probe.

3. Setup Guide

3.1. Battery Installation

The Jopwkuin Temperature Detector requires two 1.5V AAA batteries (not included). Follow these steps to install the batteries:

  1. Locate the battery compartment cover on the back of the device.
  2. Slide the cover open in the direction indicated by the arrow.
  3. Insert two AAA batteries, ensuring correct polarity (+ and -) as marked inside the compartment.
  4. Close the battery compartment cover securely.
Open battery compartment of the temperature detector

Figure 5: Close-up view of the battery compartment, showing where to insert the AAA batteries.

3.2. Connecting a Thermocouple Probe

The device supports K and J type thermocouple probes. To connect a probe:

  1. Identify the K or J type thermocouple probe you intend to use.
  2. Locate the input sockets on the side of the temperature detector. These are typically marked with '+' and '-' or K/J type indicators.
  3. Carefully insert the probe's plug into the corresponding socket, ensuring a firm connection.
Close-up of thermocouple input ports on the temperature detector

Figure 6: Detail of the K/J type thermocouple input ports on the side of the device.

Temperature detector with included probe and carrying pouch

Figure 7: The temperature detector alongside its included K-type thermocouple probe and carrying pouch.

4. Operating Instructions

4.1. Powering On/Off

  • To power on the device, press the Power button (usually marked with a circle and vertical line).
  • To power off, press and hold the Power button for a few seconds until the display turns off. The device also features an automatic shutdown function after 10 minutes of inactivity to conserve battery life. This can typically be disabled or enabled via specific button combinations (refer to on-screen prompts if available).

4.2. Taking Measurements

  • Ensure a thermocouple probe is securely connected.
  • Place the tip of the probe into or onto the substance/area you wish to measure.
  • The temperature reading will be displayed on the screen. The sampling rate is approximately 1 time per second.

4.3. Data Locking (MAX/MIN/AVG/HOLD)

The device provides functions to capture and review specific data points:

  • Press the MAX button to display the maximum temperature recorded since the device was powered on or the function was reset.
  • Press the MIN button to display the minimum temperature recorded.
  • Press the HOLD button to freeze the current temperature reading on the display. Press again to release.
  • The average (AVG) value may be accessible through a combination of buttons or a dedicated button, depending on the model. Consult the on-screen interface for specific instructions.

4.4. Setting Alarm Thresholds

To set custom high and low temperature alarms:

  1. Access the alarm setting mode (typically by pressing a dedicated alarm button or a combination of buttons like SET or MODE).
  2. Use the navigation buttons (e.g., UP/DOWN or +/-) to adjust the upper limit (High Alarm) and lower limit (Low Alarm) values. Default values are 1300℃ for High Alarm and -200℃ for Low Alarm.
  3. Confirm your settings (often by pressing the SET or ENTER button).
  4. When the measured temperature exceeds the upper limit or falls below the lower limit, the screen's red backlight will activate as an alert.

4.5. Temperature Compensation (ADJ)

To adjust for minor temperature variances:

  1. Enter the ADJ temperature compensation mode (refer to the device's on-screen menu or specific button press sequence).
  2. Adjust the compensation value within the range of -9 to +9℃ to fine-tune readings.
  3. Save the setting.

5. Maintenance

5.1. Cleaning

  • Wipe the device's exterior with a soft, dry cloth.
  • Do not use abrasive cleaners or solvents.
  • Ensure the probe is clean before and after each use, especially when measuring different substances.

5.2. Storage

  • When not in use for extended periods, remove the batteries to prevent leakage and damage to the device.
  • Store the device in a cool, dry place, away from direct sunlight and extreme temperatures.
  • Storage Environment: -10 to 50 ℃, maximum relative humidity of 70% (with battery removed).

6. Troubleshooting

ProblemPossible CauseSolution
Device does not power on.Batteries are dead or incorrectly installed.Replace batteries with new 1.5V AAA batteries, ensuring correct polarity.
Inaccurate temperature readings.
  • Probe not properly connected.
  • Incorrect probe type for application.
  • Probe is damaged.
  • Need for temperature compensation.
  • Ensure probe is securely connected to the correct input.
  • Verify the probe type (K or J) matches the measurement requirement.
  • Replace the probe if damaged.
  • Use the ADJ temperature compensation feature to calibrate.
Alarm backlight is constantly on.Measured temperature is outside set alarm thresholds.Adjust the upper and lower alarm limits to suit your measurement range, or move the probe to an area within the acceptable temperature range.
Display shows "APO" or turns off unexpectedly.Automatic Power Off (APO) function activated due to inactivity.Press the power button to turn the device back on. If frequent, consider disabling APO if the model allows.

7. Technical Specifications

ParameterValue
Measurement ChannelSingle channel
Measurement Range (K Type)-200 to +1372 ℃ (-328 to +2501 ℉)
Measurement Range (J Type)-200 to +1372 ℃ (-328 to +2501 ℉)
AccuracyΒ± 0.2% + 0.7 ℃
Resolution (-100 to 200 ℃)1 ℃ / 1 ℉
Resolution (-99 to 999.9 ℃)0.1 ℃ / 1 ℉
Resolution (β‰₯ 1000 ℃)1 ℃ / 1 ℉
Environmental Temperature Range0 to 60 ℃
Environmental Temperature AccuracyΒ± 2 ℃
Temperature DisplayFour digit display, maximum 9999
High Alarm (Default)1300 ℃
Low Alarm (Default)-200 ℃
ADJ Temperature Compensation-9 to +9 ℃
Sampling Rate1 time/second
Automatic Shutdown10 minutes (can be manually turned off)
Operating Environment-10 to 50 ℃, maximum 80% relative humidity, indoor altitude
Storage Environment-10 to 50 ℃, maximum 70% relative humidity (battery removed)
K Type Thermocouple (Randomly Configured)Measurement range: -20 to 200 ℃ (accuracy Β± 2.5%)
Battery2 x 1.5V AAA battery (not included)
Package Dimensions7.87 x 3.15 x 1.97 inches
Item Weight6.56 ounces

8. Warranty and Support

For warranty information and technical support, please refer to the documentation included with your purchase or contact Jopwkuin customer service. Keep your purchase receipt as proof of purchase for any warranty claims.

For further assistance, you may visit the official Jopwkuin store on Amazon: Jopwkuin Store.

9. Product Videos

There are no official product videos provided by the seller for this model at this time.

© 2024 Jopwkuin. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.