Rola-Chem RC301MC
Rola-Chem Pro Series 300 Pump RC301MC User Manual
Model: RC301MC
Introduction
The Rola-Chem Pro Series 300 Peristaltic Pump RC301MC is designed for precise and reliable fluid dosing in various applications. This manual provides essential information for the safe and efficient installation, operation, and maintenance of your pump.
Key features include a new commercial design, a fully digital timer, refined dosing increments for precise control, and versatile mounting options. It also features a quick-release cover for tubing access, a three-way switch for timer/off/continuous modes, and self-priming capabilities with clear Tygon and Black Norprene Squeeze Tubes.
Safety Information
Always observe the following safety precautions to prevent injury or damage to the equipment:
- Read all instructions thoroughly before installation and operation.
- Ensure the power supply matches the pump's voltage requirements (120V for this model).
- Disconnect power before performing any maintenance or service.
- Do not operate the pump with damaged cords or tubing.
- Keep the pump away from excessive moisture or direct water spray unless specifically designed for such environments.
- Handle chemicals with appropriate personal protective equipment.
Product Overview
The Pro Series 300 Pump is a compact and efficient dosing pump. Below is an image illustrating the main components:

Image: Rola-Chem Pro Series 300 Pump showing the main unit, digital display, control buttons, pump head with clear tubing, and connection fittings.
Key Components:
- Pump Head: Houses the rollers and tubing for peristaltic action.
- Digital Timer: For precise control of dosing cycles.
- Control Panel: Buttons for setting timer, mode (off/continuous).
- Tubing: Clear Tygon and Black Norprene Squeeze Tubes for fluid transfer.
- Mounting Options: Versatile design for various installation scenarios.
Setup
Follow these steps for initial setup:
- Choose Mounting Location: Select a stable, dry location near the chemical source and injection point. The pump offers versatile mounting options.
- Mount the Pump: Securely attach the pump to the chosen surface using appropriate hardware. Ensure it is level and stable.
- Connect Tubing:
- Connect the suction tubing (clear Tygon) to the chemical source. Ensure the tubing reaches the bottom of the chemical container.
- Connect the discharge tubing (Black Norprene) from the pump head to the injection point.
- Ensure all connections are secure to prevent leaks.
- Power Connection: Plug the 120V power cord into a grounded electrical outlet.
- Prime the Pump: The pump is self-priming. To ensure proper operation, run the pump in continuous mode until fluid is visible flowing through the discharge tubing.
Operating Instructions
The Pro Series 300 Pump features a three-way switch and a fully digital timer for precise control.
- Power On/Off: Use the main power switch to turn the pump on or off.
- Mode Selection: The three-way switch controls the operating mode:
- Timer: Activates the digital timer for programmed dosing cycles.
- Off: Turns the pump off.
- Continuous: Runs the pump continuously for priming or extended dosing.
- Setting the Digital Timer:
- Refer to the pump's digital display and control buttons.
- Use the 'MODE' button to navigate through settings.
- Adjust dosing increments and cycle times as needed. Pumps operate on 9-minute cycles.
- Consult the on-screen prompts for specific programming steps.
- Dosing Increments: The refined dosing increments allow for more precise control over chemical delivery. Adjust these settings based on your application's requirements.
Maintenance
Regular maintenance ensures optimal performance and extends the life of your pump.
- Tubing Replacement: Periodically inspect the clear Tygon and Black Norprene Squeeze Tubes for wear, cracks, or discoloration. Replace tubing as necessary to maintain dosing accuracy and prevent leaks. The quick-release cover provides fast tubing access.
- Clean Pump Head: Keep the pump head clean and free of debris. Wipe down the exterior with a damp cloth. Do not use abrasive cleaners.
- Check Connections: Regularly inspect all tubing connections and fittings for tightness and signs of leakage.
- Storage: If storing the pump for an extended period, ensure it is clean and dry. Store in a cool, dry place away from direct sunlight.
Troubleshooting
This section addresses common issues you might encounter with your Pro Series 300 Pump.
| Problem | Possible Cause | Solution |
|---|---|---|
| Pump not running | No power; Switch in 'Off' position; Motor fault | Check power connection; Ensure switch is in 'Timer' or 'Continuous' mode; Contact support if motor fault suspected. |
| No fluid being pumped | Tubing kinked or blocked; Air in line; Chemical tank empty; Worn tubing | Check and clear tubing; Re-prime the pump; Refill chemical tank; Replace worn tubing. |
| Inaccurate dosing | Incorrect timer settings; Worn tubing; Air bubbles in line | Verify timer settings; Replace worn tubing; Ensure proper priming and no air leaks. |
| Leakage from pump head | Damaged tubing; Loose connections | Inspect and replace tubing; Tighten all connections. |
Specifications
| Feature | Detail |
|---|---|
| Model Number | RC301MC (543808) |
| Brand | Rola-Chem |
| Power Source | Corded Electric, 120V |
| Maximum Amps | 2.5A |
| Pressure Rating | 30 psi |
| Suction Lift | 18 ft. (versatile) |
| Cycle Operation | 9-minute cycles |
| Material | Plastic |
| Package Dimensions | 10.7 x 10.6 x 10.2 inches |
| Item Weight | 6.3 Pounds |
| UPC | 757706000284 |
Warranty and Support
For warranty information and technical support, please refer to the documentation included with your purchase or visit the official Rola-Chem website. Keep your purchase receipt for warranty claims.
For further assistance, you may contact Rola-Chem customer service directly.
Ask a question about this manual
Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.