Introduction

Thank you for purchasing the AIRMATE 26-inch Electric Space Heater. This manual provides important information regarding the safe operation, installation, maintenance, and troubleshooting of your new heater. Please read this manual thoroughly before use and keep it for future reference.

Important Safety Instructions

When using electrical appliances, basic precautions should always be followed to reduce the risk of fire, electric shock, and injury to persons, including the following:

Image showing multiple safety features of the Airmate heater, including power cut-off, overheat protection, 0° frost protection, and flame retardant material, with a child playing nearby.
Figure 1: Multiple Safety Protections. The heater is designed with power cut-off, overheat protection, 0° frost protection, and flame retardant materials to ensure safe operation.

Product Overview

The AIRMATE 26-inch Electric Space Heater is a powerful and efficient heating solution for indoor spaces. It features PTC ceramic heating technology for rapid warmth, 70° oscillation for wide heat distribution, and multiple safety mechanisms.

Key Features:

Front view of the Airmate 26-inch electric space heater, showing its sleek design.
Figure 2: Airmate 26-inch Electric Space Heater.
Image highlighting the instant 2-second heating capability of the Airmate PTC ceramic heater.
Figure 3: Instant 2-second heating. The powerful PTC ceramic heating technology provides rapid warmth.

Setup

  1. Unpacking: Carefully remove the heater from its packaging. Retain packaging for storage or future transport.
  2. Placement: Place the heater on a firm, level surface. Ensure there is at least 3 feet (0.9 meters) of clear space around the heater from walls, furniture, and other objects. Do not place the heater on soft surfaces like beds or thick carpets where air inlets or outlets could be blocked.
  3. Power Connection: Ensure the heater is switched off before plugging it into a standard 220-240V AC electrical outlet. Do not use extension cords or power strips with this heater.
  4. Initial Use: Upon first use, a slight odor may be present. This is normal and will dissipate quickly.
Image showing the Airmate heater in a bedroom setting, illustrating its use in larger rooms and quiet operation.
Figure 4: Heater placement in a room. Ensure adequate clearance around the unit for optimal performance and safety, especially in larger rooms.

Operating Instructions

The heater features intuitive controls for easy operation. Refer to the control panel for mode selection, oscillation, and timer settings.

Control Panel:

The control panel is located on the top of the unit. It typically includes buttons or knobs for Power, Mode, Oscillation, and Timer.

Top view of the Airmate heater showing the control panel and indicating 70 degree oscillation for extended heat coverage.
Figure 5: Control panel and 70° oscillation feature. The top panel allows selection of modes and oscillation for wide heat distribution.

Power On/Off:

Mode Selection:

Cycle through the available modes using the Mode button:

Image showing the Airmate heater in a living room setting, highlighting the adjustable thermostat with 2000W Hot, 1000W Warm, and 17W Breeze modes. Also depicted are the removable dust filter, stable chassis, and metal mesh cover.
Figure 6: Adjustable thermostat and power modes. This image illustrates the heater's operational modes (Cold Air, Warm Air, Hot Air) and also highlights features like the removable dust filter, stable chassis, and protective metal mesh cover.

Oscillation Function:

Timer Setting:

Maintenance

Regular cleaning and maintenance will ensure optimal performance and extend the lifespan of your heater.

Cleaning the Heater:

  1. Always unplug the heater and allow it to cool completely before cleaning.
  2. Wipe the exterior surfaces with a soft, damp cloth. Do not use abrasive cleaners or solvents.
  3. Ensure no water enters the interior of the heater.

Cleaning the Removable Dust Filter:

The heater is equipped with a removable dust filter (see Figure 6 for location) for easy cleaning.

  1. Locate the filter cover on the back or side of the heater.
  2. Gently remove the filter cover and pull out the filter.
  3. Clean the filter with a soft brush or vacuum cleaner to remove dust and debris. If heavily soiled, rinse with lukewarm water and allow it to air dry completely before reinserting.
  4. Reinsert the dry filter and replace the cover.

Troubleshooting

If your heater is not operating correctly, please refer to the following common issues and solutions:

ProblemPossible CauseSolution
Heater does not turn on.
  • Not plugged in.
  • Power outlet not working.
  • Overheat protection activated.
  • Tip-over protection activated.
  • Ensure the power cord is securely plugged into a working electrical outlet.
  • Check the circuit breaker or try a different outlet.
  • Unplug the heater, wait 30 minutes for it to cool down, then plug it back in.
  • Ensure the heater is on a flat, stable surface. If it tipped over, place it upright.
Heater produces insufficient heat.
  • Incorrect mode selected.
  • Dust filter is clogged.
  • Room size too large for selected mode.
  • Ensure "Hot Air" (2000W) mode is selected for maximum heat.
  • Clean the removable dust filter as described in the Maintenance section.
  • Consider using the heater in a smaller room or allowing more time for heating.
Heater makes unusual noise.
  • Obstruction in fan.
  • Heater not on a level surface.
  • Unplug the heater and inspect for any foreign objects. Do not attempt to disassemble.
  • Ensure the heater is placed on a stable, flat surface.

Specifications

BrandAirmate
Model NumberHP20114-GA-3-W
Power Output2000W (Max)
Voltage220-240V AC
Heating ElementPTC Ceramic
ModesCold Air (17W), Warm Air (1000W), Hot Air (2000W)
Oscillation Angle70°
TimerUp to 12 hours
Dimensions (L x W x H)22.6 x 22.6 x 64.7 cm (8.9 x 8.9 x 25.5 inches)
Weight6.15 kg (13.56 lbs)
MaterialABS (Flame Retardant)
Safety FeaturesOverheat Protection, Tip-Over Protection, Metal Mesh Cover

Warranty and Customer Support

For warranty information or if you encounter any issues not covered in this manual, please contact AIRMATE customer support. Please have your model number (HP20114-GA-3-W) and purchase details ready.

Contact information can typically be found on the product packaging or the official AIRMATE website.

Related Documents - HP20114-GA-3-W

Preview AIRMATE PTC Ceramic Heater User Manual - HP15114-G-1/HP15114-G-2
Comprehensive user manual for the AIRMATE PTC Ceramic Heater, models HP15114-G-1 and HP15114-G-2. Includes care maintenance, specifications, safety instructions, product parts, and operating guide.
Preview Airmate AIR6-G Baseboard Heater User Manual
User manual for the Airmate AIR6-G Baseboard Heater, providing instructions for operation, safety precautions, maintenance, and product specifications. Features include humidification and flame effects.
Preview AirMate FD4028 16" Desk Fan: Instructions Manual
Comprehensive instructions manual for the AirMate FD4028 16-inch (40cm) Desk Fan, covering important safety precautions, assembly, operation, maintenance, and specifications.
Preview Airmate YS40A 16" (40cm) Stand Fan Instructions Manual
This document provides important instructions, parts description, assembly method, operations, safety precautions, maintenance, troubleshooting, and specifications for the Airmate YS40A 16" (40cm) Stand Fan.
Preview AIRMATE AIR4-F-1/AIR4-F-2 Bladeless Fan Instruction Manual
Comprehensive instruction manual for the AIRMATE AIR4-F-1 and AIR4-F-2 bladeless fans, covering setup, operation, safety precautions, maintenance, and specifications.
Preview AirMATE Anti-Decubitus Tubular Mattress with Pump User Manual
User manual for the AirMATE anti-decubitus tubular mattress with Soft Wind III compressor. Provides instructions on setup, usage, safety, and maintenance for preventing and treating bedsores.