1. Introduction and Overview

The MECHEER JK-PM07-US Watt Meter is designed to monitor the electricity usage of home appliances, helping users track power consumption and manage energy costs. This device offers multiple display modes and features for comprehensive energy monitoring.

2. Product Specifications

SpecificationValue
Operating Voltage120 V/60 Hz
Power Display Range0.5W-2900W
Operation CurrentMax 13A
Total Power Display0.0kWh-9999kWh
Total Cost Display0.0£-9999£ (Note: Currency symbol may vary based on region/firmware)
Voltage Accuracy±1%
Current Accuracy±2%
Power Accuracy±2%
Electrical Cost Setting Range00.00£/kWh - 99.99£/kWh (Note: Currency symbol may vary based on region/firmware)
Item Weight13.4 ounces
Product Dimensions5.2 x 2.7 x 2.4 inches
Diagram showing the dimensions of the MECHEER Watt Meter, 5.19 inches tall, 2.44 inches wide, and 1.31 inches deep when plugged in.
Figure 1: Product dimensions and key specifications.

3. Setup

  1. Unpack the MECHEER Watt Meter from its packaging.
  2. Plug the watt meter into a standard 120V/60Hz wall outlet.
  3. Plug the appliance you wish to monitor into the watt meter's socket.
  4. The display will illuminate, and the device is ready for use.

4. Operating Instructions

4.1. 8 Display Modes

The watt meter features 8 display modes to show different measured data. Press the "MODE" button to cycle through the modes.

Image showing the MECHEER Watt Meter display with 8 different modes, each showing various electrical parameters like cumulative time, apparent power, active power, cumulative electrical quantity, electricity bill, voltage, frequency, current, power factor, min power, max power, overload alarm, KWH alarm, and price.
Figure 2: Overview of the 8 display modes.

4.2. Overload Settings

The default overload power is 3680W. It is recommended to set this to 1800W for typical US household use to prevent overloading circuits.

  1. Press and hold the "MODE" button for more than 3 seconds to enter the overload settings.
  2. Press the "MODE" button to select the digit location you wish to change.
  3. Use the "UP/CLK" and "DOWN" buttons to adjust the digits to the desired overload value (e.g., 1800W).
  4. Press the "SET" button to save the overload setting.
Image showing the MECHEER Watt Meter displaying 'Overload 1800W' with a red lightning bolt icon, indicating the overload protection feature in action.
Figure 3: Overload protection display.

4.3. Electricity Price Settings

Set the cost per kilowatt-hour (kWh) to accurately calculate electricity bills.

  1. Press and hold the "SET" button for 3 seconds to enter the electricity price setting mode.
  2. Press the "MODE" button to select the digit location.
  3. Use the "UP/CLK" and "DOWN" buttons to set the numbers for your electricity cost per kWh.
  4. Press the "SET" button to save the price settings.
Image showing the MECHEER Watt Meter plugged into a wall outlet, monitoring a refrigerator, with the display showing cumulative electrical quantity (0.013 kWh) and electricity bill (0.07 Cost).
Figure 4: Monitoring electricity cost for an appliance.

4.4. KWH Alarm Settings

Configure an alarm to be notified when a specific cumulative kWh consumption is reached.

  1. Press and hold the "DOWN" button for 3 seconds to enter the KWH alarm setting mode.
  2. Press the "MODE" button to select the digit location.
  3. Use the "UP/CLK" and "DOWN" buttons to set the desired KWH alarm value.
  4. Press the "SET" button to save the KWH alarm settings.

4.5. Button Sound Settings

Turn the button press sound on or off.

4.6. Backlight On/Off and Time Settings

Control the backlight for better visibility and adjust its duration.

Two images of the MECHEER Watt Meter display, one showing the backlight off (marked with X) and the other showing the backlight on (marked with a checkmark), illustrating the easy-to-read feature.
Figure 5: Backlight display for easy reading.

4.7. Data Memory Function

The device automatically saves all cumulative data and settings.

Image illustrating the data memory function, showing the MECHEER Watt Meter plugged into a power strip, with a toaster connected. A cloud icon with a checkmark indicates data saving, and a hand is shown pressing the reset button on the meter.
Figure 6: Data memory function in action.

4.8. Data Clear Function

Clear all cumulative data (kWh, cost, and total time data).

4.9. Reset Function

Reset the power meter to its default factory settings, clearing all data.

4.10. Operation Guide Video

For a visual guide on operating the MECHEER Watt Meter, please watch the official video below:

Video 1: Operation Guide for MECHEER Power Meter Plug. This video demonstrates the various display modes, setting overload limits, electricity prices, KWH alarms, button sounds, backlight options, data memory, data clearing, and reset functions.

5. Maintenance

6. Troubleshooting

7. Safety Information

8. Warranty and Support

MECHEER products are designed for reliability and performance. For warranty information, technical support, or service inquiries, please refer to the contact information provided with your purchase or visit the official MECHEER website.

Please retain your proof of purchase for warranty claims.

Related Documents - JK-PM07-US

Preview Power Meter User Manual: Monitor Electricity Usage and Cost
Comprehensive user manual for the Power Meter, detailing its features for monitoring electricity consumption, calculating costs, managing overload protection, and adjusting settings for home appliances.
Preview Techbee JK-PM04 Power Monitor User Manual: Features, Safety, and Operation
Comprehensive user manual for the Techbee JK-PM04 Power Monitor. Learn about its features, safety precautions, setup, and how to monitor electricity usage, cost, and carbon emissions.
Preview JIKONG Lithium Battery Smart Protection Board Specification and Operation Manual
Comprehensive specification and operation manual for JIKONG lithium battery smart protection boards, covering technical parameters, interface descriptions, installation, operation, safety measures, and APP control. Includes warranty and copyright information.
Preview JIKONG BMS: Advanced Battery Management Systems - Models, Specs, and Features
Explore the comprehensive range of JIKONG Battery Management Systems (BMS) including JK-BD, JK-B1, JK-B2, and JK-BD6A series. This document details specifications, features like active balancing, superior heat dissipation, communication protocols, installation guides, and diverse application scenarios for lithium battery systems.
Preview JIKONG JK-BD4A8S Lithium Battery Active Balancing Protection Board Manual
Comprehensive user and maintenance manual for the JIKONG JK-BD4A8S series Lithium battery active balancing protection boards, detailing features, specifications, installation, and APP operation.