1. Introduction
This manual provides essential information for the safe and efficient operation of your Tuncmatik TSK10091 Newtech Pro3 One 1 KVA On-Line LCD Uninterruptible Power Supply (UPS). Please read this manual thoroughly before installation and operation, and retain it for future reference. This UPS is designed to provide continuous, clean power to your critical electronic equipment.
2. Safety Instructions
Observe the following safety precautions to prevent injury and damage to the UPS or connected equipment:
- Do not open the UPS casing. There are no user-serviceable parts inside. Refer all servicing to qualified personnel.
- Do not connect non-computer related items such as medical equipment, life support equipment, or household appliances to the UPS.
- Ensure the UPS is connected to a grounded power outlet.
- Avoid placing the UPS in direct sunlight, near heat sources, or in environments with excessive dust, humidity, or corrosive substances.
- Ensure adequate ventilation around the UPS. Do not block ventilation openings.
- In case of fire, use a dry chemical extinguisher. Water can cause electrical shock.
- Disconnect the UPS from the AC power source before cleaning. Use a dry cloth for cleaning.
3. Package Contents
Upon unpacking, please verify that the following items are included:
- Tuncmatik TSK10091 Newtech Pro3 One 1 KVA On-Line LCD UPS Unit
- User Manual (this document)
- Power Cables (may vary by region)
4. Product Overview
The Tuncmatik TSK10091 Newtech Pro3 One is a 1 KVA (1000 Watts) On-Line Uninterruptible Power Supply designed to protect your sensitive electronics from power fluctuations and outages. It features a high-performance microprocessor, intelligent charging technology for optimal battery life, and provides a full sine wave output. The integrated LCD display offers real-time status information.

Figure 4.1: Front view of the Tuncmatik TSK10091 UPS, showing the LCD display and control buttons.
Key Features:
- High performance microprocessor for precise control.
- Input power factor correction for improved efficiency.
- Intelligent charging technology for extended battery lifespan.
- True On-Line double conversion technology for continuous, clean power.
- High output power factor.
- Full sine wave output, compatible with all types of electronic loads.
- LCD display for real-time status monitoring.
5. Setup
- Placement: Place the UPS on a stable, flat surface in a well-ventilated area, away from direct sunlight, heat, and moisture. Ensure there is sufficient space around the unit for airflow.
- Initial Charging: Before connecting any equipment, plug the UPS into a standard grounded wall outlet. Allow the UPS to charge for at least 8 hours to ensure the internal batteries are fully charged. The LCD display will indicate charging status.
- Connecting Equipment: After initial charging, connect your critical equipment (e.g., computer, monitor, network devices) to the output receptacles on the rear of the UPS. Ensure the total load does not exceed the UPS's rated capacity (1000 Watts).
- Power On: Press and hold the power button (typically labeled "ON" or with a power symbol) on the front panel until the UPS powers on and the LCD display illuminates.
6. Operating Instructions
The TSK10091 UPS is designed for user-friendly operation. The LCD display provides critical information about the UPS status.
6.1. LCD Display and Control Panel
The front panel features an LCD display and several control buttons. The LCD provides real-time information such as input/output voltage, battery level, load percentage, and operational status. Refer to the image in Section 4 for button locations.
- ON Button: Press to turn on the UPS.
- OFF Button: Press to turn off the UPS.
- SELECT Button: Use to cycle through different display parameters on the LCD.
- Alarm/Mute Button (often combined with another function): May be used to silence audible alarms.
6.2. Normal Operation
When connected to AC power, the UPS operates in On-Line mode, continuously conditioning the power and charging the batteries. In the event of a power outage, the UPS will automatically switch to battery power without interruption.
6.3. Battery Mode
When AC input power is lost, the UPS will automatically transfer to battery power. An audible alarm may sound, and the LCD will indicate battery mode. The duration of battery backup depends on the connected load. When AC power is restored, the UPS will automatically switch back to AC mode and begin recharging its batteries.
7. Maintenance
Proper maintenance ensures the longevity and optimal performance of your UPS.
- Battery Care: To maximize battery life, avoid frequent deep discharges. If the UPS is stored for an extended period, recharge it every 3 months for at least 8 hours.
- Cleaning: Keep the UPS clean and free of dust. Use a dry, soft cloth to wipe the exterior. Do not use liquid or aerosol cleaners.
- Ventilation: Regularly check that the ventilation openings are not obstructed to prevent overheating.
- Environmental Conditions: Operate the UPS within its specified temperature and humidity ranges.
8. Troubleshooting
This section addresses common issues you might encounter with your UPS. If the problem persists, contact customer support.
| Problem | Possible Cause | Solution |
|---|---|---|
| UPS does not turn on. | No AC input power; Battery discharged; Power button not pressed correctly. | Check AC power connection; Allow UPS to charge for 8 hours; Press and hold the ON button firmly. |
| UPS is in battery mode frequently. | Unstable AC input power; Overload. | Check AC power quality; Reduce connected load. |
| Short backup time. | Batteries not fully charged; Batteries reaching end of life; Overload. | Ensure full charge; Consider battery replacement if old; Reduce connected load. |
| Loud fan noise. | Normal operation under load; Dust accumulation; Fan malfunction. | Fan speed may increase with load; Clean ventilation openings; If excessive and persistent, contact support. |
| LCD display is blank. | UPS is off; Display sleep mode. | Turn on the UPS; Press any button to wake the display. |
9. Specifications
| Feature | Specification |
|---|---|
| Brand | Tuncmatik |
| Model | TSK10091 |
| Output Wattage | 1000 Watts |
| Item Weight | 10.34 Kilograms |
| Parcel Dimensions (L x W x H) | 37.29 x 33.1 x 23 cm |
| Technology | On-Line Double Conversion |
| Output Waveform | Full Sine Wave |
| Batteries Included | No (Internal batteries are typically sealed lead-acid and integrated) |
10. Warranty and Support
For warranty information and technical support, please refer to the warranty card included with your product or visit the official Tuncmatik website. Keep your purchase receipt as proof of purchase for warranty claims. Do not attempt to repair the unit yourself, as this may void your warranty and pose a safety risk.
For further assistance, please contact Tuncmatik customer service.