1. Introduction
This manual provides essential instructions for the safe and efficient operation, maintenance, and troubleshooting of your AIVOLT 11250 Watt Dual Fuel Inverter Generator, Model VS12000411. Please read this manual thoroughly before operating the generator to ensure proper use and to prevent injury or damage.
The AIVOLT 11250 Watt Dual Fuel Inverter Generator is designed to provide reliable power using either gasoline or propane, making it suitable for various applications including home backup, RV use, and job sites. It features a powerful engine, multiple outlets, and safety mechanisms to ensure stable and secure power delivery.

Figure 1.1: AIVOLT 11250 Watt Dual Fuel Inverter Generator.
2. Safety Information
WARNING: Failure to follow these safety instructions could result in serious injury or death.
- Carbon Monoxide Hazard: Generators produce carbon monoxide (CO), an odorless, colorless, poisonous gas. Operate the generator outdoors only, far away from windows, doors, and vents. Never operate indoors or in partially enclosed spaces. The generator is equipped with a CO alert system that will shut down the unit if CO levels become too high.
- Fire Hazard: Gasoline and propane are highly flammable. Refuel only when the engine is off and cool. Do not smoke near the generator. Store fuel in approved containers in a well-ventilated area.
- Electrical Shock Hazard: Do not operate the generator in wet conditions. Ensure all connections are secure and dry. Do not overload the generator.
- Hot Surfaces: The generator's engine and muffler become very hot during operation and remain hot for some time after shutdown. Avoid contact with hot surfaces.
- Engine Oil: Check engine oil level before each use. The generator features a low-oil shutoff to protect the engine.
- Overload Protection: The generator is equipped with overload protection that will shut down the unit if overloaded. Reduce the load before restarting.
- EPA & CARB Compliant: This generator meets U.S. environmental and safety regulations, including EPA and CARB compliance. It is approved for sale and use in all 50 states, including California.
3. Product Overview
3.1. Main Components
- Engine (459cc, 4-stroke)
- Fuel Tank (7.1 Gallon / 27 Liter capacity)
- Control Panel with various outlets and indicators
- Wheels (Two 9-inch silent rubber wheels for portability)
- Handle for transport
- Muffler
3.2. Control Panel
The control panel provides access to all operational controls and output receptacles. Familiarize yourself with each component before operation.

Figure 3.1: Detailed view of the generator control panel.
- Fuel Switch: Selects between Gasoline (FUEL ON) and Propane (LPG INLET).
- Power Switch: Controls the main power to the generator.
- Start Up Switch: Used for manual starting.
- Low Idle / Eco Mode Switch: Engages Eco Mode for fuel efficiency.
- Voltage Selector Switch: Selects output voltage (e.g., 120V/240V).
- LCD Display Center: Shows hours, voltage, frequency, power output (kW), fuel level, and oil level.
- CO Indicator: Illuminates if carbon monoxide levels are detected.
- ATS Outlet: Automatic Transfer Switch outlet for home backup connection.
- Parallel Outlet: For connecting two generators in parallel (requires separate kit).
- Circuit Breakers: Protects outlets from overload (20A, 30A, 50A).
- AC 120V Outlets: Standard household outlets.
- AC 120V 20A GFCI Outlet: Ground Fault Circuit Interrupter protected outlet.
- AC 120V 30A Twist Lock Outlet (L5-30R): For higher power applications.
- AC 120/240V 30A Outlet (L14-30R): For 120V or 240V applications.
- AC 120/240V 50A Outlet (14-50R): For high-power 50 amp applications.
- DC 12V Outlet (9A): For charging 12V batteries.
- DC 5V USB Ports: For charging USB devices.
- Battery Charger Inlet: For connecting the included battery charger.
- Ground Terminal (GND): For grounding the generator.
- Gas Valve: Controls gasoline flow.
- LPG Inlet: Connection point for propane hose.

Figure 3.2: LCD Multi-Meter displaying hours, voltage, load, and fuel levels.

Figure 3.3: ATS Outlet for connecting to a home's electrical panel.
4. Setup
4.1. Unpacking and Assembly
- Carefully remove the generator and all components from the packaging.
- Attach the wheels and support feet as per the included assembly guide.
4.2. Adding Engine Oil
- Place the generator on a level surface.
- Remove the oil fill cap/dipstick.
- Using the provided oil funnel, slowly add the recommended engine oil (SAE 10W-30) until it reaches the upper mark on the dipstick. Do not overfill.
- Securely replace the oil fill cap/dipstick.
4.3. Adding Fuel (Gasoline)
- Ensure the generator is turned off and cool.
- Open the fuel tank cap.
- Carefully pour fresh, unleaded gasoline (minimum 87 octane) into the fuel tank. Do not fill above the red indicator.
- Securely close the fuel tank cap.
4.4. Connecting Propane (LPG)
- Ensure the generator is turned off.
- Connect one end of the provided propane hose to the LPG inlet on the generator.
- Connect the other end of the hose to a standard propane tank.
- Tighten all connections securely to prevent leaks.
4.5. Charging the Battery
- Connect the included battery charger to the battery charger inlet on the control panel.
- Plug the charger into a standard 120V AC outlet.
- Allow the battery to charge fully before attempting to use the electric start feature.
5. Operation
5.1. Starting the Generator
The generator can be started using either the push-button start or the remote start feature.
5.1.1. Push-Button Start
- Ensure the generator is on a level surface and all safety checks are complete.
- Select the desired fuel type (Gasoline or LPG) using the Fuel Switch.
- Turn the Power Switch to the 'START' position.
- Press and hold the Push-Button Start until the engine starts.
- Once started, release the button and turn the Power Switch to the 'RUN' position.
5.1.2. Remote Start
- Ensure the generator is on a level surface and all safety checks are complete.
- Select the desired fuel type (Gasoline or LPG) using the Fuel Switch.
- Ensure the Power Switch is in the 'RUN' position.
- Press the 'START' button on the remote control.
- The generator will attempt to start. If it does not start on the first attempt, wait a few seconds and try again.

Figure 5.1: Remote start feature for convenient operation.
5.2. Fuel Selection
The AIVOLT generator is a dual-fuel unit, capable of running on either gasoline or propane. You can switch between fuel types even while the generator is running.

Figure 5.2: Fuel switch for selecting between gasoline and propane.
- To switch from gasoline to propane: Ensure propane tank is connected and open. Move the Fuel Switch from 'FUEL ON' to 'LPG INLET'.
- To switch from propane to gasoline: Ensure gasoline tank is filled. Move the Fuel Switch from 'LPG INLET' to 'FUEL ON'.
5.3. Eco Mode
Engage the Eco Mode switch to optimize fuel consumption and reduce noise during lighter loads. The engine RPM will adjust automatically based on the power demand.
5.4. Connecting Appliances
- Ensure the generator is running stably before connecting any appliances.
- Plug your appliances into the appropriate outlets on the control panel.
- Do not exceed the rated wattage of the generator or individual outlets.
5.5. Parallel Operation
For increased power output, two AIVOLT 11250 Watt Inverter Generators can be connected in parallel using a separate parallel kit (sold separately). Refer to the parallel kit's instruction manual for detailed connection procedures.

Figure 5.3: Illustrates two generators connected for parallel operation.
6. Maintenance
Regular maintenance is crucial for the longevity and optimal performance of your generator.
6.1. Engine Oil Change
- Change the engine oil after the first 20 hours of operation, and then every 100 hours or annually, whichever comes first.
- Drain the old oil when the engine is warm.
- Refill with the recommended SAE 10W-30 oil.
6.2. Air Filter Cleaning
- Inspect the air filter every 50 hours or monthly.
- Clean or replace if dirty.
6.3. Spark Plug Inspection
- Inspect the spark plug every 100 hours or annually.
- Clean or replace if necessary.
6.4. Storage
- For long-term storage, drain the fuel tank and carburetor of gasoline, or run the engine until it runs out of fuel.
- Disconnect the propane tank.
- Store the generator in a clean, dry, and well-ventilated area.
7. Troubleshooting
This section provides solutions to common operational issues. For problems not listed here, contact customer support.
| Problem | Possible Cause | Solution |
|---|---|---|
| Engine does not start | No fuel (gasoline or propane) Low engine oil Spark plug issue Battery discharged (for electric start) | Add fuel Add engine oil Inspect/replace spark plug Charge battery |
| No power output | Circuit breaker tripped Overload Loose connections | Reset circuit breaker Reduce load Check and secure connections |
| Engine runs, then stops | Low engine oil CO sensor activated Overload Lack of fuel | Add engine oil Move generator to well-ventilated area Reduce load Add fuel |
| Excessive noise | Generator under heavy load Loose components | Engage Eco Mode for lighter loads Check for loose parts and tighten |
8. Specifications
Key technical specifications for the AIVOLT 11250 Watt Dual Fuel Inverter Generator.
| Feature | Specification |
|---|---|
| Brand | AIVOLT |
| Model Name | VS12000411 |
| Starting Wattage (Gasoline) | 11250 Watts |
| Running Wattage (Gasoline) | 9000 Watts |
| Starting Wattage (Propane) | 10570 Watts |
| Running Wattage (Propane) | 8540 Watts |
| Fuel Type | Dual Fuel (Gasoline/Propane) |
| Engine Type | 4 Stroke, 459cc |
| Fuel Tank Capacity | 7.1 Gallons (27 Liters) |
| Runtime (25% Load) | Up to 19 hours |
| Voltage | 120 Volts (selectable 120V/240V) |
| Ignition System | Electric Start |
| Product Dimensions (L x W x H) | 28.43" x 26.38" x 29.65" |
| Noise Level | 60 dBA (at 25% load) |
| Total Power Outlets | 3 (various types) |

Figure 8.1: Generator dimensions for planning placement and storage.

Figure 8.2: Noise level comparison, highlighting the generator's quiet operation.
9. Warranty and Support
AIVOLT products are manufactured to high-quality standards. For warranty information, technical support, or to order replacement parts, please refer to the warranty card included with your product or visit the official AIVOLT website. Keep your purchase receipt as proof of purchase for warranty claims.
For customer service inquiries, please contact AIVOLT support through their official channels.