Goodman GLXS3BN3610CHPTA4230C3

Goodman 3 Ton 13.4 SEER2 R-32 AC System with Horizontal Coil User Manual

Models: GLXS3BN3610 Condenser & CHPTA4230C3 Coil

1. Introduction

This manual provides essential information for the safe and efficient operation of your Goodman 3 Ton 13.4 SEER2 R-32 AC Only System, comprising the GLXS3BN3610 Air Conditioner Condenser and the CHPTA4230C3 Horizontal Coil. This system is designed to provide efficient cooling for your home. Please read this manual thoroughly before installation or operation.

2. Important Safety Information

WARNING: Installation and servicing of this equipment can be hazardous due to mechanical and electrical components. Only trained and qualified personnel should install, repair, or service HVAC equipment. Improper installation, adjustment, alteration, service, or maintenance can cause property damage, personal injury, or death.

This system utilizes R-32 refrigerant, which is mildly flammable. Proper handling and installation procedures are critical to ensure safety. A certified HVAC technician must perform all installation and service work.

3. System Components

Your Goodman AC system includes the following primary components:

Note: This is a partial system. A furnace or modular blower is required to complete the system and provide air circulation and heating capabilities (if applicable).

Goodman GLXS3BN3610 Condenser and CHPTA4230C3 Horizontal Coil

Figure 1: Goodman GLXS3BN3610 Condenser and CHPTA4230C3 Horizontal Coil

Goodman GLXS3BN3610 Condenser

Figure 2: Goodman GLXS3BN3610 Condenser Unit

Goodman CHPTA4230C3 Horizontal Coil

Figure 3: Goodman CHPTA4230C3 Horizontal Coil Unit

4. Setup & Installation

Installation of this HVAC system must be performed by a qualified, licensed HVAC professional. Incorrect installation can lead to system malfunction, safety hazards, and void the warranty.

4.1. System Compatibility

This system is designed to be paired with a compatible furnace or modular blower. Ensure that the indoor coil (CHPTA4230C3) is correctly matched with your furnace's airflow configuration (horizontal for this coil).

Video 1: This video explains the importance of matching your condenser and coil for optimal system performance.

4.2. SEER2 Regulations

As of January 1, 2023, new SEER2 (Seasonal Energy Efficiency Ratio 2) regulations are in effect. This Goodman system has a 13.4 SEER2 rating. Please note that federal regulations specify minimum SEER2 ratings based on geographic region. This system does not comply with federal regulations for installation in the following states: AL, AR, AZ, CA, DE, FL, GA, KY, LA, MD, MS, NC, NM, NV, OK, SC, TN, TX, and VA.

Energy Guide Label for Goodman GLXS3BN3610A

Figure 4: Energy Guide label showing 13.40 SEER2 rating for the Goodman GLXS3BN3610A model.

US Map showing North and South HVAC regions

Figure 5: US Map indicating the North Region (blue) where 13.4 SEER2 is acceptable, and other regions (orange and green) with different minimum requirements.

Video 2: This video provides an overview of the SEER2 regulations that came into effect on January 1, 2023.

4.3. R-32 Refrigerant

This system uses R-32 refrigerant. R-32 is a more energy-efficient refrigerant with a lower global warming impact compared to older refrigerants. It is mildly flammable, requiring specific installation and servicing protocols. If this system is paired with a furnace, an R-32 leak detection system is required to ensure safe operation by turning off the furnace burner in case of a refrigerant leak.

Video 3: This video explains the new refrigerant regulations and the properties of R-32.

Video 4: This video clarifies facts versus fiction regarding R-32 refrigerant.

5. Operating Instructions

Once installed by a qualified technician, your Goodman AC system will operate to provide cooling. The system is controlled via your home's thermostat. Set your desired temperature, and the system will cycle on and off to maintain it.

Video 5: This video explains different types of HVAC systems, including split systems like this one, and how they operate.

6. Maintenance

Regular maintenance is crucial for the longevity and efficiency of your AC system. It is recommended to have your system inspected and serviced by a qualified HVAC technician annually.

7. Troubleshooting

If you experience issues with your system, consider the following basic checks before contacting a service technician:

For any issues beyond basic troubleshooting, contact a qualified HVAC service technician. Do not attempt complex repairs yourself.

8. Specifications

FeatureSpecification
BrandGoodman
Model InfoGLXS3BN3610CHPTA4230C3
Condenser ModelGLXS3BN3610
Coil ModelCHPTA4230C3
Capacity3 Tons
SEER2 Rating13.4
Refrigerant TypeR-32
Installation TypeSplit System
Coil OrientationHorizontal
Item Weight246 pounds (combined)
Special FeatureFast Cooling

9. Warranty Information

This Goodman system comes with a 10-year parts limited warranty. To qualify for the full warranty, the system must be installed by a qualified installer and registered online within 60 days of installation. Online registration is not required in California.

For complete warranty details and terms, please refer to the official Goodman warranty documentation or contact customer support.

Goodman 10 Year Limited Warranty Shield

Figure 6: Goodman 10-Year Limited Warranty Shield.

10. Customer Support

For technical assistance, warranty claims, or any questions regarding your Goodman HVAC system, please contact Superior Home Supplies customer support. Their contact information can typically be found on your purchase receipt or their official website.

Related Documents - GLXS3BN3610CHPTA4230C3

Preview Goodman GPG13 Packaged Gas/Electric Unit Product Specifications
Detailed product specifications for the Goodman GPG13 series of single-phase, self-contained packaged gas/electric units, covering features, cabinet details, nomenclature, specifications, dimensions, wiring diagrams, and accessories.
Preview Horizontal Two-Way Coil Installation Instructions | Goodman HVAC
Comprehensive installation guide for Goodman horizontal two-way HVAC coils. Covers essential safety warnings, pre-installation checks, application details, duct flange attachment, condensate drain piping, refrigerant line procedures, flowrator setup, coil cleaning, and a start-up checklist. Includes model IO-285M information.
Preview Horizontal Two-Way Coil Installation Instructions | Goodman, Daikin, Amana HVAC
Comprehensive installation guide for horizontal two-way evaporator coils manufactured by Goodman Manufacturing Company, L.P., for use with Goodman, Daikin, and Amana HVAC systems. Covers essential safety precautions, pre-installation checks, application details, duct flange attachment, condensate drain piping, refrigerant line installation, flowrator adjustments, and indoor coil cleaning procedures. Includes troubleshooting tips and contact information.
Preview Goodman GPCH3 Packaged Air Conditioner Specifications and Features
Comprehensive guide to the Goodman GPCH3 series packaged air conditioners, covering standard and cabinet features, nomenclature, detailed product specifications, expanded cooling and airflow data, electrical information for heat kits, dimensions, wiring diagrams, and available accessories. Designed for efficiency and durability, these units are available in 2 to 5 tons with 13.4 SEER2 ratings.
Preview Goodman Horizontal Two-Way Coil Installation Instructions (IO-285G)
Comprehensive installation guide for Goodman Horizontal Two-Way Coils (Model IO-285G). Includes essential safety warnings, pre-installation checks, application details, ductwork and condensate drain setup, refrigerant line procedures, and special flowrator instructions for HVAC technicians.
Preview Goodman Horizontal Two-Way Coil Installation Instructions
Detailed installation instructions for Goodman Horizontal Two-Way Coils (P/N: IO-285B), covering safety warnings, shipping inspection, codes and regulations, replacement parts, pre-installation steps, application information, duct flange attachment, condensate drain piping, and refrigerant line procedures. Includes diagrams described in text.