1. Introduction
This manual provides essential information for the safe and efficient operation, installation, and maintenance of your ACiQ 4 Ton 15.5 SEER2 High Efficiency Central Air Conditioner System. Please read this manual thoroughly before installation and use, and retain it for future reference. Proper installation and maintenance are crucial for optimal performance and longevity of the unit.
2. Safety Information
Important Safety Instructions:
- Installation and servicing must be performed by a qualified HVAC technician. Improper installation can result in electric shock, fire, or water leakage.
- Ensure the unit is properly grounded to prevent electrical shock.
- Turn off all power to the unit before performing any maintenance or servicing.
- Do not block the air intake or outlet of the outdoor or indoor units.
- Use only specified refrigerants (R410A) and follow all environmental regulations.
- Keep children and pets away from the outdoor unit during operation.
3. Product Overview and Features
The ACiQ 4 Ton 15.5 SEER2 Central Air Conditioner System is designed for high-efficiency cooling, featuring inverter technology for precise temperature control and energy savings. This system includes an outdoor condenser, an indoor multi-positional evaporator cased coil, and a comprehensive installation kit.
Key Features:
- Inverter AC Technology: Adjusts compressor speed for optimal temperature control, reduced energy consumption, and quieter operation.
- Multi-Positional Cased Coil: Factory-integrated TXV ensures efficient operation and flexibility in various installation configurations, enhancing HVAC performance.
- High Efficiency: 15.5 SEER2 rating for significant energy savings.
- Durable Construction: Features a Gold Fin condenser coil for enhanced corrosion resistance and longevity.
- Quiet Operation: Engineered for ultra-quiet performance, with a noise level of 56 dB.
- Smart Sensors: Integrated smart sensors for intelligent operation and performance monitoring.
- All-Climate Performance: Designed to operate effectively across a wide range of outdoor temperatures.
- Leak Detection: System includes alerts for refrigerant leaks to prevent hazards.
Included Components:
The complete system includes the following components:
- Outdoor Condenser Unit
- Indoor Multi-Positional Evaporator Cased Coil
- Smart WiFi Thermostat
- 50' Insulated Line Set (3/8" LL x 3/4" SL x 3/8")
- 1/2" x 6' 10 Gauge Electrical Whip
- 60A Non-fused Disconnect Switch
- Controls Surge Protector
- CPS Charging Adapter
- Wall Sleeve
- Wall Mount Bracket
- User Manual (this document)

Figure 3.1: Overview of the ACiQ 4 Ton Central Air Conditioner System, showing the outdoor condenser, indoor evaporator coil, smart thermostat, and various installation kit components.

Figure 3.2: Detailed view of the ACiQ Split System Installation Kit, including the insulated line set, electrical whip, disconnect switch, surge protector, and smart thermostat.

Figure 3.3: Close-up of the ACiQ outdoor condenser unit, highlighting its robust construction and fan design.
4. Setup and Installation
Professional Installation Required: Due to the complexity of HVAC systems, installation and initial setup of this ACiQ unit must be performed by a certified and qualified HVAC technician. Attempting to install the system without proper training and tools can lead to property damage, personal injury, and void the product warranty.
The installation process typically involves:
- Site Selection: Choosing appropriate locations for the outdoor condenser and indoor evaporator coil, ensuring adequate airflow and drainage.
- Mounting Units: Securely mounting the outdoor condenser (using the provided wall mount bracket if applicable) and positioning the indoor evaporator coil.
- Refrigerant Line Connection: Connecting the insulated line set between the indoor and outdoor units, ensuring proper brazing and leak testing.
- Electrical Wiring: Connecting the electrical whip, disconnect switch, and surge protector according to local electrical codes and the unit's wiring diagram.
- Condensate Drainage: Installing proper drainage for the indoor evaporator coil.
- Vacuum and Charging: Evacuating the refrigerant lines and charging the system with the correct amount of R410A refrigerant.
- Thermostat Installation: Wiring and configuring the Smart WiFi Thermostat.
- System Test: Performing a comprehensive test run to ensure all components are functioning correctly and efficiently.
Refer to the detailed installation guide provided to your HVAC technician for specific instructions and diagrams.
5. Operating Instructions
Your ACiQ system is controlled by the included Smart WiFi Thermostat. Once installed and configured by a professional, operating the system is straightforward.
Smart WiFi Thermostat Operation:
The thermostat allows you to control various aspects of your air conditioning system. Consult the separate thermostat user manual for detailed instructions on its specific features, including:
- Mode Selection: Switch between cooling, fan-only, or off modes.
- Temperature Setting: Adjust the desired indoor temperature.
- Scheduling: Program daily or weekly temperature schedules for energy efficiency.
- Fan Speed Control: Adjust fan speed (if applicable).
- Connectivity: Connect to your home WiFi network for remote control via a smartphone app and integration with smart home systems (e.g., Alexa, Google Home, SmartThings, IFTTT).
- Humidity Monitoring: View indoor humidity levels.
- System Status: Monitor current indoor temperature, cooling set point, and system operational status.

Figure 5.1: Diagram illustrating the features and interface of the Smart WiFi Thermostat, including mode, humidity, temperature settings, and connectivity options.
For optimal performance, set the thermostat to a comfortable temperature and avoid frequent, drastic changes. The inverter technology will maintain the set temperature efficiently.
6. Maintenance
Regular maintenance is essential to ensure the longevity, efficiency, and optimal performance of your ACiQ air conditioning system. Some maintenance tasks can be performed by the homeowner, while others require a qualified technician.
User Maintenance (Monthly/Quarterly):
- Clean or Replace Air Filters: Check and clean or replace the air filters in your indoor unit (or furnace/air handler, if applicable) monthly, or more frequently if the system is used heavily or in dusty environments. The system uses washable, reusable mesh filters.
- Clear Outdoor Unit: Ensure the outdoor condenser unit is free from debris, leaves, grass clippings, and other obstructions that could block airflow. Keep vegetation trimmed around the unit.
- Check Condensate Drain: Periodically check the condensate drain line for blockages. A clogged drain can cause water overflow.
Professional Maintenance (Annually):
It is highly recommended to schedule annual maintenance with a qualified HVAC technician. This typically includes:
- Cleaning of condenser and evaporator coils.
- Checking refrigerant levels and pressure.
- Inspecting electrical connections and components.
- Lubricating moving parts (if applicable).
- Checking thermostat calibration.
- Inspecting ductwork for leaks.
- Verifying proper system operation and performance.
7. Troubleshooting
Before contacting a service technician, review the following common issues and their potential solutions. For complex problems, always consult a qualified HVAC professional.
| Problem | Possible Cause | Solution |
|---|---|---|
| System Not Cooling |
|
|
| Weak Airflow |
|
|
| Unusual Noises |
|
|
| Water Leakage (Indoor Unit) |
|
|
If the problem persists after attempting these solutions, or if you encounter any other issues, contact a qualified HVAC service technician.
8. Specifications
Detailed technical specifications for the ACiQ 4 Ton 15.5 SEER2 Central Air Conditioner System:
| Specification | Value |
|---|---|
| Brand | ACiQ |
| Model Numbers | ACiQ-48-AC / ACIQ-60-ACL / IKIC51 |
| Capacity | 4 Tons (48,000 BTU/h) |
| Efficiency (SEER2) | 15.5 SEER2 |
| Refrigerant Type | R410A |
| Voltage | 230 Volts |
| Wattage | 4000 watts |
| Noise Level | 56 dB |
| Outdoor Unit Dimensions (D x W x H) | 16.14" x 37.24" x 52.48" |
| Indoor Coil Dimensions (W x D x H) | 24.49" x 20.98" x 27.99" (622 x 533 x 711 mm) |
| Installation Type | Split System |
| Form Factor | Central Split System |
| Filter Type | Washable, Reusable Mesh Filter |
| Floor Area Coverage | Approximately 2400 Square Feet |
| Special Features | Inverter Unit, Smart Sensors, Gold Fin Coil, Ultra-Quiet, All-Climate Performance |

Figure 8.1: Dimensional measurements for the ACiQ outdoor condenser unit and the indoor evaporator coil.

Figure 8.2: Detailed specifications for the ACiQ evaporator coil, including air flow, pressure, dehumidification, and dimensions.

Figure 8.3: AHRI (Air-Conditioning, Heating, and Refrigeration Institute) certification details and EnergyGuide label, confirming the system's efficiency rating.
9. Warranty and Support
Warranty Terms: The ACiQ system comes with a 7-year parts warranty and a 12-year compressor warranty. This warranty is valid when the unit is installed by a qualified technician and registered online with the manufacturer. Please ensure your installer registers the product to activate the full warranty coverage.
Customer Support: For technical assistance, warranty claims, or to locate a certified service provider, please refer to the contact information provided on the ACiQ official website or the documentation included with your purchase. You can also visit the ACiQ Store on Amazon for more information.