1. Product Overview
This manual provides essential information for the Goodman 2 Ton 14.3 SEER2 AC Only System, comprising the GLXS4BA2410 condenser and CAPTA2422B3 vertical coil. This system is designed to provide efficient cooling for your home. Please note that this is not a complete system and requires a separate furnace or modular blower for full functionality. Proper installation by a qualified HVAC professional is crucial for safe and optimal performance.

Image 1: Goodman GLXS4BA2410 Condenser and CAPTA2422B3 Vertical Coil AC System. This image shows both the outdoor condenser unit and the indoor vertical coil.
2. Safety Information
WARNING: Installation and servicing of air conditioning equipment can be hazardous due to system pressure, electrical components, and sharp edges. Only trained and qualified personnel should install, repair, or service this equipment.
- Always disconnect power before servicing.
- This system uses R-32 refrigerant, which is mildly flammable. An R-32 leak detection system is required for safe operation, particularly when used with a furnace.
- Ensure proper ventilation during installation and servicing.
- Wear appropriate personal protective equipment (PPE) including gloves and eye protection.
- Refer to all local and national safety codes and regulations.
3. Product Components
3.1. GLXS4BA2410 Air Conditioner Condenser

Image 2: Goodman GLXS4BA2410 Air Conditioner Condenser. This is the outdoor unit responsible for releasing heat from your home.
The GLXS4BA2410 is a 2 Ton, 14.3 SEER2 single-stage AC condenser. It features service valves, gauge ports, and inspection points for ease of maintenance. The unit is pre-charged for 15 feet of tubing and includes a factory-installed filter drier for cleaner operation.
3.2. CAPTA2422B3 Vertical Coil

Image 3: Goodman CAPTA2422B3 Vertical Coil. This indoor coil works with your furnace or air handler to cool the air.
The CAPTA2422B3 is a vertical coil designed for optimal airflow and heat transfer. Constructed with corrosion-resistant aluminum and featuring grooved tubing, it undergoes rigorous helium pressure tests to ensure quality and durability. This coil is intended to be paired with a furnace or modular blower.
4. Installation Guidelines
Installation of this Goodman AC system must be performed by a qualified HVAC technician. Incorrect installation can lead to system malfunction, safety hazards, and void the product warranty.
- Ensure the GLXS4BA2410 condenser and CAPTA2422B3 coil are compatible with your existing or new furnace/blower.
- Proper sizing of the system to your home's cooling load is essential for efficiency and comfort.
- The R-32 refrigerant requires specific tools and procedures for handling and charging.
- An R-32 leak detection system must be installed, especially when the system is paired with a furnace, to ensure safety.
- Follow all manufacturer's instructions and local building codes.
4.1. Condenser and Coil Combination
For detailed information regarding the combination of condenser and coil, please watch the following video:
Video 1: Condenser with Coil Combination. This video explains important considerations when pairing a condenser with a coil.
4.2. Understanding Your System Type
To ensure proper installation and compatibility, it is important to understand the type of HVAC system you have. The following video provides an overview of different system types:
Video 2: What type of system do you have? This video helps identify common HVAC system configurations.
5. Operating Instructions
Once installed by a qualified technician, your Goodman AC system will operate automatically based on your thermostat settings. For optimal performance:
- Set your thermostat to your desired cooling temperature.
- Avoid frequently adjusting the thermostat, as this can reduce efficiency.
- Ensure all vents are open and unobstructed for proper airflow.
- Keep windows and doors closed while the system is operating.
6. Maintenance
Regular maintenance is essential for the longevity and efficiency of your AC system. It is recommended to have your system inspected and serviced annually by a qualified HVAC technician.
- Filter Replacement: Check and replace your air filter monthly, or as recommended by your technician, to ensure proper airflow and indoor air quality.
- Outdoor Unit Cleaning: Keep the area around the outdoor condenser unit clear of debris, leaves, and vegetation to prevent airflow obstruction.
- Coil Cleaning: The indoor and outdoor coils should be professionally cleaned periodically to maintain heat transfer efficiency.
- Drain Line Check: Ensure the condensate drain line is clear and free of blockages to prevent water overflow.
7. Troubleshooting
If you experience issues with your AC system, consider the following basic troubleshooting steps before contacting a technician:
- No Cooling: Check your thermostat settings to ensure it's set to 'Cool' and the temperature is below the current room temperature. Verify that the circuit breaker for the HVAC system has not tripped.
- Weak Airflow: Check and replace the air filter if it's dirty. Ensure all supply and return vents are open.
- Unusual Noises: Strange noises can indicate a mechanical issue. Turn off the system and contact a qualified technician.
- System Not Turning On: Check the thermostat for power and correct settings. Inspect the outdoor unit for any visible damage or obstructions.
For any persistent issues or complex problems, always contact a qualified HVAC professional.
8. Specifications
| Feature | Detail |
|---|---|
| Brand | Goodman |
| Model Number | GLXS4BA2410CAPTA2422B3 |
| Capacity | 2 Tons |
| Cooling Power | 24000 British Thermal Units |
| Seasonal Energy Efficiency Ratio (SEER2) | 14.3 |
| Refrigerant Type | R-32 |
| Coil Type | Vertical |
| Color | Architectural Gray |
| Item Weight | 197 pounds |
| AHRI Certified | Yes, Certificate Number 215213886 |
8.1. Energy Efficiency Rating

Image 4: EnergyGuide Label. This label indicates the efficiency rating of the GLXS4BA2410 condenser.
8.2. SEER2 Regulations
The Seasonal Energy Efficiency Ratio 2 (SEER2) is a new standard for measuring the energy efficiency of air conditioning systems. The following video provides important information about these regulations:
Video 3: SEER2 Regulations - 01. This video explains the updated energy efficiency standards for HVAC equipment.
8.3. R-32 Refrigerant Information
This system utilizes R-32 refrigerant. It is important to understand the characteristics and regulations surrounding this refrigerant. The following videos offer insights into R-32:
Video 4: R-32 Fact vs Fiction. This video clarifies common misconceptions about R-32 refrigerant.
Video 5: Info about the refrigerant regulations. This video provides details on current refrigerant regulations affecting HVAC systems.
9. Warranty Information
This Goodman AC system comes with a 10-year parts limited warranty. To qualify for the full warranty, the system must be installed by a qualified installer and registered online within 60 days of installation. Online registration is not required in California.

Image 5: 10 Year Limited Warranty Shield. This emblem signifies the product's warranty coverage.
For complete warranty details and terms, please contact Goodman customer support or your qualified installer.
10. Support & Contact
For technical assistance, service, or warranty inquiries, please contact your installing HVAC professional. They are best equipped to diagnose and resolve any issues with your Goodman AC system.
You may also visit the official Goodman website for additional product information and support resources.