Introduction
The iHealth Dual-Channel TENS Unit Muscle Stimulator is designed to provide customizable pain relief for various muscle soreness and discomfort. This device utilizes Transcutaneous Electrical Nerve Stimulation (TENS) technology to help manage pain caused by physical activities, prolonged sitting, household chores, and is suitable for seniors and post-surgery recovery. It offers independent control over two channels, allowing for personalized treatment across different body areas.
Important Safety Note: The TENS unit should not be used on open wounds.
What's in the Box
Upon unboxing your iHealth Dual-Channel TENS Unit, please ensure all components listed below are present:
- 1 x Main Unit
- 1 x Storage Bag
- 2 x Pad Holders
- 2 x Electrode Cords (Model: 23507-3.8-1201)
- 2 x Rectangle Electrode Pads (Model: EP5010036N01)
- 8 x Square Electrode Pads (Model: EP505036N01)
- 4 x AAA Batteries
- 1 x Instruction Manual
- 1 x Quick Start Guide

Image: All components included in the iHealth Dual-Channel TENS Unit package.
Setup
- Insert Batteries: Open the battery compartment on the back of the main unit. Insert 4 AAA batteries, ensuring correct polarity. Close the compartment securely.
- Connect Electrode Cords: Plug the electrode cords into the A and B ports located at the top of the main unit.
- Attach Electrode Pads: Snap the electrode pads onto the ends of the electrode cords. Ensure a secure connection.
- Prepare Skin: Clean and dry the skin area where you intend to place the electrode pads. Avoid placing pads on broken skin, open wounds, or sensitive areas.
- Apply Electrode Pads: Remove the protective film from the electrode pads and firmly press them onto the desired treatment areas on your body. Ensure good contact with the skin for optimal performance.

Image: The iHealth TENS unit in use, highlighting its features and portability.

Image: Illustration of the A/B Dual Channels feature, allowing independent control of two treatment areas.
Operating Instructions
- Power On: Press and hold the power button (U) to turn on the device. The large backlit LCD display will illuminate.
- Select Mode: Use the mode button to cycle through the 6 available treatment modes: Composite, Knock, Press, Slap, Acupuncture, and Muscle Relaxation. Each mode has 4 variations.
- Adjust Intensity: Use the up (^) and down (v) arrow buttons to adjust the intensity level. There are 15 intensity levels available. Start with a low intensity and gradually increase until you feel a comfortable, stimulating sensation.
- Set Timer: The device features an adjustable treatment timer from 0 to 30 minutes. Use the timer controls to set your desired session duration.
- Dual-Channel Control: The A/B button allows you to switch between and independently control the intensity and mode for each channel (A and B). This is useful for treating two different areas simultaneously with different settings.
- Power Off: Press and hold the power button (U) to turn off the device after your session.

Image: The iHealth TENS unit provides safe, non-invasive pain relief for various body parts.
Maintenance
- Cleaning Electrode Pads: After each use, gently wipe the adhesive side of the electrode pads with a damp cloth to remove any residue. Allow them to air dry completely.
- Storing Electrode Pads: To extend the lifespan of your electrode pads, place them back onto the provided pad holders after cleaning and drying. This protects the adhesive from dust and debris.
- Battery Replacement: When the battery indicator on the display shows low power, replace all 4 AAA batteries with new ones to ensure consistent performance.
- Device Storage: Store the main unit, electrode cords, and pads in the convenient storage bag provided when not in use. Keep the device in a cool, dry place away from direct sunlight and extreme temperatures.

Image: Detailed view of the reusable electrode pad construction.

Image: Proper storage of electrode pads and the TENS unit for longevity and portability.
Troubleshooting
If you encounter any issues with your iHealth Dual-Channel TENS Unit, please refer to the following common troubleshooting steps:
- No Sensation or Weak Sensation:
- Ensure the electrode pads are firmly attached to your skin and the cords are securely plugged into the device.
- Increase the intensity level gradually using the up arrow button.
- Check the battery level on the display. Replace batteries if low.
- The electrode pads may have lost their adhesiveness. Clean them or replace them if necessary.
- Electrode Detachment Warning: The device features an electrode detachment warning. If a flashing indicator appears for Channel A or B, it means there is an issue with the electrode attachment. This could be due to loose or improper pad placement, insufficient contact with the skin surface, or the electrode pad exceeding its recommended usage life. Also, check if the wire-to-electrode connection needs adjustment or if the cable is not fully inserted into the device.

Image: Understanding the Electrode Detachment Warning system.
Specifications
| Feature | Specification |
|---|---|
| Model | AD-2126 |
| Output Pulse Frequency | 0-100Hz |
| Output Pulse Width | 20-100μs |
| Batteries | 4 x 1.5V AAA Size |
| Environmental Temperature for Operation | 41°F - 104°F (5°C - 40°C) |
| Environmental Humidity for Operation | ≤80%RH |
| Environmental Temperature for Storage and Transport | -4°F - 131°F (-20°C - 55°C) |
| Environmental Humidity for Storage and Transport | ≤90%RH |
| Environmental Pressure | 80kPa-105kPa |
Warranty and Support
The iHealth Dual-Channel TENS Unit comes with a 1-Year Limited Warranty, ensuring reliability and quality assurance. It is also eligible for FSA/HSA, providing ease of access for effective pain management.
For any questions or assistance, iHealth offers US-Based Customer Support. Our dedicated team in the San Francisco Bay Area provides real-time assistance for all your needs. You can find contact information in the included instruction manual or on the official iHealth website.
Legal Disclaimer
Statements regarding dietary supplements have not been evaluated by the FDA and are not intended to diagnose, treat, cure, or prevent any disease or health condition.