Akicon B0DDTFV2VK

Akicon Ultra Quiet Bathroom Exhaust Fan with Light

Model: B0DDTFV2VK

Introduction

This manual provides detailed instructions for the installation, operation, and maintenance of your Akicon Ultra Quiet Bathroom Exhaust Fan with Light. This unit is designed to effectively remove moisture and odors from your bathroom, enhancing comfort and air quality. It features an integrated light and a humidity sensor switch for automated operation.

Akicon bathroom exhaust fan with light, highlighting ultra-quiet operation, energy saving, strong airflow, and long lifetime.

Image: Akicon bathroom exhaust fan with light, highlighting ultra-quiet operation, energy saving, strong airflow, and long lifetime.

Safety Information

WARNING: To reduce the risk of fire, electric shock, or injury to persons, observe the following:

  • Always disconnect power at the service panel before installing or servicing this unit.
  • Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction codes and standards.
  • Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer.
  • Do not use this fan with any solid-state speed control device unless specifically approved by the manufacturer.
  • This product is designed for general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors.

Package Contents

Verify that all components are present before beginning installation:

  • Exhaust Fan Unit with Light
  • Frosted Glass Cover
  • Humidity Sensor and Timer Switch
  • Installation Hardware (screws, wire connectors)
  • Instruction Manual

Specifications

BrandAkicon
ModelB0DDTFV2VK
ColorOil Rubbed Bronze
Airflow80 CFM
Sones2.0 Sones
Housing Dimensions8-1/2" x 8-1/2" x 5-3/4" (L x W x H)
Light Cover Diameter13"
Duct Size4 inch
Power SourceAC
Room TypeBathroom
CertificationcUL, HVI Listed

Installation

This fan is designed for easy installation or replacement of existing units, even without attic access. Ensure the ceiling opening size is 9"x9" for proper fit.

1. Verify Dimensions

Before purchasing and installation, confirm the housing and light cover dimensions to ensure compatibility with your space.

Diagram showing dimensions for Akicon bathroom exhaust fan housing, duct, and light cover.

Image: Diagram showing dimensions for Akicon bathroom exhaust fan housing, duct, and light cover. Housing Dimensions: 8-1/2" x 8-1/2" x 5-3/4". Light Cover Diameter: 13". Ceiling Opening Size: 9"x9".

Dimensions of the Akicon humidity sensor and timer switch.

Image: Dimensions of the Akicon humidity sensor and timer switch. Switch dimensions are approximately 3-1/4" W x 4-1/8" H x 1-1/10" D.

2. Wiring Instructions

CAUTION: Cut off the power before installation. A neutral wire is needed to power the switch.

Follow the wiring diagram carefully. Connect the LINE, Night Lamp (Out1), Lighting LED (Out2), FAN (Out3), Neutral Wire, and Ground Wire as indicated. Ensure all connections are secure and comply with local electrical codes.

Wiring diagram for the Akicon humidity switch and junction box, showing connections for line, night lamp, lighting LED, fan, neutral wire, and ground wire.

Image: Wiring diagram for the Akicon humidity switch and junction box. Shows connections for Line (black), Out1 Night lamp (red), Out2 Lighting LED (red), Out3 FAN (red), Neutral Wire (white), and Ground Wire (green). If the junction box is plastic, follow the green dashed line for ground; if metal, follow the green solid line.

Operating Instructions

The Akicon exhaust fan features a humidity sensor and timer switch for flexible operation.

Humidity Sensor and Timer Switch Functions

  • Humidity Sensor: Detects humidity levels in the room.
  • Timer: Allows setting the fan to turn off after a specific duration.
  • Fan Switch: Manually turns the fan ON or OFF.
  • LED Light Switch: Controls the main LED light. Pressing within 2 seconds can cycle through color temperatures.
  • Night Light Switch: Controls the night light function.
  • LED Indicator: Blue for fan, Green for light.
Close-up of the Akicon humidity sensor and timer switch, showing LED indicators, fan switch, LED light switch, and night light switch.

Image: Close-up of the Akicon humidity sensor and timer switch, showing LED indicators, fan switch, LED light switch, and night light switch. The switch has dials for humidity and time settings under a removable cover plate.

Operating Modes

The switch supports both automatic and manual operation modes:

  • Auto Mode: The fan automatically turns ON when humidity exceeds a preset level and turns OFF after it drops to normal (or after 5 minutes if humidity is below the set value).
  • Manual Mode: Pressing the fan button switches the fan operation state. If the fan is turned ON manually, it will switch to auto mode after a specified time. If turned OFF manually, it will switch to auto mode after 10 minutes.

The humidity sensor and timer feature 5 levels each to choose from: Humidity (90%, 80%, 70%, 60%, 50%) and Time (5, 15, 30, 45, 60 min).

Diagram explaining Auto Mode and Manual Mode operation for the Akicon humidity sensor switch, with energy efficiency rating.

Image: Diagram explaining Auto Mode and Manual Mode operation for the Akicon humidity sensor switch. Details how the fan operates based on humidity levels and manual overrides.

Maintenance

Regular maintenance ensures optimal performance and longevity of your exhaust fan.

Cleaning the Fan and Light Cover

  • WARNING: Disconnect power at the service panel before cleaning.
  • Remove the light cover by gently pulling it down.
  • Wipe the light cover with a soft, damp cloth. Do not use abrasive cleaners.
  • Carefully clean the fan blades and housing interior with a damp cloth or vacuum cleaner attachment. Avoid getting water into electrical components.
  • Ensure all parts are dry before reassembling the light cover and restoring power.

Troubleshooting

If you experience issues with your Akicon exhaust fan, refer to the following common problems and solutions:

ProblemPossible CauseSolution
Fan does not turn onNo power, loose wiring, faulty switchCheck circuit breaker. Verify wiring connections. Test switch functionality.
Light does not turn onLoose wiring, faulty light switch, bulb issue (if replaceable)Check wiring. Test light switch. If applicable, replace bulb.
Fan is noisyLoose mounting, debris in fan, motor issueEnsure fan is securely mounted. Clean fan blades. If noise persists, contact support.
Humidity sensor not respondingIncorrect sensitivity setting, sensor obstruction, faulty sensorAdjust humidity sensitivity setting. Ensure sensor is clear. If issue persists, contact support.

Warranty and Support

This Akicon exhaust fan comes with a 3-Year Limited Warranty. For warranty claims, technical assistance, or any questions regarding your product, please contact Akicon customer service.

You can typically find contact information on the Akicon official website or through your purchase platform.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.