1. Introduction
This user manual provides detailed instructions for the safe and effective operation of your Oklar Blood Pressure Monitor, Model C03-01. This device is designed for home use to measure systolic and diastolic blood pressure, as well as pulse rate, using the oscillometric method. It is intended for adults and features a large, easy-to-read display and memory functions for two users.
Please read this manual thoroughly before first use and keep it for future reference. For any medical concerns, consult with a healthcare professional.
2. Package Contents
Upon opening the package, please verify that all components listed below are present and undamaged:
- Oklar Blood Pressure Monitor Unit
- Adjustable Arm Cuff
- USB Charging Cable
- User Manual (this document)
- Storage Bag

Figure 2.1: All components included in the Oklar Blood Pressure Monitor package.
This image displays the Oklar Blood Pressure Monitor unit, the arm cuff, a USB charging cable, the user manual, and a black storage bag, laid out on a surface.
3. Setup and Preparation
3.1 Powering the Device
The Oklar Blood Pressure Monitor is powered by a built-in rechargeable battery. Before first use, ensure the device is fully charged.
- Connect the small end of the provided USB charging cable to the charging port on the side of the monitor.
- Connect the larger end of the USB cable to a standard USB power adapter (not included) or a computer USB port.
- The battery indicator on the display will show charging status. Charge until the indicator shows a full charge.
3.2 Attaching the Arm Cuff
Proper cuff attachment is crucial for accurate readings.
- Insert the air tube connector from the cuff firmly into the air jack on the side of the monitor.
- Ensure the connection is secure to prevent air leakage during measurement.
3.3 Initial Settings (Time/Date/User)
While the manual does not detail specific time/date settings, the device supports dual users (User A and User B). To switch between users or access settings, press the SET button. Follow the on-screen prompts to adjust any available settings.

Figure 3.1: Device buttons for setting, measurement, and memory.
This image highlights the three main buttons on the monitor: "SET" for device settings, "START/STOP" for taking measurements, and "MEM" for viewing history.
4. Operation
4.1 Preparing for Measurement
For accurate readings, follow these guidelines:
- Avoid eating, drinking alcohol, smoking, exercising, or bathing for 30 minutes before measurement.
- Rest for at least 5 minutes before taking a measurement.
- Sit upright with your back supported and feet flat on the floor. Do not cross your legs.
- Place your arm on a flat surface so the cuff is at heart level.
- Ensure clothing does not constrict your arm. Roll up sleeves if necessary.
4.2 Applying the Arm Cuff
The cuff should be applied directly to bare skin for best results.
- Slide the cuff onto your upper arm, ensuring the air tube points towards your forearm.
- The bottom edge of the cuff should be approximately 2-3 cm (about 2 fingers' width) above your elbow joint.
- Wrap the cuff snugly around your arm. It should be tight enough that you can only insert two fingers between the cuff and your arm.
- Ensure the artery mark on the cuff (if present) is aligned with your brachial artery (inner side of the upper arm).

Figure 4.1: Correct arm cuff placement.
This image illustrates the correct positioning of the arm cuff, emphasizing the two-finger rule for spacing above the elbow and tightness around the arm.
4.3 Taking a Measurement
Once the cuff is correctly applied and you are in a relaxed position:
- Press the START/STOP button. The cuff will begin to inflate automatically.
- Remain still and silent during the measurement. Do not talk or move your arm.
- The cuff will slowly deflate, and your blood pressure (systolic and diastolic) and pulse rate will be displayed on the screen.
- The measurement will automatically be saved to the selected user's memory.
- Press START/STOP again to turn off the device, or it will automatically shut off after a period of inactivity.

Figure 4.2: Blood Pressure Monitor display with readings.
This image shows the monitor's large, clear display presenting blood pressure readings (systolic and diastolic) and pulse rate, along with a color-coded indicator for blood pressure levels.

Figure 4.3: High-definition backlit screen for clear visibility.
This image emphasizes the monitor's backlit screen, designed for easy readability even in low-light environments.
4.4 Dual User Function and Memory
The monitor supports two users (User A and User B), each with 99 memory slots to store readings.
- To switch between User A and User B, press the SET button. The user icon (A or B) will change on the display.
- To view past measurements, press the MEM button. Each press will cycle through previous readings for the currently selected user.

Figure 4.4: Dual user memory function.
This image visually represents the monitor's capability to store separate measurement histories for two distinct users, labeled User A and User B, each with 99 memory slots.
5. Maintenance and Storage
5.1 Cleaning
- Wipe the monitor unit and cuff with a soft, dry cloth.
- If necessary, use a cloth lightly dampened with water or a mild detergent, then wipe dry immediately.
- Do not use abrasive cleaners, solvents, or immerse the device or cuff in water.
5.2 Storage
- Store the device and cuff in the provided storage bag when not in use.
- Keep the monitor in a cool, dry place, away from direct sunlight, extreme temperatures, and humidity.
- Avoid dropping the device or subjecting it to strong impacts.
6. Troubleshooting
If you encounter issues with your blood pressure monitor, refer to the following common problems and solutions. If the problem persists, contact customer support.
| Problem | Possible Cause | Solution |
|---|---|---|
| Device does not turn on. | Low battery or no charge. | Connect the device to a USB power source using the provided cable and charge fully. |
| Inaccurate or inconsistent readings. | Improper cuff placement, movement during measurement, or not resting before measurement. | Ensure correct cuff placement (refer to Section 4.2). Remain still and silent during measurement. Rest for at least 5 minutes before taking a reading. Take multiple readings and average them. |
| Cuff does not inflate or inflates too little/much. | Air tube not securely connected, or cuff is damaged. | Check that the air tube is firmly connected to the monitor. Inspect the cuff for any visible damage or leaks. |
| Display shows an error code (e.g., "E1", "Err"). | Measurement error, irregular heartbeat detected, or device malfunction. | Re-take the measurement following all instructions carefully. If the error persists, consult the full user manual for specific error code meanings or contact customer support. |
7. Specifications
| Feature | Detail |
|---|---|
| Model Number | C03-01 |
| Brand | Oklar |
| Measurement Method | Oscillometric |
| Measurement Location | Upper Arm |
| Memory Capacity | 2 Users x 99 Readings |
| Power Source | Rechargeable Battery (USB Charging) |
| Package Dimensions | 6.34 x 4.21 x 2.4 inches |
| Item Weight | 11.36 ounces |
| Manufacturer | Shenzhen Jamr Technology Co., Ltd. |
| UPC | 717886908923 |

Figure 7.1: Device dimensions.
This image provides the physical dimensions of the blood pressure monitor unit, indicating its height as 12.7 cm (5 inches) and width as 8.4 cm (3.3 inches).
8. Important Safety Information
Legal Disclaimer: Statements regarding dietary supplements have not been evaluated by the FDA and are not intended to diagnose, treat, cure, or prevent any disease or health condition.
This device is intended for general health monitoring and should not be used as a substitute for professional medical advice, diagnosis, or treatment. Always consult with a qualified healthcare professional for any health concerns or before making any decisions related to your health or treatment.