1. Safety Information
Important: Read all instructions carefully before installation and use. Failure to follow these instructions may result in property damage, personal injury, or death.
- Professional Installation Required: This mini-split AC system requires professional installation. Improper installation can lead to refrigerant leakage, electric shock, fire, or water leakage.
- Electrical Safety: Ensure the unit is properly grounded. All electrical work must be performed by a qualified electrician in accordance with national and local wiring regulations. Do not use an extension cord.
- Refrigerant: This unit uses R410A refrigerant. Handle with care and ensure proper ventilation during installation and servicing.
- Location: Do not install the unit near heat sources, steam sources, or in areas with flammable or explosive gases. Ensure no obstructions around the inlet and outlet of both indoor and outdoor units.
- Wall Strength: The wall for the indoor unit must be hard, flat, and firm to prevent vibration and noise.
- Outdoor Unit Placement: The outdoor unit must be installed in a firm and flat place to prevent vibration and noise. If installing at a height, operators must wear a safety belt and helmet.
2. Product Overview and Features
The Euker 9000 BTUs Mini Split Air Conditioner is an advanced inverter AC/heating system designed for efficient climate control in spaces up to 450 sq. ft. This ductless heat pump offers versatile functionality and smart features for enhanced comfort.
Key Features:
- Energy Efficient Cooling & Heating: With an impressive 23 SEER2 rating, this unit delivers powerful cooling and effective heating, significantly reducing energy consumption and utility bills.
- 4-in-1 Air Conditioning Modes: Offers Heating (up to 90°F), Cooling (down to 60°F), Fan (Low, Middle, High speed), and Drying (Dehumidification capacity: 56 Pints/Day) modes.
- Smart Control System: Built-in Wi-Fi connectivity allows seamless control via voice commands with Alexa or through your smartphone.
- Quiet Operation: Designed to operate at minimal noise levels, as low as 41dB, ensuring a peaceful environment ideal for bedrooms and offices.
- Timer Function: Features a built-in 0.5-24 hour timer for automatic shut-off, optimizing energy usage during sleep.
- Advanced Air Filtration: Equipped with a multi-stage filtration system to remove dust, pollen, and other airborne particles, improving indoor air quality. Features a detachable and easy-to-clean filter.
- Inverter Technology & ECO Mode: Provides more energy-efficient and money-saving operation compared to non-inverter systems.
- Swing Function: Allows for adjustable airflow to avoid direct blowing.

Figure 2.1: Euker Mini Split AC with Built-in Heat Pump, illustrating both cooling and heating capabilities.

Figure 2.2: Overview of the 4-in-1 air conditioning modes: Heating, Cooling, Fan, and Drying.

Figure 2.3: Illustration of the ultra-quiet operation (41dB) and 0.5-24 hour timing function, ideal for bedrooms.

Figure 2.4: Smart control system featuring Wi-Fi and smart voice control compatibility with Alexa.
3. Package Contents
The Euker Mini Split Air Conditioner package includes the following components:
- 1x Indoor Unit
- 1x Outdoor Condenser
- 1x 16.4 ft Copper & Aluminum Connection Pipe (Line Set)
- 1x Wall Mounting Bracket
- 1x Drain Hose
- 1x Communication Wires
- 1x User Guide
- Essential Accessories (e.g., wrapping tape, expansion screws, etc.)

Figure 3.1: Illustration of the complete package contents, typically delivered in two separate boxes.
4. Installation Guide
Note: Professional installation is required for this mini-split AC system. The following steps provide a general overview of the installation process.
4.1. Preparation Before Installation
Ensure the installation environment meets the following criteria:
- No heat source or steam source nearby.
- No obstructions around the inlet and outlet of both indoor and outdoor units.
- No smoke, oil, flammable, explosive, or corrosive gases present.
- The wall for the indoor unit must be hard, flat, and firm to avoid vibration and noise.
Indoor unit positioning requirements:
- To ceiling: > 15cm
- To obstacle (sides): > 20cm
- To floor: 230-260cm
4.2. Indoor Unit Installation
- Fix Mounting Plate: Put the mounting plate on the wall and use a level to ensure it is horizontal. Select the position for at least 5 screws. Use expansion screw kits to firmly fix the plate to the wall.
- Drill Wall Hole: After determining where the pipe will go through the wall, drill a hole. The wall hole should be inclined outward by 5-10 degrees, with a diameter of 60-80mm. Avoid wires, plumbing, gas, and other sensitive components.
- Install Connection Cable: Pass the power cable out from the back of the indoor unit and fix it on the terminal board. Fix the cable with a clamp.
- Knock-out Panel: According to the piping direction, remove the knock-out panel with a knife and remove burrs to prevent the drain pipe from being broken.
- Connect Refrigerant Piping: Use both hands to turn the pipe in the desired direction. Aim at the pipe center, tighten the taper nut with fingers, then tighten the taper nut with 2 wrenches. It is better to use a torque wrench to tighten the taper nut according to the specified torque values (refer to the table in the video for pipe size to torque conversion).
- Connect Drain Hose: Connect the drain hose with the water outlet pipe and fix it firmly with adhesive tape. The length should be more than 5cm to prevent water leakage.
- Wrap Piping: Wrap refrigerant piping, wires, and drain pipe with wrapping tape.
- Mount Indoor Unit: Put the refrigerant piping out of the wall hole. Push the lower part of the indoor unit until a 'click' sound is heard to make sure the indoor unit is firmly fixed to the wall.
- Pipe Protecting Ring and Putty: To protect piping and wires, a pipe protecting ring shall be installed and sealed with putty. Ensure the drain hose is sloped down and never put the end of the drain hose in the water.
4.3. Outdoor Unit Installation
- Select Installation Location: Outdoor unit must be installed in a firm and flat place to prevent vibration and noise. Ensure sufficient clearance: > 20cm to obstruction above, > 30cm to side obstructions, > 10cm air in side, > 200cm air out side.
- Install Outdoor Unit Bracket: If installing the air conditioner to a higher place, the operator should wear a safety belt and helmet. Use at least 6 expansion bolts to make sure brackets are fixed firmly on the wall.
- Fix Outdoor Unit: Put the outdoor unit onto the brackets. Use 4 screws to fix the feet of the outdoor unit.
- Connect Refrigerant Piping: Remove the nut from the stop valves. Aim at the pipe center of the stop valve, tighten the taper nut with fingers, then tighten the taper nut with 2 wrenches. It is better to use a torque wrench to tighten the taper nut according to the specified torque values (refer to the table in the video for pipe size to torque conversion).
- Fix Cables: Remove the electrical box cover. Fix cables to the terminal board according to the wiring diagram on the E-parts cover. Use a clamp to fix the cables. Must follow the wiring diagram inside the box cover. Put the electrical box cover back.
4.4. Vacuuming and Leak Check
- Connect Vacuum Pump: Connect the stop valve, charging hose, manifold valve, and vacuum pump as shown in the diagram (refer to video for visual).
- Vacuumize: Turn on the handle Lo to vacuumize.
- Pressure Check: Keep pressure for 3-5 minutes after vacuumizing. Make sure pressure springback is ≤0.05MPa.
- Release Refrigerant: Open the 1/4 liquid valve and remove the charging hose. Open all the liquid valves and gas valves. Screw all the caps and tighten up.
4.5. Trial Operation and Electrical Safety Check
- Electrical Safety Check: Use a multimeter to test for possible leaking position of the outdoor unit shell during trial operation. If there is electricity leakage, turn off power immediately to do further examination.
- Water Drain Check: Remove one filter. Pour in 500ml water along the evaporator for about 20 seconds. Check if water drain can normally flow out and if any water leakage is around the indoor unit.
Installation Video: Assembly of Mini Split AC/Heating System
Video 4.1: Detailed assembly instructions for the Mini Split AC/Heating System. This video covers preparation, indoor and outdoor unit installation, refrigerant piping, electrical connections, vacuuming, and trial operation.
Additional Installation Insights: MrCool Easy Pro 9k BTU 20 SEER Ductless Heat Pump System
Video 4.2: A short preview video offering additional insights into the installation process of a similar ductless heat pump system, focusing on key steps and considerations.
Mini Split Air Conditioner & Heater Installation Overview
Video 4.3: An overview of the installation process for a mini split air conditioner and heater, providing visual guidance for various steps.
5. Operating Instructions
The Euker Mini Split AC offers multiple operating modes and convenient control options.
5.1. Operating Modes
- Cool Mode: Provides powerful cooling to lower room temperature.
- Heat Mode: Utilizes heat pump technology for efficient heating during colder months.
- Dry Mode (Dehumidification): Reduces humidity levels in the room.
- Fan Mode: Circulates air without heating or cooling, with adjustable fan speeds (Low, Middle, High).
5.2. Remote Control
Use the included remote control to adjust settings from anywhere in the room. Functions include:
- Power On/Off
- Mode Selection
- Temperature Adjustment
- Fan Speed Control
- Timer Setting (0.5-24 hours)
- Sleep Mode Activation
- Swing Function Control
5.3. Smart Control (Wi-Fi & Voice)
With built-in Wi-Fi connectivity, you can manage your unit via a smartphone app or voice commands through Alexa. Refer to the dedicated app manual for detailed setup and usage instructions.
6. Maintenance
Regular maintenance ensures optimal performance and longevity of your Euker Mini Split AC.
6.1. Filter Cleaning
- The unit features a detachable and easy-to-clean filter.
- Clean the air filters regularly (e.g., every two weeks or as needed) to maintain air quality and unit efficiency.
- Refer to the detailed user guide for specific instructions on how to remove, clean, and re-install the filters.
6.2. General Care
- Wipe the indoor and outdoor units with a soft, dry cloth. For stubborn dirt, use a damp cloth with mild detergent, then wipe dry.
- Do not use harsh chemicals, abrasive cleaners, or solvents.
- Ensure the outdoor unit is free from debris, leaves, and other obstructions.
7. Troubleshooting
If you encounter issues with your Euker Mini Split AC, refer to the following general troubleshooting tips. For specific error codes or complex problems, consult the comprehensive user manual or contact customer support.
Common Issues:
- Unit Not Turning On: Check power supply, circuit breaker, and ensure the remote control batteries are functional.
- Insufficient Cooling/Heating: Verify temperature settings, ensure air filters are clean, and check for any obstructions to airflow.
- Unusual Noise: Check for loose parts or obstructions in the fan. If noise persists, contact a professional.
- Water Leakage: Ensure the drain hose is properly installed, sloped, and not blocked.
8. Specifications
| Specification | Value |
|---|---|
| Brand Name | Euker |
| Model Info | FTJ-SEER23 |
| Item Weight | 88.8 pounds |
| Product Dimensions | 13.39 x 33.07 x 23.82 inches |
| Efficiency | High |
| Capacity (Cooling Power) | 9000 British Thermal Units |
| Dehumidification Capacity | 56 Pints |
| Noise Level | 42 Decibels |
| Installation Type | Split System |
| Form Factor | Mini-Split |
| Special Features | Heating & Cooling Function |
| Color | White |
| Voltage | 230 Volts |
| Wattage | 730 watts |
| Floor Area Coverage | 450 Square Feet |
| Seasonal Energy Efficiency Ratio (SEER2) | 23 |
| Refrigerant | R 410A |
9. Warranty and Support
For warranty information, technical support, or service inquiries, please refer to the contact details provided in your product packaging or visit the official Euker website. Keep your purchase receipt as proof of purchase for warranty claims.