1. Introduction
This manual provides comprehensive instructions for the safe and effective operation of your YXJPP HO52-50M Digital Oscilloscope and Multimeter. This device integrates a dual-channel digital oscilloscope, a digital multimeter, and a signal source into a single portable unit, designed for various electronic testing and measurement applications.
Please read this manual thoroughly before using the device to ensure proper functionality and to prevent damage or injury.

Figure 1: YXJPP HO52-50M Digital Oscilloscope and Multimeter. This image displays the front view of the device, highlighting its screen, control buttons, and input ports for both oscilloscope and multimeter functions.
2. Safety Information
Always observe the following safety precautions to avoid personal injury and prevent damage to the instrument or other equipment.
- Do not use the device if it appears damaged or is not operating correctly.
- Ensure proper ventilation to prevent overheating.
- Do not operate the device in wet or damp conditions.
- Use only the specified power adapter and accessories.
- Always disconnect power before making or breaking connections to circuits.
- Be aware of voltage limits and current ratings for all inputs. Exceeding these limits can damage the device and pose a safety risk.
- Refer to the CAT III 600V rating for multimeter inputs, indicating suitability for measurements on distribution boards, circuit breakers, wiring, including cables, bus-bars, junction boxes, switches, socket outlets in the fixed installation, and industrial equipment permanently connected to the fixed installation.
3. Product Overview and Components
The HO52-50M features a clear display and intuitive controls for ease of use. Familiarize yourself with the various parts of the device as illustrated below.

Figure 2: HO52-50M Product Parameters Diagram. This diagram labels the key components and controls of the device, including the display area, function keys (F1-F4), navigation buttons, power switch, oscilloscope inputs (CH1, CH2), waveform generator output, multimeter input ports (A, mA, COM, QVC+), and the USB Type-C charging/communication port.
Key Components:
- Display Area: 3.5" TFT screen for waveform display and measurement readings.
- Function Keys (F1-F4): Context-sensitive keys for various menu options.
- Mode Button: Switches between Oscilloscope, Multimeter, and Signal Source modes.
- CH1/2 Button: Toggles between Channel 1 and Channel 2 in oscilloscope mode.
- System Button: Accesses system settings.
- Save Button: Saves waveforms or measurement data.
- Power Button: Turns the device on or off.
- Trig/Δ Button: Adjusts trigger settings in oscilloscope mode or relative value in multimeter mode.
- Navigation Keys: Up, Down, Left, Right, and OK for menu navigation and parameter adjustment.
- Measure/Range Button: Accesses measurement menu in oscilloscope mode or changes range in multimeter mode.
- Auto Button: Automatic setup for oscilloscope or automatic range for multimeter.
- Run/Stop Button (►/II): Starts or stops waveform acquisition.
- Oscilloscope Inputs (CH1, CH2): BNC connectors for oscilloscope probes.
- Waveform Generator Output (GEN Out): BNC connector for signal output.
- Multimeter Input Ports (A, mA, COM, QVC+): Input terminals for multimeter leads.
- USB Type-C Port: For charging and PC communication.
4. Setup
4.1 Initial Charging
Before first use, fully charge the device. Connect the provided USB Type-C cable to the device's USB port and the other end to a compatible USB power adapter (not included) or a computer's USB port. The charging indicator will show the charging status.
4.2 Powering On/Off
Press and hold the Power Button (labeled with a circle and vertical line) to turn the device on or off.
4.3 Probe Connection
- Oscilloscope Probes: Connect the BNC end of the oscilloscope probe to the CH1 or CH2 input. Ensure the probe is properly compensated before making critical measurements.
- Multimeter Leads: Insert the red test lead into the VΩmA or A input terminal and the black test lead into the COM terminal for multimeter measurements.
5. Operating Modes
The HO52-50M operates in three primary modes: Oscilloscope, Multimeter, and Signal Source. Use the Mode Button to switch between these functions.

Figure 3: 3-in-1 Functionality Display. This image illustrates the distinct display interfaces for the Oscilloscope, Multimeter, and Waveform Generator modes, showing a sine wave on the oscilloscope, a voltage reading on the multimeter, and waveform parameters on the generator.
5.1 Oscilloscope Mode
In Oscilloscope mode, the device displays voltage waveforms over time. It features dual-channel input with a 50MHz bandwidth and a real-time sampling rate of 250MSa/s.
- Channel Selection: Press CH1/2 to select or toggle between Channel 1 and Channel 2.
- Automatic Setup: Press the Auto Button for automatic scaling and positioning of the waveform. This is useful for quickly getting a stable display.
- Vertical Control (Voltage/Div): Use the navigation keys (Up/Down) to adjust the vertical scale (Volts per Division) for the selected channel.
- Horizontal Control (Time/Div): Use the navigation keys (Left/Right) to adjust the horizontal scale (Time per Division).
- Trigger Settings: Press Trig/Δ to access trigger menu options. Adjust trigger level, type (edge, pulse), and source using the navigation keys and function buttons.
- Measurements: Press Measure/Range to display automatic measurements such as frequency, peak-to-peak voltage, RMS, etc. The device supports 7 types of automatic measurement functions.
- Run/Stop: Press ►/II to pause or resume waveform acquisition.
5.2 Multimeter Mode
The integrated multimeter allows for precise measurements of voltage, current, resistance, capacitance, and diode/continuity tests.
- Function Selection: Use the function keys (F1-F4) or navigation keys to select the desired measurement function (e.g., DCV, ACV, DCA, ACA, Resistance, Diode, Continuity, Capacitance).
- Automatic Ranging: Press the Auto Button for automatic range selection. Manual ranging can be selected via the Measure/Range button.
- Connecting Leads: Ensure test leads are connected to the correct input terminals (VΩmA, A, COM) for the selected measurement type.
- Relative Value: Press Trig/Δ to activate the relative measurement function, displaying the difference from a stored reference value.
5.3 Signal Source Mode
The device can generate various waveforms for testing circuits.
- Waveform Type: Use function keys to select waveform types (e.g., Sine, Square, Triangle, Pulse).
- Frequency/Amplitude/Offset Adjustment: Use navigation keys to adjust parameters such as frequency, amplitude (Vpp), and DC offset.
- Output Connection: Connect a BNC cable from the GEN Out port to the circuit under test.
6. Maintenance
6.1 Cleaning
Clean the device regularly with a soft, damp cloth. Do not use abrasive cleaners or solvents. Ensure the device is powered off and disconnected from all power sources before cleaning.
6.2 Battery Care
The device contains a rechargeable battery. To prolong battery life:
- Avoid fully discharging the battery frequently.
- Store the device in a cool, dry place if not used for extended periods.
- Recharge the battery periodically (e.g., every 3 months) even if not in use.
7. Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| Device does not power on. | Battery is discharged. | Connect to a power source and charge the device. |
| No waveform displayed in oscilloscope mode. |
|
|
| Multimeter readings are inaccurate. |
|
|
8. Specifications
The following are the technical specifications for the YXJPP HO52-50M Digital Oscilloscope and Multimeter:
- Model: HO52-50M
- Display: 3.5" TFT Color Display, 320*240 Pixels
- Oscilloscope Channels: 2
- Bandwidth: 50MHz
- Real-Time Sampling Rate: 250MSa/s
- Record Length: 8K points
- Max Waveform Capture Rate: 30,000 wfm/s
- Automatic Measurement Functions: 7 types
- Multimeter Input Rating: CAT III 600V
- Interface: USB Type-C (for charging and PC connection)
- Power Source: Rechargeable battery, USB Type-C charging

Figure 4: HO52-50M in Various Applications. This image demonstrates the versatility of the device, showing it connected to a PC, charging via USB Type-C, being used for electronic repair, and in an educational or research setting.

Figure 5: HO52-50M Efficiency and Precision. This image compares the compact HO52-50M with larger, traditional lab equipment, highlighting its ability to perform similar functions in a more portable and efficient form factor for oscilloscope, multimeter, and waveform generator tasks.
9. Warranty and Support
For warranty information and technical support, please refer to the product packaging or contact the manufacturer directly. Keep your purchase receipt as proof of purchase.