1. Introduction
Thank you for choosing the CIGMAN CD60R Bilateral Laser Distance Meter. This device is designed for precise and efficient distance measurement, offering a range of functions for various applications. Please read this manual carefully before using the device to ensure safe and correct operation.

Image 1: CIGMAN CD60R Laser Distance Meter
2. Safety Information
This device emits a Class II laser. Observe the following safety precautions:
- Do not stare directly into the laser beam.
- Do not aim the laser beam at people or animals.
- Avoid direct eye exposure to the laser beam.
- Do not disassemble or modify the device.
- Keep the device out of reach of children.
3. Product Overview
The CIGMAN CD60R offers advanced features for accurate and convenient measurements:
- Measurement Units: Supports M/in/Ft.
- Measurement Methods: 11 distinct measurement functions.
- Bilateral Laser Measurement: Measures from two directions simultaneously, enhancing efficiency.
- Digital Bubble Level: Integrated for precise leveling.
- Automatic Rotating Screen: Adapts display orientation for ease of use.
- Color IPS Backlight Display: Provides clear readability in various lighting conditions.
- Magnetic Attraction: Allows attachment to metal surfaces for stable measurements.
- Data Storage: Stores up to 100 sets of historical data.
- Addition/Subtraction: Perform calculations directly on the device.
- Durability: IP54 dust and water resistant, with an anti-slip rubberized body.

Image 2: Overview of CIGMAN CD60R features
4. Setup
4.1. Charging the Battery
The device is equipped with an 850mAh rechargeable lithium battery. Use the provided Type-C charging cable to charge the device. A full charge provides over 5,500 measurements.
- Connect the Type-C cable to the charging port on the device.
- Connect the other end of the cable to a compatible USB power adapter (not included).
- The battery indicator on the display will show charging status.

Image 3: Device charging via Type-C port
4.2. Power On/Off
Press the MEAS button to power on the device. Press and hold the OFF/CLEAR button to power off.
5. Operating Instructions
5.1. Basic Measurement
To perform a single measurement:
- Point the laser at the target surface.
- Press the MEAS button. The measured distance will appear on the screen.
For continuous measurement:
- Press and hold the MEAS button. The device will continuously measure and display the distance.
- Release the MEAS button to stop continuous measurement.
5.2. Bilateral Laser Measurement
The CD60R features bilateral laser technology, allowing measurements from two points simultaneously. This is particularly useful for measuring heights or lengths without needing to move the device to the start or end point.
Video 1: Demonstration of bilateral laser measurement in action.

Image 4: Diagram illustrating 120M bilateral laser measurement capability.
5.3. Unit Switching
The device supports multiple units of measurement. Press the FUNC/RECORD button to cycle through available units: meters (m), inches (in), and feet (ft). Fine-tune display formats such as 0.000m, 0.00m, 0.00ft, 0.0in, 1/16in, and 0'00".

Image 5: Display showing various unit conversion options.
5.4. Data Storage
The CD60R can store up to 100 sets of measurement data. This allows for convenient recall and review of past measurements.

Image 6: Device display showing stored data sets.
5.5. Adaptive Rotating Screen
The display automatically rotates to match the device's orientation, ensuring clear readability whether held horizontally or vertically.

Image 7: Device display rotating for horizontal and vertical measurements.
5.6. Magnetic Attraction
The integrated magnetic base allows the device to be securely attached to metal surfaces, providing stability for hands-free measurements.

Image 8: Device attached to a metal surface using magnetic attraction.
5.7. Digital Bubble Level
The built-in digital bubble level assists in achieving accurate horizontal and vertical alignment for measurements.

Image 9: Device displaying angle measurement with digital bubble level.
6. Measurement Modes
The CIGMAN CD60R supports 11 different measurement modes:
- Length Measurement: Standard distance measurement.
- Area Measurement: Calculates the area of a surface.
- Volume Measurement: Calculates the volume of a space.
- Wall Area Measurement: Measures the total area of multiple walls.
- Electronic Angle Mode: Measures angles using the integrated tilt sensor.
- Angle and Height: Combines angle and distance for height calculations.
- Indirect Height (Pythagorean): Uses Pythagorean theorem for height measurement from two points.
- Hypotenuse Measurement: Calculates the hypotenuse of a right triangle.
- Auxiliary Height: Measures height using an auxiliary point.
- Double Indirect Height: Measures height from multiple indirect points.
- Electronic Bubble Level: Provides a digital level for alignment.

Image 10: Icons illustrating the different measurement modes.

Image 11: Diagrams explaining how different measurement calculations are performed.
7. Maintenance
The CIGMAN CD60R is designed for durability with an IP54 rating, providing protection against dust and splashing water. To ensure optimal performance and longevity:
- Keep the device clean and free from dust and debris.
- Wipe the lens with a soft, dry cloth.
- Avoid exposing the device to extreme temperatures or direct sunlight for extended periods.
- Store the device in its protective pouch when not in use.

Image 12: Device demonstrating IP54 protection against water splashes.
8. Troubleshooting
If you encounter issues with your CIGMAN CD60R, consider the following general troubleshooting steps:
- Device not powering on: Ensure the battery is sufficiently charged. Connect the device to a Type-C charger.
- Inaccurate measurements: Ensure the laser lens is clean. Verify the measurement reference point is correctly set. Perform manual calibration if necessary.
- Display issues: Check battery level. If the screen is unresponsive, try restarting the device.
For further assistance, please contact CIGMAN customer support.

Image 13: Device display showing manual calibration option.
9. Specifications
| Feature | Detail |
|---|---|
| Brand | CIGMAN |
| Model Number | CD60R |
| Measuring Range | 120m / 393ft |
| Accuracy | ± 1/8 inch (2mm) |
| Laser Class | Class II, <1mW |
| IP Rating | IP54 |
| Battery Type | Rechargeable Lithium Battery (850mAh) |
| Battery Life | >5500 measurements per charge |
| Charging Port | Type-C |
| Material | Acrylonitrile Butadiene Styrene |
| Color | Blue |
10. Warranty and Support
CIGMAN provides a 3-year after-sales service for this product. If you have any questions or require technical assistance, please do not hesitate to contact CIGMAN customer support. Your package includes:
- 1x CIGMAN CD-60R Bilateral Laser Distance Meter
- 1x Charging Cable
- 1x Storage Bag
- 1x User Manual
- 1x Wrist Strap
- 1x Reflector