Équinox 527540 GERS EQUIPEMENT

Équinox Digital Cooking Thermometer

Model: 527540 GERS EQUIPEMENT

1. Introduction

This user manual provides detailed instructions for the safe and efficient operation of your Équinox Digital Cooking Thermometer, Model 527540 GERS EQUIPEMENT. This device is designed to accurately measure internal food temperatures and includes an integrated timer, allowing for precise cooking results. Please read this manual thoroughly before first use and retain it for future reference.

2. Safety Information

  • Do not immerse the main unit in water or other liquids. The probe is waterproof, but the main unit is not.
  • Keep the probe and cable away from direct flames or heating elements to prevent damage.
  • The probe tip is sharp; handle with care to avoid injury.
  • Keep out of reach of children.
  • Do not attempt to disassemble or modify the device. This will void the warranty.
  • Use only the specified battery type (1x AAA/LR3).
  • The maximum temperature rating for the probe is 250°C (482°F). Do not exceed this temperature.

3. Package Contents

  • 1 x Équinox Digital Cooking Thermometer Main Unit
  • 1 x Stainless Steel Temperature Probe with Cable
  • 1 x User Manual
  • Note: 1x AAA/LR3 battery is not included.

4. Product Overview

Familiarize yourself with the components of your digital cooking thermometer:

Équinox Digital Cooking Thermometer front view with probe

Figure 1: Front view of the Équinox Digital Cooking Thermometer, showing the display, control buttons (MIN, SEC, °C/°F S/S, RESET), and the connected temperature probe.

Équinox Digital Cooking Thermometer side view with stand

Figure 2: Side view of the Équinox Digital Cooking Thermometer, illustrating the integrated stand for tabletop placement and the magnetic back for attachment to metal surfaces.

  1. LCD Display: Shows temperature and timer readings.
  2. MIN Button: Used to set minutes for the timer or adjust settings.
  3. SEC Button: Used to set seconds for the timer or adjust settings.
  4. °C/°F S/S Button: Toggles between Celsius and Fahrenheit temperature units. Also functions as Start/Stop for the timer.
  5. RESET Button: Resets timer or clears settings.
  6. Probe Input Jack: Connects the temperature probe.
  7. Temperature Probe: Stainless steel probe for measuring food temperature.
  8. Magnetic Back: Allows attachment to metallic surfaces (e.g., oven door, refrigerator).
  9. Fold-out Stand: For tabletop use.
  10. Battery Compartment: Located on the back, for 1x AAA/LR3 battery.

5. Setup

5.1 Battery Installation

  1. Locate the battery compartment on the back of the main unit.
  2. Open the battery compartment cover.
  3. Insert one AAA/LR3 battery, ensuring correct polarity (+/-).
  4. Close the battery compartment cover securely.

5.2 Probe Connection

  • Insert the probe cable connector firmly into the probe input jack on the side of the main unit.
  • Ensure the connection is secure to prevent inaccurate readings.

6. Operating Instructions

6.1 Power On/Off

The device typically powers on automatically when a battery is inserted and the probe is connected. There is no dedicated power button. It will enter a low-power state after a period of inactivity.

6.2 Temperature Measurement

  1. Insert the stainless steel probe into the thickest part of the food, avoiding bone or gristle.
  2. The current internal temperature will be displayed on the LCD screen.
  3. To switch between Celsius (°C) and Fahrenheit (°F), press the °C/°F S/S button.

6.3 Setting a Target Temperature (Alarm Function)

This feature allows you to set a desired target temperature. An alarm will sound when the food reaches this temperature.

  1. While in temperature mode, press the MIN button to increase the target temperature.
  2. Press the SEC button to decrease the target temperature.
  3. Once the desired target temperature is set, the thermometer will continuously monitor the food's temperature.
  4. When the food reaches the target temperature, an audible alarm will sound.
  5. Press any button to silence the alarm.

6.4 Timer Function

The device can also function as a countdown timer.

  1. Press the MIN button to set the desired minutes.
  2. Press the SEC button to set the desired seconds.
  3. Press the °C/°F S/S button to start the countdown.
  4. To pause the timer, press the °C/°F S/S button again. Press it once more to resume.
  5. When the timer reaches zero, an audible alarm will sound.
  6. Press any button to silence the alarm.
  7. To reset the timer, press the RESET button.

7. Maintenance

7.1 Cleaning

  • Clean the stainless steel probe with warm soapy water after each use. Rinse thoroughly and dry completely.
  • Wipe the main unit with a damp cloth. Do not immerse the main unit in water.
  • Do not use abrasive cleaners or scouring pads, as these may damage the unit.

7.2 Storage

  • Store the thermometer in a clean, dry place when not in use.
  • If storing for an extended period, remove the battery to prevent leakage.

8. Troubleshooting

ProblemPossible CauseSolution
No display or faint displayLow or dead battery; incorrect battery polarity.Replace battery with a new AAA/LR3 battery; ensure correct polarity.
Inaccurate temperature readingsProbe not fully inserted; probe cable loose; probe damaged.Ensure probe is fully inserted into food; check probe cable connection; if probe is damaged, replacement may be necessary.
Alarm not soundingVolume too low (if adjustable, though this model doesn't specify); alarm function not activated.Ensure target temperature is set correctly for temperature alarm or timer is running for timer alarm.
Timer not workingTimer not started; incorrect time set.Press S/S button to start timer; ensure minutes and seconds are set before starting.

9. Specifications

  • Model: 527540 GERS EQUIPEMENT
  • Dimensions (L x W x H): 13 x 2.8 x 23.5 cm (Product packaging dimensions: 13 x 2.8 x 23.5 cm)
  • Weight: 110 g
  • Power Source: 1 x AAA/LR3 Battery (not included)
  • Temperature Range: Up to 250°C (482°F)
  • Display Type: Digital
  • Material: Stainless steel probe
  • Features: Integrated timer, magnetic back, fold-out stand

10. Warranty and Support

Équinox products are manufactured with quality and reliability in mind. This product comes with a standard manufacturer's warranty against defects in materials and workmanship. Please refer to your purchase documentation for specific warranty terms and duration.

For technical support, troubleshooting assistance, or warranty claims, please contact your retailer or the Équinox customer service department. Contact information can typically be found on the product packaging or the retailer's website.

Related Documents - 527540 GERS EQUIPEMENT

Preview Catalogue Distribution Professionnelle 2025 - Resideo
Découvrez le catalogue 2025 de Resideo pour la distribution professionnelle, présentant une gamme complète de solutions pour la régulation de pression d'eau, le chauffage, l'hydraulique et la sécurité.
Preview MAXXUS Support Mural Pliable pour Sac de Frappe: Manuel d'Installation et d'Utilisation
Manuel d'installation et d'utilisation complet pour le MAXXUS Support Mural Pliable pour Sac de Frappe (Modèle GSMX-600123-00019-0001). Inclut informations de sécurité, instructions de montage, entretien, conseils d'entraînement et détails de garantie.
Preview GYS DRAW ALIGNER PRO - Manuel d'utilisation et de sécurité
Guide complet pour l'utilisation, l'assemblage, la maintenance et la sécurité du GYS DRAW ALIGNER PRO, un équipement professionnel pour le redressage de carrosseries automobiles.
Preview GYS CUTTER 45 CT - Manuel d'utilisation et guide de sécurité
Manuel d'utilisation complet pour le GYS CUTTER 45 CT. Découvrez les instructions de sécurité, d'installation, d'utilisation, de maintenance et de dépannage pour une performance optimale et une utilisation sûre.
Preview MOVIT Appui-tête Mobile de Massage - Manuel d'Utilisation et Informations de Sécurité
Guide complet pour l'Appui-tête Mobile de Massage MOVIT, couvrant les instructions de sécurité, l'utilisation, l'entretien, la garantie et les exercices. Apprenez à utiliser votre appui-tête de massage en toute sécurité et efficacité.
Preview Manuel d'utilisation Algam Lighting NEBEL3000-ABS Machine à Fumée Lourde
Découvrez le manuel d'utilisation complet pour la machine à fumée lourde Algam Lighting NEBEL3000-ABS. Ce guide détaille l'installation, l'utilisation, la maintenance et les spécifications techniques pour un fonctionnement professionnel.