Important Safety Instructions
Please read all instructions carefully before installation and operation. Keep this manual for future reference.
- Professional Installation Recommended: For optimal performance and safety, professional installation is strongly advised.
- Upright Position: Ensure the unit remains in an upright position for at least 24 hours prior to use to allow refrigerants to settle.
- Electrical Safety: Connect the unit to a properly grounded electrical outlet with the correct voltage (115V). Do not use extension cords.
- Clearances: Maintain adequate clearances around both indoor and outdoor units for proper airflow and maintenance.
- Children and Pets: Keep children and pets away from the unit during operation and maintenance.
- Flammable Materials: Do not store or use flammable liquids or gases near the air conditioner.
Product Overview
The Euker 9,000 BTU Mini Split Air Conditioner is a versatile system designed for efficient cooling and heating of spaces up to 450 sq.ft. It features smart control options, energy-saving technology, and multiple operating modes.
Product Components
Your Euker Mini Split AC system includes the following main components and accessories:

Figure 1: Main product view showing the indoor unit (wall mount air handler), outdoor unit (condenser), remote control, and various installation accessories including copper line set, drainage extension, and communication wires.

Figure 2: Detailed view of the indoor and outdoor unit dimensions, along with the pre-flared and insulated copper line set (16.4 FT), drainage extension with small accessories, and communication wires.
Setup and Installation
Proper installation is crucial for the efficient and safe operation of your mini split system. While this section provides general guidelines, professional installation is highly recommended.
Pre-Installation Checks
- Verify that the chosen installation location for both indoor and outdoor units meets clearance requirements and can support the unit's weight.
- Ensure the electrical supply matches the unit's voltage (115V) and is properly grounded.
- Confirm all included components and accessories are present as shown in Figure 1 and Figure 2.
Connecting Components
- Refrigerant Lines: Connect the pre-flared and insulated copper line set (16.4 FT) between the indoor and outdoor units. Ensure connections are tight to prevent leaks.
- Drainage: Install the drainage extension to the indoor unit to ensure proper condensate removal.
- Electrical Wiring: Connect the communication wires between the indoor and outdoor units, and the main power supply to the outdoor unit, following local electrical codes and the wiring diagram provided in the full installation manual.
Operating Instructions
Your Euker Mini Split AC offers multiple ways to control your comfort and a variety of operating modes.
Control Methods
- Remote Control: Use the included backlit LCD remote controller for direct control of all functions.
- WiFi Control: Download the dedicated app to control your unit remotely via WiFi from your smartphone.
- AI Voice Control: The system supports AI voice control for convenient hands-free operation.

Figure 3: The Euker Mini Split AC can be controlled via the included remote control, a smartphone app for WiFi control, and supports AI voice control for convenience.
Operating Modes
The unit offers five primary operating modes to suit your climate control needs:
- Cool Mode: Provides cooling down to 60°F.
- Heat Mode: Provides heating up to 89°F, even in low temperatures as low as -4°F (-20°C).
- Fan Mode: Circulates air without heating or cooling. Offers four fan speeds.
- Dry Mode (Dehumidification): Removes excess moisture from the air, with a capacity of 48 Pints/day.
- Auto Mode: Automatically selects the appropriate mode (Cool, Heat, or Fan) based on the ambient temperature and desired setting.

Figure 4: The Euker Mini Split AC offers 4-in-1 functionality, including Cool, Heat, Fan, and Dry (dehumidification) modes.

Figure 5: The unit provides fast cooling to 60°F and fast heating to 89°F, ensuring rapid comfort.
Special Features
- Sleep Mode: Adjusts temperature and fan speed for comfortable sleep, ensuring ultra-silent operation at only 27 dB.
- ECO Mode: Optimizes energy consumption for greater efficiency.
- IFEEL Function: The remote control senses the temperature around it and transmits the signal back to the indoor unit, allowing the unit to adjust airflow for localized comfort.
- Turbo Function: Provides rapid cooling or heating to quickly reach the desired temperature.
- Self-Cleaning: The indoor unit automatically cleans its interior to maintain fresh, clean air.
- Auto Defrost: The outdoor unit features an auto-defrost function that activates at low temperatures (-4°F/-20°C) to prevent ice buildup and enhance efficiency.

Figure 6: The Euker Mini Split AC operates quietly at 27 dB in sleep mode, providing a peaceful environment and gentle airflow.

Figure 7: The 19 SEER rating indicates high energy efficiency, leading to significant energy and cost savings.
Maintenance
Regular maintenance ensures the longevity and efficient operation of your Euker Mini Split AC.
Care and Cleaning
- Filter Cleaning: The unit features a washable filter. Regularly remove and clean the filter to maintain optimal airflow and air quality. Refer to the full manual for detailed instructions on filter removal and cleaning frequency.
- Self-Cleaning Function: Utilize the self-cleaning function to automatically clean the indoor unit's interior, preventing mold and bacteria buildup.
- Exterior Cleaning: Wipe the exterior of both indoor and outdoor units with a soft, damp cloth. Do not use harsh chemicals or abrasive cleaners.
- Outdoor Unit: Keep the area around the outdoor condenser clear of debris, leaves, and other obstructions to ensure proper airflow.
Troubleshooting
Before contacting customer support, please refer to the following table for common issues and their potential solutions.
| Problem | Possible Cause | Solution |
|---|---|---|
| Unit does not turn on | No power supply; Remote control batteries dead; Circuit breaker tripped. | Check power connection; Replace remote batteries; Reset circuit breaker. |
| Insufficient cooling/heating | Dirty air filter; Obstruction to airflow; Incorrect mode selected; Room size too large. | Clean or replace air filter; Remove obstructions; Select correct mode; Ensure unit capacity matches room size. |
| Unusual noise | Loose parts; Unit not level; Debris in fan. | Check for loose components; Ensure unit is level; Inspect for and remove debris. |
| Water leakage from indoor unit | Clogged drain hose; Improper installation. | Clear drain hose; Contact professional installer for inspection. |
| Remote control not working | Batteries dead or incorrectly inserted; Obstruction between remote and unit. | Replace batteries; Ensure clear line of sight to indoor unit's receiver. |
Technical Specifications
| Feature | Specification |
|---|---|
| Brand | Euker |
| Cooling Power | 9,000 British Thermal Units (BTU) |
| Seasonal Energy Efficiency Ratio (SEER) | 19 |
| Voltage | 115 Volts |
| Dehumidification Capacity | 48 Pints/day |
| Indoor Unit Dimensions (W x H x D) | 31.92" x 8.07" x 11.49" |
| Outdoor Unit Dimensions (W x H x D) | 28.14" x 19.61" x 11.42" |
| Noise Level (Indoor) | As low as 27 dB |
| Operating Temperature Range (Cooling) | 60°F to 89°F |
| Operating Temperature Range (Heating) | 60°F to 89°F (down to -4°F / -20°C outdoor) |
| Special Features | Remote Controlled, WiFi Control, AI Voice Control, Self-Cleaning, Auto Defrost, Sleep Mode, ECO Mode, IFEEL, Turbo |
| Color | White |
Warranty and Support
Euker is dedicated to providing the best shopping experience and stands firmly behind its product. While specific warranty details are provided at the time of purchase, general support is available for any questions or concerns.
For technical assistance, troubleshooting beyond this manual, or warranty claims, please refer to the contact information provided with your purchase documentation or visit the official Euker website.
Professional installation is recommended to ensure proper operation and to validate any applicable warranties.