1. Introduction
The ETURBEV IO53A02 is a versatile DC/AC motor forward and reverse controller designed for various time control applications. This module features adjustable delay times, cycle settings, and multiple control modes, making it suitable for a wide range of industrial and scientific projects requiring precise motor control or timed relay operations.
This manual provides detailed instructions for the proper setup, operation, and maintenance of your IO53A02 module to ensure optimal performance and longevity.
2. Product Features
- Dual Power Supply Options: Supports DC 6.5-25V (Power Supply 1) and DC 5V (Power Supply 2). Note: Only one power source should be connected at a time.
- Operating Modes: Normal mode (standby current 41mA, working current 83mA) and Energy-saving mode (standby current 7mA, working current 44mA).
- Input Control Ports: Dedicated inputs for Forward (FWD), Reverse (REV), and Stop (STOP) control.
- Trigger Modes: Supports low pulse trigger (falling edge) and low-level trigger (rising edge).
- Adjustable Delay Time: Configurable from 0.1 to 9999.9 seconds, 1 to 9999 seconds, or 1 to 999 minutes.
- Cycle Settings: Options for no cycles, 2-99 cycles, or continuous cycling.
- Indicator Lights: Visual feedback for Forward (F LED), Reverse (R LED), and Stop (S LED) states.
- Relay Load Capacity: Recommended load current for the relay is less than 5A.
3. Specifications
| Parameter | Value |
|---|---|
| Model | IO53A02 |
| Power Supply 1 (DC Jack) | DC 5V |
| Power Supply 2 (VIN/GND Terminals) | DC 6.5-25V |
| Working Current (Normal Mode) | 83mA |
| Standby Current (Normal Mode) | 41mA |
| Working Current (Energy Saving Mode) | 44mA |
| Standby Current (Energy Saving Mode) | 7mA |
| Relay Load Current (Max) | 5A (Recommended) |
| Delay Time Range | 0.1-9999.9s, 1-9999s, 1-999min |
| Trigger Modes | Low Pulse Trigger, Low-Level Trigger |
| Dimensions | Approx. 8cm x 5.1cm (3.14in x 2.00in) |
| Weight | 50 Grams |

Figure 1: Module dimensions showing approximate length of 8cm (3.14in) and width of 5.1cm (2.00in).
4. Setup and Installation
Before connecting the module, ensure all power sources are disconnected. Observe proper polarity for all connections.

Figure 2: Overview of the IO53A02 module showing power inputs, control inputs, and motor/relay outputs.
4.1 Power Supply Connection
- Option 1 (DC 5V): Connect a 5V DC power adapter to the DC 5.5 female jack on the module.
- Option 2 (DC 6.5-25V): Connect your DC 6.5-25V power source to the VIN (positive) and GND (negative) screw terminals.
- Important: Do not connect both power supply options simultaneously. Choose only one.
4.2 Motor/Load Connection
- Connect the motor or load to the M+ and M- screw terminals. These are the relay output terminals.
- Connect the motor's power supply to the P+ (positive) and P- (negative) screw terminals. Ensure this power supply matches the motor's voltage requirements.
- The relay's maximum recommended load current is 5A. Exceeding this may damage the module.
4.3 Input Control Connections
The module features three input control ports for external triggering:
- FWD (Forward): Connect your forward control signal here.
- REV (Reverse): Connect your reverse control signal here.
- STOP (Stop): Connect your stop control signal here.
- These inputs typically respond to low pulse or low-level triggers, depending on the configured mode.
5. Operating Instructions
The IO53A02 module is configured using the onboard buttons (SET, ++, --, OK) and the 4-digit display. The specific operational modes and parameter settings are detailed below.
5.1 Button Functions
- SET: Enters/exits parameter setting mode, cycles through parameters.
- ++: Increases the currently selected parameter value.
- --: Decreases the currently selected parameter value.
- OK: Confirms the current setting and saves it, or exits a menu.

Figure 3: Detail of the display and control buttons (SET, ++, --, OK) for parameter configuration.
5.2 Setting Delay Times (T1, T2)
The module uses two primary timers, T1 (Forward Timer) and T2 (Reverse Timer), for controlling the duration of forward and reverse operations, or other timed events depending on the mode.
- Press the SET button briefly to enter parameter setting mode. The display will show "P-X" (Program Mode) or a timer value.
- Use ++ or -- to navigate to the desired timer setting (e.g., T1 or T2).
- Press SET again to select the timer. The display will show the current time value.
- Use ++ or -- to adjust the numerical value.
- Press OK to confirm the numerical value.
- After setting the value, the display may show the time unit (e.g., "S" for seconds, "M" for minutes, "0.1S" for tenths of seconds). Use ++ or -- to select the desired unit.
- Press OK to confirm the time unit.
- Repeat for the other timer (T2) if applicable to your chosen operating mode.
- Press and hold SET to exit parameter setting mode and save all changes.
Delay Time Ranges:
- 0.1 - 9999.9 seconds
- 1 - 9999 seconds
- 1 - 999 minutes
5.3 Setting Cycle Count
Some operating modes allow for repetitive cycles. The cycle count can be set as follows:
- Enter parameter setting mode by pressing SET.
- Navigate using ++ or -- to the cycle count parameter (e.g., "C-XX").
- Press SET to select.
- Use ++ or -- to set the desired number of cycles (2-99).
- Special settings: "00" typically means no cycles (single operation), and "LL" or similar might indicate continuous cycling.
- Press OK to confirm.
- Press and hold SET to exit and save.
5.4 Selecting Trigger Mode
The module supports two trigger modes for its input control ports (FWD, REV, STOP):
- Low Pulse Trigger (Falling Edge Trigger): The module reacts to a momentary transition from high to low voltage on the input pin.
- Low-Level Trigger (Rising Edge Trigger): The module reacts when the input pin is held at a low voltage level.
To select the trigger mode:
- Enter parameter setting mode by pressing SET.
- Navigate using ++ or -- to the trigger mode parameter (e.g., "Trig").
- Press SET to select.
- Use ++ or -- to toggle between "PULSE" (Low Pulse) and "LEVEL" (Low-Level).
- Press OK to confirm.
- Press and hold SET to exit and save.
5.5 Indicator Lights
- F LED (Forward): Illuminates when the module is in a forward operation state.
- R LED (Reverse): Illuminates when the module is in a reverse operation state.
- S LED (Stop): Illuminates when the module is in a stop or idle state.
6. Maintenance
- Cleaning: Keep the module clean and free from dust and debris. Use a soft, dry cloth for cleaning. Avoid liquid cleaners.
- Environment: Operate the module within its specified temperature and humidity ranges. Avoid exposure to extreme temperatures, moisture, or corrosive environments.
- Connections: Periodically check all wiring connections to ensure they are secure and free from corrosion.
- Power Supply: Always use a stable and appropriate power supply within the specified voltage range.
7. Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| Module does not power on. | Incorrect power supply voltage or polarity. Loose power connection. Both power inputs connected. | Verify power supply voltage (5V or 6.5-25V) and polarity. Ensure connections are secure. Disconnect one of the power inputs if both are connected. |
| Motor/Load does not activate. | Incorrect motor/load wiring. Load current exceeds 5A. Incorrect operating mode or timer settings. No trigger signal. | Check M+/M- and P+/P- connections. Ensure load current is below 5A. Review operating mode and timer settings. Verify trigger signal is being sent correctly. |
| Module not responding to FWD/REV/STOP inputs. | Incorrect trigger mode selected. Input signal issue. | Check if the trigger mode (Low Pulse/Low-Level) matches your input signal. Verify the input signal is correctly applied to the FWD, REV, or STOP terminals. |
| Display shows erratic characters. | Unstable power supply. Electromagnetic interference. | Ensure a stable power supply. Relocate the module away from strong electromagnetic fields. |
8. Warranty and Support
This ETURBEV product is designed for reliability and performance. For any technical assistance or warranty inquiries, please refer to the retailer or manufacturer's support channels where the product was purchased.
Please retain your proof of purchase for warranty claims.