La Crosse Technology Atomic Projection Alarm Clock

La Crosse Technology Atomic Projection Alarm Clock User Manual

Model: Atomic Projection Alarm Clock

Introduction

This manual provides comprehensive instructions for the setup, operation, and maintenance of your La Crosse Technology Atomic Projection Alarm Clock. Please read this manual thoroughly before use to ensure proper functionality and to maximize your product experience.

Package Contents

Note: 3 AAA batteries are required for backup but are not included.

Product Overview

The La Crosse Technology Atomic Projection Alarm Clock features an LCD display, atomic time synchronization, and a projection function to display time on a wall or ceiling. It also includes indoor and outdoor temperature readings.

La Crosse Technology Atomic Projection Alarm Clock with projector extended

Figure 1: Front view of the La Crosse Technology Atomic Projection Alarm Clock with its projection arm extended. The LCD displays time, day, and indoor/outdoor temperatures.

Key Components:

Setup

1. Powering the Clock

  1. Insert 3 new AAA batteries (not included) into the battery compartment on the back of the clock. Ensure correct polarity (+/-). These batteries provide backup power during outages.
  2. Connect the included power adapter to the clock's power input jack and then plug it into a standard electrical outlet. The LCD display will illuminate.

2. Initial Time Synchronization (Atomic Time)

Upon initial power-up, the clock will automatically attempt to synchronize with the WWVB atomic time signal. This process may take several minutes to several hours, depending on your location and signal strength. Look for the atomic signal icon on the display to confirm successful synchronization.

3. Remote Temperature Sensor Setup

La Crosse Technology Atomic Projection Alarm Clock on a desk with a remote temperature sensor mounted outside a door

Figure 2: The alarm clock on a desk, with a remote temperature sensor visible mounted on a wall outside a door, indicating its outdoor placement.

  1. Install 2 fresh AAA batteries (not included) into the remote temperature sensor.
  2. Place the remote sensor outdoors in a shaded, dry location, protected from direct sunlight and precipitation. Ensure it is within range of the main clock unit (typically up to 300 feet line of sight).
  3. The main clock unit should automatically detect and display the outdoor temperature. If not, press and hold the "CHANNEL" button (if available, or a similar button) on the main unit to initiate a search for the sensor.

4. Projection Setup

La Crosse Technology Atomic Projection Alarm Clock projecting time onto a wall

Figure 3: The alarm clock projecting the time "12:34" in red digits onto a wall, demonstrating its projection feature.

Operating Instructions

1. Setting Time and Date Manually

If atomic time synchronization is not desired or unavailable:

  1. Press and hold the "CALENDAR" button for 3 seconds to enter time setting mode.
  2. Use the "+" or "-" buttons (often shared with other functions) to adjust the flashing value (e.g., hour, minute, year, month, day).
  3. Press "CALENDAR" again to confirm the setting and move to the next value.
  4. Repeat until all settings are complete.

2. Setting the Alarm

  1. Press and hold the "ALARM" button for 3 seconds. The alarm time will flash.
  2. Use the "+" or "-" buttons to adjust the hour.
  3. Press "ALARM" to confirm the hour and move to minutes.
  4. Use the "+" or "-" buttons to adjust the minutes.
  5. Press "ALARM" to confirm and exit alarm setting mode.
  6. To activate/deactivate the alarm, press the "ALARM" button once. An alarm icon will appear/disappear on the display.

3. Snooze and Backlight Function

Top view of La Crosse Technology Atomic Projection Alarm Clock showing snooze and light button

Figure 4: Top view of the alarm clock, highlighting the "SNOOZE | LIGHT" button for temporary alarm silencing and display illumination.

4. Display Brightness (Auto Dim)

The clock features an auto-dim function (indicated by "AUTO DIM" on the display) which adjusts the display brightness based on ambient light conditions. This feature is typically automatic and cannot be manually adjusted.

5. Temperature Display

The clock displays both indoor and outdoor temperatures. The outdoor temperature is received from the remote sensor. You may be able to switch between Celsius and Fahrenheit by pressing a dedicated button (often labeled "C/F" or shared with another function).

Maintenance

Troubleshooting

ProblemSolution
No display or dim displayEnsure the power adapter is securely plugged in. Check backup batteries. Adjust ambient light if auto-dim is active.
Atomic time not synchronizingMove the clock closer to a window. Ensure it is away from electronic interference. Allow up to 24 hours for synchronization. Manually set the time if necessary.
Outdoor temperature not displayedCheck batteries in the remote sensor. Ensure the sensor is within range and not obstructed. Re-sync the sensor by pressing the "CHANNEL" button on the main unit.
Projection is blurryRotate the focus ring on the projection lens to sharpen the image. Ensure the projection distance is appropriate.
Alarm not soundingEnsure the alarm is activated (alarm icon visible on display). Verify the alarm time is set correctly.

Specifications

Warranty Information

This La Crosse Technology product comes with a 1-year Limited Parts and Labor Warranty from the date of purchase. This warranty covers manufacturing defects in materials and workmanship. It does not cover damage caused by misuse, accident, unauthorized modifications, or improper installation.

Please retain your proof of purchase for warranty claims.

Support

For further assistance, technical support, or to inquire about replacement parts, please visit the official La Crosse Technology website or contact their customer service department.

Related Documents - Atomic Projection Alarm Clock

Preview La Crosse Technology 616-143 Atomic Projection Alarm Clock Quick Setup Guide
Comprehensive quick setup guide for the La Crosse Technology 616-143 Atomic Projection Alarm Clock. Learn how to install batteries, set time and date, configure alarms, understand projection features, and position the outdoor sensor for optimal performance.
Preview La Crosse Technology 616-146A Atomic Projection Alarm User Manual
This instruction manual provides detailed information on the La Crosse Technology 616-146A Atomic Projection Alarm, including features, setup, operation, specifications, and warranty.
Preview La Crosse Technology 616-146v4 Atomic Projection Alarm Clock Setup Guide
Comprehensive setup guide for the La Crosse Technology 616-146v4 Atomic Projection Alarm Clock, detailing power-up, time setting, alarm functions, and troubleshooting for indoor/outdoor temperature monitoring.
Preview La Crosse Technology WT-5220U-ITV2 Atomic Projection Alarm Clock User Manual
User manual for the La Crosse Technology WT-5220U-ITV2 Atomic Projection Alarm Clock with indoor and outdoor temperature. Learn about setup, settings, features, specifications, and maintenance.
Preview La Crosse Technology Atomic Projection Clock 616-1410B/616-41667 Setup Guide
This setup guide provides instructions for the La Crosse Technology Atomic Projection Clock (models 616-1410B and 616-41667). It covers power up, atomic time synchronization, settings menu configuration, backlight and auto-dim features, projection options, alarm setup, snooze function, temperature trend interpretation, troubleshooting outdoor temperature readings, and care/maintenance. Includes specifications, warranty information, and FCC/Canada compliance statements.
Preview La Crosse 617-249v2 1.8" LED Atomic Clock: User Manual & Features
Get detailed instructions and specifications for the La Crosse 617-249v2 Atomic Curve LED Alarm Clock. Learn about power-up, atomic time signal, alarm settings, USB charging, and maintenance.