Introduction

The Akozon MPS-V-PLUS-3.5KW is a versatile pure sine wave inverter, solar charger, and battery charger, engineered to deliver uninterrupted power in a compact form factor. It integrates an MPPT solar charge controller for optimized battery performance and is compatible with both utility grid and generator power sources. This device is suitable for a wide range of applications, including solar cell roof installations, carport photovoltaic systems, RV solar power, and general household appliance use. Key safety features include overload protection, short-circuit protection, and a cold start function.

Setup

Safety Precautions

  • Ensure the inverter is installed in a well-ventilated area, away from flammable materials and moisture.
  • All electrical connections must be performed by qualified personnel in accordance with local electrical codes.
  • Before making any connections, ensure all power sources (AC, DC, Solar) are disconnected.
  • Wear appropriate personal protective equipment (PPE) during installation.

Installation Steps

  1. Mounting: Securely mount the inverter to a vertical surface using appropriate fasteners. Ensure adequate clearance for ventilation.
  2. Battery Connection: Connect the battery cables to the inverter's DC input terminals. Ensure correct polarity (+ to + and - to -).
  3. Solar Panel Connection: Connect the solar panel array to the PV input terminals. Verify correct polarity and ensure the solar input voltage is within the specified range.
  4. AC Input Connection: Connect the utility grid or generator AC power source to the AC input terminals.
  5. AC Output Connection: Connect your household or office loads to the AC output terminals.
  6. Communication Port: If desired, connect a communication cable to the COMM port for monitoring or remote control.
  7. Grounding: Ensure the inverter is properly grounded to prevent electrical hazards.
Full view of the Akozon MPS-V-PLUS-3.5KW inverter showing all connection points and the LCD display.

Figure 1: Overview of the Inverter with Connection Points.

Close-up of the COMM port on the Akozon MPS-V-PLUS-3.5KW inverter.

Figure 2: Communication (COMM) Port.

Close-up of the AC input/output terminals and cooling fan on the Akozon MPS-V-PLUS-3.5KW inverter.

Figure 3: AC Input/Output Terminals and Cooling Fan.

Operating Instructions

Powering On/Off

  • To Power On: After all connections are secure, switch the main power breaker to the ON position. The LCD display will illuminate.
  • To Power Off: Disconnect all AC loads, then switch the main power breaker to the OFF position. Disconnect solar and battery inputs if performing maintenance.
Close-up of the power switch on the Akozon MPS-V-PLUS-3.5KW inverter.

Figure 4: Power Switch.

LCD Display and Settings

The integrated LCD display provides real-time operational status and allows for easy adjustment of various parameters. Use the navigation buttons (UP, DOWN, ENTER, ESC) to browse menus and modify settings.

  • Battery Power Adjustment: Adjust the battery charging current and voltage limits to match your battery type and capacity.
  • Charger Priority: Set the priority for AC charger and solar charger. Options typically include:
    • Utility First: Prioritizes utility power for charging and loads.
    • Solar First: Prioritizes solar power for charging and loads.
    • SBU (Solar-Battery-Utility): Prioritizes solar, then battery, then utility.
Front panel of the Akozon MPS-V-PLUS-3.5KW inverter showing the LCD display and control buttons.

Figure 5: LCD Display and Control Panel.

Operating Modes

The inverter supports various operating modes to optimize power usage based on available sources:

  • Inverter Mode: Converts DC power from batteries or solar panels into AC power for connected loads.
  • AC Charger Mode: Charges connected batteries using utility grid power.
  • Solar Charger Mode: Charges connected batteries using solar panel power via the MPPT controller.
  • Hybrid Mode: Combines solar, battery, and utility power to provide continuous power and optimize energy consumption.
Diagrams illustrating inverter operation with and without battery, showing power flow from solar, generator, and mains supply to household appliances.

Figure 6: Operation Diagrams (Without Battery and With Battery).

Maintenance

Regular maintenance ensures the longevity and optimal performance of your inverter controller.

  • Cleaning: Periodically clean the exterior of the inverter with a dry, soft cloth. Ensure ventilation openings are free from dust and debris. Do not use liquid cleaners.
  • Connection Checks: Annually inspect all electrical connections (battery, solar, AC input/output) for tightness and signs of corrosion. Tighten any loose connections.
  • Battery Inspection: If using lead-acid batteries, check electrolyte levels and terminal cleanliness as per battery manufacturer guidelines.
  • Environmental Check: Ensure the installation environment remains within specified temperature and humidity ranges.
  • Firmware Updates: Check the manufacturer's website for any available firmware updates for improved performance or new features.

Important: Always disconnect all power sources before performing any maintenance or inspection.

Troubleshooting

This section provides solutions to common issues you might encounter.

ProblemPossible CauseSolution
Inverter not turning onNo DC input from battery; Main power switch off; Blown fuse/breakerCheck battery connections and voltage; Ensure power switch is ON; Check and reset/replace fuses/breakers.
No AC outputOverload; Short circuit; Low battery voltage; AC output breaker trippedReduce load; Check for short circuits in wiring; Charge battery; Reset AC output breaker.
Battery not chargingSolar panels not connected/producing power; AC input not present; Charging settings incorrectCheck solar panel connections and sunlight; Verify AC input power; Adjust charging settings via LCD.
Overload alarmConnected load exceeds inverter capacityDisconnect some loads to reduce total power consumption.
Short circuit alarmShort circuit detected on AC outputImmediately disconnect all loads and inspect wiring for short circuits.

If the problem persists after attempting these solutions, please contact customer support.

Technical Specifications (MPS-V-PLUS-3.5KW)

FeatureSpecification
Inverter Mode
Rated Power3500 W
DC Input24 VDC, 162 A
AC Output230 V CA, 50/60 Hz, 15.2 A, 1Φ
AC Mode
AC Input230 V CA, 50/60 Hz, 24.9 A, 1Φ
DC Output27 VDC max 80 A (30 A standard)
AC Output230 V CA, 50/60 Hz, 15.2 A, 1Φ
Solar Mode
Rated Power5000 W
Maximum Charger Current100 A
Rated Operating Voltage240 VDC
Maximum Solar Voltage500 VDC
MPPT Voltage Range120-450 VDC
MaterialCold rolled steel, PCB, Copper

Warranty and Support

For warranty information, technical support, or service inquiries, please refer to the product packaging or contact Akozon customer service directly. Keep your purchase receipt as proof of purchase for warranty claims.

© 2024 Akozon. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.