HEIMAN 2SA-633

HEIMAN Smoke Detector Instruction Manual

Model: 2SA-633

1. Product Overview

The HEIMAN Networked Radio Networkable Smoke Detector provides enhanced safety for your home. These intelligent devices communicate wirelessly with each other, ensuring that if one detector senses smoke, all interconnected units will sound an alarm. This feature provides an early warning system, even if the fire source is in a different room. Designed for ease of installation and long-term reliability, the detectors feature a 10-year battery life, minimizing maintenance. For comprehensive protection, it is recommended to install a networked smoke detector in every room, hallway, and on each floor of your property.

Multiple HEIMAN smoke detectors wirelessly interconnected, showing arrows indicating communication between units.

Image 1.1: Overview of HEIMAN networked smoke detectors demonstrating their wireless interconnection capability.

HEIMAN smoke detector installed on a ceiling in a home, with a father and child below, symbolizing safety.

Image 1.2: The HEIMAN smoke detector installed on a ceiling, providing safety in a home environment.

2. Key Features

3. Package Contents

Upon opening the package, please verify that all components are present and undamaged:

Box containing HEIMAN photoelectric smoke alarms, with one unit, screws, and a manual laid out beside it.

Image 3.1: Contents of the HEIMAN smoke detector package.

4. Setup and Installation

The HEIMAN smoke detector is designed for straightforward installation. Follow these steps for proper setup and interconnection:

4.1. Component Identification

Diagram of the HEIMAN smoke detector pointing out its components: Buzzer, Power/Test Mute Button, LED Indicator, Smoke Entrance, and the CR123A Lithium Battery.

Image 4.1: Key components of the HEIMAN smoke detector.

4.2. Mounting the Detector

Choose a suitable location for your smoke detector, typically on the ceiling in central areas, hallways, and bedrooms. Avoid placing near vents, windows, or in kitchens where cooking fumes might cause false alarms.

  1. Ensure the battery is correctly inserted. The detector should activate upon battery insertion.
  2. Using the provided screws and wall plugs, securely attach the mounting plate to the ceiling. Alternatively, use the adhesive pad for a tool-free installation on a clean, flat surface.
  3. Twist the smoke detector unit onto the mounting plate until it clicks into place.

4.3. Interconnecting Multiple Detectors

For a comprehensive safety network, interconnect all your HEIMAN smoke detectors. Up to 40 wireless alarms can be interconnected.

Diagram showing three HEIMAN smoke detectors with arrows indicating two-way wireless communication between them, illustrating their interconnection capability.

Image 4.2: Visual representation of interconnected smoke detectors.

  1. Designate a Host Device: Select one smoke detector to be the "Host" or "Master" unit. It is recommended to apply a distinguishing sticker (if provided) to this unit.
  2. Initiate Pairing on Host: On the designated Host device, press the central button three times quickly, then press and hold it once. The device will beep and its LED will flash, indicating it is in pairing mode.
  3. Pairing Secondary Devices: For each additional smoke detector you wish to interconnect, press its central button twice quickly, then press and hold it once. The device will beep and flash, confirming successful pairing with the Host.
  4. Repeat for All Units: Continue this process for all other detectors you want to include in the network. If pairing multiple devices, you may need to re-initiate pairing mode on the Host device after a short period (e.g., 1 minute) if it exits pairing mode.
  5. Verify Interconnection: After pairing all units, perform a test (see Section 5.1) to ensure all interconnected alarms sound when one is triggered.

Note: The pairing process can be sensitive to timing. If a device does not pair, repeat the steps carefully.

5. Operating Instructions

5.1. Testing the Alarm

It is crucial to test your smoke detectors regularly (e.g., monthly) to ensure they are functioning correctly.

5.2. Mute Function

The mute function allows you to temporarily silence the alarm in situations where non-emergency smoke (e.g., from cooking) might trigger it.

5.3. LED Indicator Status

The LED indicator provides visual feedback on the detector's status:

6. Maintenance

Regular maintenance ensures the optimal performance and longevity of your smoke detector.

Back of the HEIMAN photoelectric smoke alarm showing model number HM2SA-2W-T, power, frequency, maximum interconnectable quantity, and a warning about battery replacement after 10 years.

Image 6.1: Rear view of the smoke detector with product information and a reminder to replace after 10 years.

The barcode on the back of the device is 01012460070000023.

7. Troubleshooting

If you encounter issues with your HEIMAN smoke detector, refer to the following common problems and solutions:

ProblemPossible CauseSolution
Alarm chirps periodically.Low battery warning.The battery is designed to last 10 years and is not replaceable. The device has reached its end of life and needs to be replaced.
False alarms occur frequently.Dust accumulation, steam from bathroom, cooking fumes, or improper placement.Clean the detector as per Section 6. Relocate the detector if it's too close to kitchens or bathrooms. Use the mute function during cooking.
Detector does not respond to test button.Battery issue (if applicable for initial setup), or device malfunction.Ensure the battery is correctly inserted. If the device is old and chirping, it needs replacement. If new, contact support.
Interconnected units do not alarm together.Improper pairing or interference.Re-attempt the interconnection process as described in Section 4.3. Ensure all units are within range of each other.

8. Specifications

Detailed technical specifications for the HEIMAN Smoke Detector (Model 2SA-633):

AttributeDetail
Model Number2SA-633 (Part number: HM2SA-2W-T)
ManufacturerHEIMAN
Product Dimensions8.5 x 8.5 x 2.6 cm (3.385 x 3.385 x 1.024 inches)
Item Weight200 g
Power SourceBattery Powered (1 x CR123A Lithium Battery, included)
Battery LifeUp to 10 years (non-replaceable)
Sensor TypePhotoelectric
Alarm Sound Level85 dB
Operating Humidity≤95%
Upper Temperature Rating55 Degrees Celsius
MaterialABS plastic
ColorWhite
ConnectivityRadio Networkable (up to 40 units)
Diagram showing the dimensions of the HEIMAN smoke detector: 3.385 inches (86mm) in diameter and 1.024 inches (26mm) in height.

Image 8.1: Dimensions of the HEIMAN smoke detector.

9. Warranty and Support

For warranty information and technical support, please refer to the documentation provided with your purchase or contact the retailer or manufacturer directly. HEIMAN is the manufacturer of this product.

It is recommended to retain your proof of purchase for warranty claims.

Related Documents - 2SA-633

Preview Heiman 2SA-1-TY/5-TY Series Smoke Alarm User Manual
Comprehensive user manual for the Heiman 2SA-1-TY and 2SA-5-TY series photoelectric smoke alarms. Covers features, safety, installation, maintenance, troubleshooting, and networking. Available in English, German, French, Spanish, and Italian.
Preview Heiman Photoelectric Smoke Alarm User Manual: Installation, Operation, and Specifications
User manual for Heiman photoelectric smoke alarms, including models WS2SA-1, HS2SA-1, HM2SA-1W, WS2SA-5, HS2SA-5, and HM2SA-5W. This document provides essential information on installation, operation, technical specifications, maintenance, and alarm indications to ensure effective fire safety in homes.
Preview Heiman Fire Safety Products Catalogue - Smoke Alarms, CO Detectors, and More
Explore the comprehensive range of Heiman fire safety products, including smoke alarms, carbon monoxide detectors, heat alarms, smart gateways, remote controllers, and conventional fire alarm systems. Featuring advanced technology, certifications, and quality assurance.
Preview Heiman Photoelectric Smoke Alarm Device HM-633PHW, HM-635PHW User Manual
User manual for the Heiman Photoelectric Smoke Alarm Device, models HM-633PHW and HM-635PHW. This document provides instructions on installation, operation, maintenance, and troubleshooting for the smart photoelectric smoke alarm with RF transceiver capabilities.
Preview Photoelectric Smoke Alarm User Manual M419-9Ever1.2 - Heiman
User manual for the Heiman M419-9Ever1.2 photoelectric smoke alarm. Learn about product features, technical specifications, installation, troubleshooting, and maintenance for optimal fire safety.
Preview Inteligentny Czujnik Zalania Heiman WS2WL - Instrukcja Obsługi
Szczegółowa instrukcja obsługi inteligentnego czujnika zalania Heiman WS2WL. Dowiedz się, jak zainstalować, skonfigurować i używać czujnik do wykrywania wycieków wody w Twoim domu.