Introduction
This manual provides essential instructions for the safe and efficient operation, installation, and maintenance of your Migali C-2FB-HC Two Door Reach-In Freezer. Please read this manual thoroughly before operating the unit and retain it for future reference.

Front view of the Migali C-2FB-HC Two Door Reach-In Freezer, showcasing its stainless steel exterior and two doors.
Important Safety Information
Always follow basic safety precautions when using this appliance to reduce the risk of fire, electric shock, or injury.
- Ensure the unit is properly grounded.
- Do not store explosive substances such as aerosol cans with a flammable propellant in this appliance.
- Keep ventilation openings clear of obstruction.
- Do not use mechanical devices or other means to accelerate the defrosting process, other than those recommended by the manufacturer.
- Only qualified personnel should service the unit.
Setup and Installation
- Unpacking: Carefully remove all packaging materials. Inspect the unit for any shipping damage. Report any damage immediately to the carrier.
- Placement: Position the freezer on a level, sturdy surface. Ensure adequate clearance around the unit for proper ventilation (minimum 6 inches from walls). Avoid direct sunlight or heat sources.
- Leveling: The unit ships with wheels preinstalled. Ensure all wheels are locked to prevent movement. If necessary, adjust the leveling feet (if present) to ensure stability.
- Power Connection: Connect the freezer to a dedicated 115 Volt, 60 Hz, single-phase electrical outlet with a NEMA 5-15P plug. Do not use extension cords.
- Initial Startup: After plugging in, allow the unit to run for at least 2-4 hours before loading with products to ensure the interior reaches the desired temperature.

Side view of the Migali C-2FB-HC freezer, showing its compact design and pre-installed wheels for easy positioning.
Operating Instructions
Digital Temperature Controller
Your Migali C-2FB-HC freezer is equipped with a digital temperature controller for precise temperature management and display.

Close-up of the digital temperature controller, showing the display and control buttons.
- Power On/Off: Use the designated power switch (often green for ON, red for OFF) to power the unit.
- Temperature Display: The digital display shows the current internal temperature of the freezer.
- Setting Temperature: Refer to the specific controller manual (if provided separately) for detailed instructions on adjusting the set point. Generally, a "SET" button allows you to view and modify the desired temperature.
- Door Locks: The freezer is equipped with door locks for security. Use the provided key to lock or unlock the doors as needed.

Detail of the door lock mechanism, providing security for stored contents.
Maintenance
Cleaning
- Exterior: Clean the stainless steel exterior with a soft cloth and mild detergent. Avoid abrasive cleaners or scouring pads.
- Interior: Regularly clean the interior with a mild, food-safe cleaner. Remove shelves for thorough cleaning.
- Condenser Coil: The condenser coil should be cleaned regularly (every 30-90 days, depending on environment) to ensure efficient operation. Disconnect power before cleaning. Use a brush or vacuum cleaner to remove dust and debris.
- Door Gaskets: Inspect door gaskets for tears or damage. Clean them regularly to ensure a tight seal.
Automatic Defrost
This unit features an automatic defrost system, minimizing manual defrosting requirements. However, ensure proper air circulation inside the freezer to aid in efficient defrost cycles.

Interior view showing the fan and cooling element, crucial for robust forced air refrigeration and automatic defrost.
Shelving
The freezer includes 6 adjustable shelves. Ensure shelves are properly seated to support contents.

View of the adjustable shelving system within the freezer, designed for flexible storage.
Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| Freezer not cooling |
|
|
| Excessive frost buildup |
|
|
| Unit running constantly |
|
|
For issues not listed or if troubleshooting steps do not resolve the problem, please contact Migali customer support or a qualified service technician.
Specifications
| Model | C-2FB-HC |
| Brand | Migali |
| Capacity | 44.7 Cubic Feet |
| Dimensions (D x W x H) | 31.5" x 54.4" x 83.1" |
| Item Weight | 410 Pounds |
| Material Type | Stainless Steel (Interior and Exterior) |
| Number of Doors | 2 |
| Shelves | 6 |
| Defrost System | Automatic |
| Voltage | 115 Volts |
| Wattage | 989.00 |
| Refrigerant | R290 (Hydrocarbon) |
| Certification | ETL (Electrical, Sanitation) |
| Included Components | Power Cord with NEMA 5-15P Plug |
Warranty Information
Migali products typically come with a manufacturer's warranty. For specific details regarding the warranty period and coverage for your C-2FB-HC freezer, please refer to the warranty card included with your purchase or visit the official Migali website. Keep your proof of purchase for warranty claims.
- Compressor Warranty: Often 5 years.
- Parts & Labor Warranty: Often 2 years.
Note: Warranty terms may vary. Always consult the official documentation.
Customer Support
If you have any questions, require technical assistance, or need to schedule service, please contact Migali customer support.
- Migali Website: www.migali.com
- Contact Information: Refer to the Migali website or your product documentation for the most current contact details (phone, email).