1. Introduction

The CONTEC ABPM50 is a handheld ambulatory blood pressure monitor designed for continuous and dynamic blood pressure monitoring over a 24-hour period. Utilizing oscillography theory, this device provides an accurate basis for diagnosis by recording up to 350 groups of NIBP data in automatic mode and up to 300 groups in manual mode. Its compact and portable design, combined with a user-friendly interface and a high-definition color TFT display, ensures strong visibility and ease of use. The ABPM50 supports communication with a PC for data review, analysis, trend graph visualization, and report printing, making it a comprehensive tool for health monitoring.

CONTEC ABPM50 Blood Pressure Monitor showing a reading of 120/80 mmHg

Figure 1.1: Front view of the CONTEC ABPM50 monitor displaying blood pressure readings.

2. Package Contents

Upon unpacking, please verify that all components listed below are present and in good condition:

Contents of the CONTEC ABPM50 package including the monitor, cuff, cables, manual, and carrying pouch.

Figure 2.1: All included components of the ABPM50 system.

3. Initial Setup

3.1 Powering the Device

The ABPM50 is powered via a corded electric connection, typically through a USB cable for charging its internal battery. Connect the provided USB cable to the device and a suitable power source (e.g., a computer USB port or a USB wall adapter). Ensure the device is fully charged before initial use for optimal performance, especially for 24-hour monitoring.

3.2 Attaching the Blood Pressure Cuff

Connect the air tube from the blood pressure cuff securely to the air port on the side of the ABPM50 main unit. Ensure the connection is firm to prevent air leakage during measurement. The cuff is designed for adult, pediatric, and neonate use, with the included cuff being suitable for adults. Proper cuff placement is crucial for accurate readings. Position the cuff on the upper arm, ensuring the artery marker aligns with the brachial artery. The cuff should be snug but not overly tight, allowing two fingers to fit underneath.

4. Operating Instructions

4.1 Device Controls

The ABPM50 features a clear TFT display and intuitive buttons for navigation and operation:

Diagram showing the buttons on the CONTEC ABPM50 monitor with labels for left key, right key, middle button, enter OK, on/off, return back to main interface, and start/stop button.

Figure 4.1: ABPM50 button layout and functions.

4.2 Measurement Modes

The ABPM50 supports both automatic 24-hour monitoring and manual single measurements.

During measurement, remain still and avoid talking for accurate results. The device will automatically deflate the cuff once the measurement is complete.

5. PC Software Functionality

The CONTEC ABPM50 can connect to a PC via its USB interface to manage and analyze recorded data. The accompanying software provides comprehensive features for data interpretation:

Screenshot of the CONTEC ABPM50 software interface showing options for result analysis, trend chart observation, print report, and data review functions.

Figure 5.1: Overview of the PC software functions for the ABPM50.

Note: If the software CD is not included, please contact CONTEC customer support for download instructions or a direct download link. Some users have reported needing to contact support to obtain the software.

6. Maintenance and Care

6.1 Cleaning

To clean the ABPM50 main unit and cuff, use a soft, dry cloth. For stubborn dirt, a slightly damp cloth with mild soap can be used, followed by drying thoroughly. Do not use abrasive cleaners, solvents, or immerse the device in water. Ensure no liquid enters the device openings.

6.2 Storage

Store the device in a cool, dry place, away from direct sunlight, extreme temperatures, and high humidity. Use the provided carrying pouch to protect the device from dust and physical damage when not in use. Avoid placing heavy objects on the device.

7. Troubleshooting

This section addresses common issues you might encounter with your CONTEC ABPM50. If the problem persists, please contact customer support.

ProblemPossible Cause / Solution
Inaccurate ReadingsEnsure proper cuff placement and size. Remain still and quiet during measurement. Avoid caffeine, exercise, and smoking before measurement.
Device Not Powering OnCheck battery charge. Ensure USB cable is properly connected for charging. If the power button is unresponsive, contact support.
Cuff Does Not Inflate/Deflate ProperlyCheck for kinks or blockages in the air tube. Ensure the cuff is securely connected to the device. Verify the cuff is not damaged.
"No Data Found" Message After DownloadThis message may appear even if data was successfully downloaded. Verify data presence within the PC software. Re-attempt download if necessary.
Difficulty with PC Software Installation/UseEnsure your operating system is compatible. Temporarily disable antivirus/firewall if installation issues occur. Contact CONTEC support for software download links or technical assistance.
"PROMPT SOUND" Menu PasswordThe password for the "PROMPT SOUND" menu is 8015.

For issues not covered here, or if troubleshooting steps do not resolve the problem, please refer to the warranty and support section for contact information.

8. Technical Specifications

FeatureDetail
Model Namenew style ABPM50
Item Model NumberABPM50
Product Dimensions (L x W x Th)9.65" x 2.56" x 5.63"
Item Weight1.9 Pounds
BrandCONTEC
Power SourceCorded Electric
Display TypeTFT Color Display
Included ComponentsCable, Cuff
Age Range (Description)Adult, child
Measurement RangeAdult, Pediatric, Neonate (with appropriate cuffs)
Data Storage CapacityUp to 350 groups (automatic), 300 groups (manual)

9. Warranty and Support

9.1 Product Warranty

The CONTEC ABPM50 comes with a one-year warranty from the date of purchase. CONTEC is committed to taking full responsibility for any quality problems that may arise within this one-year period. This warranty covers defects in materials and workmanship under normal use.

9.2 Customer Support

For any questions, technical assistance, troubleshooting beyond this manual, or warranty claims, please contact CONTEC customer support. When contacting support, please have your product model number (ABPM50) and purchase details ready to facilitate faster service. You can typically find contact information on the CONTEC official website or through your point of purchase.

Note: Statements regarding dietary supplements have not been evaluated by the FDA and are not intended to diagnose, treat, cure, or prevent any disease or health condition. This device is intended for monitoring purposes.

Related Documents - ABPM50

Preview CONTEC08C Electronic Sphygmomanometer User Manual
User manual for the CONTEC08C Electronic Sphygmomanometer, detailing its functions, safety precautions, operation, maintenance, and specifications for accurate blood pressure measurement.
Preview Contec CMS1600B Color Doppler Ultrasound Diagnostic System User Manual
This user manual provides comprehensive instructions for the Contec CMS1600B, a wireless handheld color Doppler ultrasound diagnostic system. It covers device operation, software functions, safety precautions, maintenance, and troubleshooting for healthcare professionals.
Preview Contec SP80B Spirometer User Manual and Technical Guide
Comprehensive user manual for the Contec SP80B Spirometer, detailing operation, safety guidelines, technical specifications, maintenance, and troubleshooting for lung function testing.
Preview CONTEC ESB0059 Pulse Oximeter Probe User Manual
User manual for the CONTEC ESB0059 Pulse Oximeter Probe, detailing its intended use, performance specifications, directions for use, maintenance, warnings, and electromagnetic compatibility information for healthcare professionals.
Preview Contec CMS50D1 Fingertip Pulse Oximeter User Manual and Specifications
Comprehensive user guide for the Contec CMS50D1 fingertip pulse oximeter, detailing its features, operation, maintenance, troubleshooting, and technical specifications for SpO2 and pulse rate monitoring.
Preview RT-200 Universal Cable + TV Remote Control Programming and Operating Instructions
Comprehensive programming and operating instructions for the Contec RT-200 Universal Cable and TV Remote Control. Learn how to install batteries, program for cable set-top boxes and TVs using code entry or point-and-press methods, manage volume and input, and troubleshoot common issues. Includes extensive TV setup codes for various brands.