1. Introduction
The CONTEC ABPM50 is a handheld ambulatory blood pressure monitor designed for continuous and dynamic blood pressure monitoring over a 24-hour period. Utilizing oscillography theory, this device provides an accurate basis for diagnosis by recording up to 350 groups of NIBP data in automatic mode and up to 300 groups in manual mode. Its compact and portable design, combined with a user-friendly interface and a high-definition color TFT display, ensures strong visibility and ease of use. The ABPM50 supports communication with a PC for data review, analysis, trend graph visualization, and report printing, making it a comprehensive tool for health monitoring.

Figure 1.1: Front view of the CONTEC ABPM50 monitor displaying blood pressure readings.
2. Package Contents
Upon unpacking, please verify that all components listed below are present and in good condition:
- CONTEC ABPM50 Main Unit
- Adult Blood Pressure Cuff
- USB Communication Cable
- User Manual
- Carrying Pouch
- Software CD (or download instructions)

Figure 2.1: All included components of the ABPM50 system.
3. Initial Setup
3.1 Powering the Device
The ABPM50 is powered via a corded electric connection, typically through a USB cable for charging its internal battery. Connect the provided USB cable to the device and a suitable power source (e.g., a computer USB port or a USB wall adapter). Ensure the device is fully charged before initial use for optimal performance, especially for 24-hour monitoring.
3.2 Attaching the Blood Pressure Cuff
Connect the air tube from the blood pressure cuff securely to the air port on the side of the ABPM50 main unit. Ensure the connection is firm to prevent air leakage during measurement. The cuff is designed for adult, pediatric, and neonate use, with the included cuff being suitable for adults. Proper cuff placement is crucial for accurate readings. Position the cuff on the upper arm, ensuring the artery marker aligns with the brachial artery. The cuff should be snug but not overly tight, allowing two fingers to fit underneath.
4. Operating Instructions
4.1 Device Controls
The ABPM50 features a clear TFT display and intuitive buttons for navigation and operation:

Figure 4.1: ABPM50 button layout and functions.
- Left Key (on screen): Used for navigating menus or decreasing values.
- Right Key (on screen): Used for navigating menus or increasing values.
- Middle Button (on screen): Typically for menu access or selection.
- Enter OK: Confirms selections.
- On/Off: Powers the device on or off.
- Return to Main Interface: Navigates back to the main display.
- Start/Stop Button: Initiates or stops a blood pressure measurement.
4.2 Measurement Modes
The ABPM50 supports both automatic 24-hour monitoring and manual single measurements.
- Automatic (24-hour) Monitoring: This mode allows for continuous blood pressure recording over a 24-hour period. The device can record up to 350 groups of NIBP data. Before starting, ensure the device is fully charged and the cuff is correctly positioned. Configure the measurement intervals through the device's menu or via the PC software. Press the Start/Stop button to begin the 24-hour monitoring session.
- Manual Measurement: For a single, on-demand blood pressure reading, ensure the cuff is properly applied. Press the Start/Stop button to initiate a measurement. The device will inflate the cuff, take the reading, and display the results. Up to 300 groups of data can be recorded manually.
During measurement, remain still and avoid talking for accurate results. The device will automatically deflate the cuff once the measurement is complete.
5. PC Software Functionality
The CONTEC ABPM50 can connect to a PC via its USB interface to manage and analyze recorded data. The accompanying software provides comprehensive features for data interpretation:
- Data Download: Transfer NIBP measurement results from the device to your computer.
- Data Review and Analysis: View and analyze measured results, including scoop-shape trend graphs, filling-type trend graphs, histograms, pie charts, and correlation line graphs.
- Report Printing: Generate and print detailed reports of your blood pressure data.
- Data Editing: Edit individual NIBP data entries and add annotations for personalized tracking.
- Information Management: Edit basic patient information, doctor's advice, NIBP status instructions, and current medication information.

Figure 5.1: Overview of the PC software functions for the ABPM50.
Note: If the software CD is not included, please contact CONTEC customer support for download instructions or a direct download link. Some users have reported needing to contact support to obtain the software.
6. Maintenance and Care
6.1 Cleaning
To clean the ABPM50 main unit and cuff, use a soft, dry cloth. For stubborn dirt, a slightly damp cloth with mild soap can be used, followed by drying thoroughly. Do not use abrasive cleaners, solvents, or immerse the device in water. Ensure no liquid enters the device openings.
6.2 Storage
Store the device in a cool, dry place, away from direct sunlight, extreme temperatures, and high humidity. Use the provided carrying pouch to protect the device from dust and physical damage when not in use. Avoid placing heavy objects on the device.
7. Troubleshooting
This section addresses common issues you might encounter with your CONTEC ABPM50. If the problem persists, please contact customer support.
| Problem | Possible Cause / Solution |
|---|---|
| Inaccurate Readings | Ensure proper cuff placement and size. Remain still and quiet during measurement. Avoid caffeine, exercise, and smoking before measurement. |
| Device Not Powering On | Check battery charge. Ensure USB cable is properly connected for charging. If the power button is unresponsive, contact support. |
| Cuff Does Not Inflate/Deflate Properly | Check for kinks or blockages in the air tube. Ensure the cuff is securely connected to the device. Verify the cuff is not damaged. |
| "No Data Found" Message After Download | This message may appear even if data was successfully downloaded. Verify data presence within the PC software. Re-attempt download if necessary. |
| Difficulty with PC Software Installation/Use | Ensure your operating system is compatible. Temporarily disable antivirus/firewall if installation issues occur. Contact CONTEC support for software download links or technical assistance. |
| "PROMPT SOUND" Menu Password | The password for the "PROMPT SOUND" menu is 8015. |
For issues not covered here, or if troubleshooting steps do not resolve the problem, please refer to the warranty and support section for contact information.
8. Technical Specifications
| Feature | Detail |
|---|---|
| Model Name | new style ABPM50 |
| Item Model Number | ABPM50 |
| Product Dimensions (L x W x Th) | 9.65" x 2.56" x 5.63" |
| Item Weight | 1.9 Pounds |
| Brand | CONTEC |
| Power Source | Corded Electric |
| Display Type | TFT Color Display |
| Included Components | Cable, Cuff |
| Age Range (Description) | Adult, child |
| Measurement Range | Adult, Pediatric, Neonate (with appropriate cuffs) |
| Data Storage Capacity | Up to 350 groups (automatic), 300 groups (manual) |
9. Warranty and Support
9.1 Product Warranty
The CONTEC ABPM50 comes with a one-year warranty from the date of purchase. CONTEC is committed to taking full responsibility for any quality problems that may arise within this one-year period. This warranty covers defects in materials and workmanship under normal use.
9.2 Customer Support
For any questions, technical assistance, troubleshooting beyond this manual, or warranty claims, please contact CONTEC customer support. When contacting support, please have your product model number (ABPM50) and purchase details ready to facilitate faster service. You can typically find contact information on the CONTEC official website or through your point of purchase.