1. Introduction
This manual provides detailed instructions for the safe installation, operation, and maintenance of your Walrusled 2FT LED Vapor Tight Emergency Light. Please read this manual thoroughly before installation and use, and retain it for future reference.
2. Safety Information
WARNING: Risk of electric shock. Turn off power before installation or servicing.
- Installation should be performed by a qualified electrician in accordance with national and local electrical codes.
- Ensure the supply voltage is compatible with the fixture (100-277V AC).
- Do not handle the fixture with wet hands or when standing on wet surfaces.
- Do not modify the fixture or its components.
- Keep flammable materials away from the light fixture.
- Operating temperature range: -4°F to 104°F (-20°C to 40°C).
3. Product Features
- Emergency Battery Backup: Integrated LiFePO4 6.4V/3000mAh battery provides over 200 minutes of emergency illumination at 5W output. Automatic charging and discharging.
- Test Button & Indicators: Features a built-in test button for emergency function verification and indicator lights for battery status (Green: full charged, Red: charging, Yellow: self-test fault).
- Durable Construction: Non-corrosive polycarbonate (PC) housing with IP65 waterproof and dustproof rating, and IK08 impact resistance. Designed to withstand moisture, dust, and extreme temperatures.
- Selectable Wattage: Adjustable between 10W (1250lm) and 20W (2500lm) to suit various lighting requirements.
- Selectable Color Temperature (CCT): Offers three color temperature options: 3000K (Warm White), 4000K (Sunrise White), and 5000K (Noon White).
- Certifications: CE, FCC, SAA, and UKCA certified for safety and reliability.


4. Package Contents
Verify that all components are present before beginning installation:
- 1 x Walrusled 2FT LED Vapor Tight Emergency Light Fixture
- Mounting Hardware (screws, anchors, clips, hanging ropes)
- Instruction Manual
5. Technical Specifications
| Specification | Value |
|---|---|
| Brand | Walrusled |
| Model Name | ZL-PSBLP18-2FT-CE-CCT |
| Product Dimensions | 27.16"L x 4.72"W x 3.93"H |
| Item Weight | 4.02 Pounds |
| Material | Aluminum, Polycarbonate, Stainless Steel |
| Power Source | Corded Electric, Battery Powered |
| Voltage | 100-277 Volts (AC) |
| Wattage | 10W / 20W (Selectable) |
| Brightness | 1250lm (10W) / 2500lm (20W) |
| Light Color / CCT | 3000K, 4000K, 5000K (Selectable) |
| Emergency Output | 5W |
| Battery Type | LiFePO4 6.4V/3000mAh |
| Emergency Duration | Over 200 minutes |
| Charging Time | 16 to 24 hours |
| Water Resistance Level | IP65 (Waterproof) |
| Impact Resistance | IK08 |
| Indoor/Outdoor Usage | Indoor, Outdoor |
| Mounting Type | Flushmount, Surface Mount, Hanging Mount |
| Certifications | CE, FCC, SAA, UKCA |
6. Installation Instructions
6.1. Before You Begin
- Ensure power is disconnected at the circuit breaker before starting installation.
- Wear appropriate personal protective equipment.
- Review all steps before proceeding.
6.2. Wiring Methods
The fixture supports two wiring methods for emergency functionality:
- Method 1 (L(UA) Wiring): Divide the L(UA) wiring into two wires. Connect one wire to the SA terminal through the switch. The light fixture will be controlled by an external wall switch.
- Method 2 (Short-circuit L and SA): Short-circuit L and SA with a short wire. The light fixture will be 7 x 24h ON.

6.3. CCT and Wattage Selection
Before closing the fixture, locate the internal switches for CCT (Color Temperature) and Wattage selection. Adjust these switches to your desired settings:
- CCT Switch: Select 3000K, 4000K, or 5000K.
- Wattage Switch: Select 10W or 20W.

6.4. Mounting Options
The fixture supports both surface mount and suspend mount installations.

6.4.1. Surface Mount Installation
- Open the buckle and take out the diffuser.
- Remove the aircraft buckles at both ends to take out the iron plate. Connect the earth wire to the iron plate and connect the earth wire from the power supply plug-in terminal block.
- Drill holes on the ceiling in the corresponding position according to the holes of the iron plate bracket. Insert M6 wall plugs into the holes, then fix the iron plate bracket to the ceiling with the provided M6 screws.
- Pull the power cable into the luminaire from the PG13.5 waterproof gland.
- Connect the power cable to the terminal block on the luminaire bracket according to the wiring sequence.
- Connect the luminaire body with the slings (which are pre-fixed), connect the earth wire plug to the earth wire from the power supply, and insert the connector on the control gear.
- Install the iron plate back to the bracket, rotate the aircraft buckles on both ends of the bracket to lock the iron plate, install the diffuser onto the bracket, and fasten the buckles.
6.4.2. Suspend Mount Installation
- Separate the luminaire body from the luminaire bracket (refer to Step 1 of Surface Mount).
- Drill holes on the ceiling in the corresponding position according to the holes position of the hanging rope. Insert M6 wall plugs into the holes, then fix the hanging rope clip to the ceiling with the provided M6 screws.
- Install the installation buckles onto the hanging rope with provided M4 flat screws.
- Pull the power cable into the luminaire bracket from the cable entry hole, then install the bracket onto the buckles.
- Refer to steps 4, 5, and 6 of Surface Mount for wiring and final assembly.
7. Operating Instructions
7.1. Emergency Battery Backup Function
The built-in LiFePO4 battery automatically charges when main power is supplied and discharges to provide emergency lighting when main power is interrupted. The battery provides over 200 minutes of illumination.
7.2. Test Button Functions
The integrated test button allows for verification and management of the emergency function:
- Simulated Emergency Testing: Press and hold the test button for more than 1.5 seconds. The luminaire will simulate a main power failure and enter emergency mode. Release the button to return to the previous status.
- Force Self-test: Press and hold the test button for more than 10 seconds. The luminaire will perform a self-test. Release the button to return to the previous status until the self-test is finished. The self-test result will be indicated by the Yellow indicator.
- Reset to Default Setting: Press the test button 3 times within 3 seconds. All three indicators will flash 3 times synchronously, and the luminaire will enter the default setting mode. Yellow and Red indicators will flash synchronously.
7.3. Indicator Lights
The fixture features three indicator lights:
- Green LED: Indicates the battery is fully charged.
- Red LED: Indicates the battery is currently charging.
- Yellow LED: Indicates a self-test fault or other system error.

8. Maintenance
Regular maintenance ensures optimal performance and longevity of your light fixture.
- Cleaning: Clean the exterior of the fixture periodically with a soft, damp cloth. Do not use abrasive cleaners or solvents. Ensure the fixture is off and cool before cleaning.
- Battery Check: Perform monthly checks of the emergency function using the test button to ensure the battery is operational.
- Visual Inspection: Periodically inspect the fixture for any signs of damage, loose connections, or wear.
- Battery Replacement: The LiFePO4 battery has a lifespan of more than 3 years. If the emergency duration significantly decreases, consider replacing the battery by a qualified technician.
9. Troubleshooting
If you encounter issues with your Walrusled LED Vapor Tight Emergency Light, refer to the following table for common problems and solutions.
| Problem | Possible Cause | Solution |
|---|---|---|
| Fixture does not turn on. | No power supply; Incorrect wiring; Faulty fixture. | Check circuit breaker and power connections. Verify wiring according to instructions. Contact customer support if problem persists. |
| Emergency function not working or short duration. | Battery not charged; Battery faulty or at end of life; Incorrect emergency wiring. | Ensure fixture has been connected to power for at least 24 hours to fully charge the battery. Perform a self-test. Check emergency wiring. If battery is old, consider replacement. |
| Incorrect CCT or Wattage output. | Switches set incorrectly. | Turn off power. Open the fixture and adjust the internal CCT and Wattage selection switches to the desired settings. Reassemble and restore power. |
| Yellow indicator light is on. | Self-test fault indication. | Perform a Force Self-test. If the yellow light remains, there may be an internal fault. Contact customer support. |
10. Warranty and Customer Support
Walrusled provides a one-year limited warranty for this product, covering defects in materials and workmanship under normal use. Additionally, we offer 5-year technical support to ensure your satisfaction.
For warranty claims, technical assistance, or any questions regarding your Walrusled 2FT LED Vapor Tight Emergency Light, please contact Walrusled customer support through your purchase platform or visit the official Walrusled website.
Please have your model number (ZL-PSBLP18-2FT-CE-CCT) and proof of purchase ready when contacting support.