Introduction
This manual provides detailed instructions for the safe and effective operation of your Irfora Color Temperature Tester, model SK-8201. This device is designed for precise measurement of illuminance and color temperature, making it suitable for various professional and home lighting assessment needs.
Please read this manual thoroughly before using the device and keep it for future reference.
Product Overview
The Irfora SK-8201 is a high-precision illuminance meter capable of measuring brightness and color temperature. It features a responsive digital probe for fast readings and a multi-screen display for concurrent information presentation.

Figure 1: Front view of the Irfora SK-8201 Color Temperature Tester, showing the display and control buttons.

Figure 2: Irfora SK-8201 model highlighting its key features and specifications, including illuminance and color temperature measurement ranges.
Key Features:
- Illuminance measurement range: 0.5-300000 LUX
- Color temperature (CCT) range: 2500K-8000K
- Fast sampling rate: 4 times/second
- Data HOLD function
- LUX/FC unit conversion
- Automatic shutdown for power saving
- Multi-screen display for simultaneous readings

Figure 3: Visual representation of the nine core advantages of the Irfora SK-8201, including data retention, unit conversion, and automatic shutdown.
Setup
1. Battery Installation
The SK-8201 requires two 1.5V AAA batteries (not included). Follow these steps to install them:
- Locate the battery compartment on the back of the device.
- Slide open the battery cover.
- Insert two AAA batteries, ensuring correct polarity (+/-).
- Close the battery cover securely.
2. Initial Power On
Press the power button (⑂) located at the bottom left of the device to turn it on. The display will illuminate, showing current readings.
Operating Instructions
1. Understanding the Display and Buttons

Figure 4: Diagram illustrating the functional parameters and display areas of the Irfora SK-8201 (similar to SK-8202), including sensor head, illumination display, color temperature display, power supply, and data holding/unit switching buttons.
- Sensor Head: Located at the top, this is the light-sensitive component. Ensure it is clean and unobstructed for accurate readings.
- Illumination Display Area: Shows the current illuminance in LUX or FC.
- Color Temperature Display Area: Shows the current color temperature in Kelvin (K).
- Power Button (⑂): Turns the device on/off.
- HOLD/UNIT Button: Press once to hold the current reading. Press and hold to switch between LUX and FC units.
2. Taking Measurements
- Turn on the device by pressing the power button.
- Position the sensor head towards the light source you wish to measure. Ensure no shadows or obstructions are cast on the sensor.
- The device will automatically display the illuminance (LUX/FC) and color temperature (K) readings.
- To hold the current reading on the display, press the HOLD/UNIT button once. Press it again to release the hold and resume live readings.
- To switch between LUX and FC units, press and hold the HOLD/UNIT button until the unit changes on the display.

Figure 5: The Irfora SK-8201 held in hand, demonstrating its compact size and clear digital display during operation.
3. Automatic Shutdown
The device features an automatic shutdown function to conserve battery life. If no button is pressed for a certain period (typically 15 minutes), the device will automatically power off. Press the power button to turn it back on.
Maintenance
- Cleaning: Use a soft, dry cloth to clean the device. Do not use abrasive cleaners or solvents. Ensure the sensor head is free of dust and smudges.
- Storage: When not in use for extended periods, remove the batteries to prevent leakage and store the device in a cool, dry place, away from direct sunlight and extreme temperatures.
- Battery Replacement: Replace batteries when the low battery indicator appears on the display to ensure accurate readings.
- Avoid Impact: Handle the device with care to prevent damage from drops or impacts.
Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| Device does not turn on. | Batteries are dead or incorrectly installed. | Check battery polarity or replace with new AAA batteries. |
| Inaccurate readings. | Sensor head is dirty or obstructed; low battery. | Clean the sensor head. Replace batteries if low. Ensure no shadows are cast on the sensor. |
| Display is blank or flickering. | Low battery; device malfunction. | Replace batteries. If problem persists, contact customer support. |
Specifications
| Parameter | Value |
|---|---|
| Model | SK-8201 |
| Illuminance Measurement Range | 0.5-300000 LUX |
| Maximum Display | 99999 |
| Resolution (<10000 LUX) | 0.1 |
| Resolution (>10000 LUX) | 1 |
| Illumination Accuracy | ±(4%+10) |
| Illuminance Repeat Test | ±2% |
| Color Temperature CCT | 2500K-8000K (±5%) |
| Sampling Rate | 4 times/second |
| Angle of Incidence | 100 degrees |
| Spectral Range | 400nm-700nm |
| Operating Temperature | 0-45℃ (±2℃) |
| Environment | -10℃ to 50℃, max 80%RH, altitude <2000m |
| Power Supply | 2 * 1.5V AAA battery (not included) |
| Item Size | 100 * 55 * 26mm / 3.94 * 2.17 * 1.02in |
| Item Weight | 70g / 2.47ounce |
Warranty and Support
For warranty information and technical support, please refer to the contact details provided with your purchase or visit the official Irfora website. Keep your purchase receipt as proof of purchase for warranty claims.
If you encounter any issues not covered in the troubleshooting section, please contact our customer service team for assistance.