1. Introduction
The PEAKMETER PM6816 is a versatile digital instrument designed for network and telecommunication professionals. It combines the functions of a network cable tester and a wire tracker, enabling efficient identification, tracing, and testing of various cable types including RJ11, RJ45, Cat5, Cat6, Ethernet, LAN, and BNC coaxial cables. This manual provides detailed instructions for the safe and effective use of your PM6816 device.
2. Safety Information
Please read and understand all safety warnings and operating instructions before using this product. Failure to do so may result in injury or damage to the device.
- Do not operate the device if it appears damaged.
- Ensure batteries are correctly installed before use.
- Avoid testing live circuits with the wire tracking function unless specifically designed for it and appropriate safety measures are taken.
- Keep the device away from water and extreme temperatures.
- This device is rated CE CAT. III 600V RoHS compliant. Adhere to all relevant electrical safety standards.
3. Package Contents
Verify that all items are present in your package:
- PM6816 Emitter (Main Unit)
- PM6816 Receiver (Probe)
- Earphone cable x 1
- Gift Box x 1
- Plastic Bag x 1
- Manual x 1
- Battery (PPPVC9VE012/9V) x 1 (for Receiver)
- Battery (AA/1.5V Manganese Battery) x 3 (for Emitter)
- RJ45 to Alligator Clip Cable x 1
- RJ11 to RJ11 Cable x 1
- RJ45 to RJ45 Cable x 1
4. Product Overview
The PM6816 consists of two main components: the Emitter (main unit) and the Receiver (probe). Familiarize yourself with the controls and ports.

Figure 1: Front view of the PM6816 Emitter (Main Unit). This unit features LED indicators for various cable test results (SHORT, REVERSED, MISWIRE, SPLIT PAIRS), a 'TEST' button, and switches for 'CONT' (Continuity) and 'SCAN' (Wire Tracking) modes, along with ON/OFF and Hz/dB buttons.

Figure 2: The PM6816 Emitter and Receiver (Probe). The probe is used to detect the signal emitted by the main unit for wire tracing.

Figure 3: Back view of the PM6816 Emitter with the battery compartment open, showing slots for three AA batteries.
5. Setup
5.1 Battery Installation
- Open the battery compartment cover on the back of the Emitter unit (Figure 3).
- Insert three 1.5V AA batteries, observing the correct polarity.
- Close the battery compartment cover securely.
- For the Receiver probe, open its battery compartment and insert one 9V battery, observing the correct polarity.
- Close the Receiver's battery compartment cover securely.
5.2 Initial Connection
Before performing any tests, ensure the device is powered on using the ON/OFF switch on both the Emitter and Receiver units.
6. Operating Instructions
6.1 Wire Tracking (Cable Tracing)
This function helps locate a specific cable among a bundle or trace its path.
- Connect the cable to be traced to the appropriate port on the Emitter unit (e.g., RJ45, RJ11, or use the alligator clips for bare wires).
- Switch the Emitter to 'SCAN' mode.
- Turn on the Receiver probe.
- Adjust the sensitivity knob on the Receiver.
- Move the tip of the Receiver along the suspected cable path. The Receiver will emit an audible tone when it detects the signal from the Emitter, indicating the presence of the traced cable.
- The tone will be loudest when directly over the cable.
Video 1: Demonstration of the PEAKMETER PM6816 Network Cable Tester's wire tracking function. The video shows how to connect a network cable to the emitter and use the receiver probe to detect the signal along the cable, indicating its location.
6.2 Cable Continuity Testing
This function checks for open circuits, short circuits, miswires, reversed pairs, and split pairs in network and telephone cables.
- Connect one end of the cable to the appropriate port on the Emitter unit (e.g., RJ45, RJ11).
- Connect the other end of the cable to the corresponding port on the Receiver unit.
- Switch the Emitter to 'CONT' mode.
- Press the 'TEST' button on the Emitter.
- Observe the LED indicators on the Emitter. They will light up sequentially, indicating the status of each wire pair.
- Specific LED patterns indicate different fault conditions (e.g., 'SHORT', 'MISWIRE', 'REVERSED', 'SPLIT PAIRS'). Refer to the Emitter's display for detailed fault identification.
6.3 Telephone Line Test
Identify the state of a working telephone line.
- Connect the telephone line to the RJ11 port on the Emitter.
- The Emitter can identify the line status (e.g., clear, ringing, busy).
6.4 Switch Port Collation
Detect the connected condition of a switch port.
- Connect the Emitter to a switch port.
- The device can indicate if the port is active and connected.
6.5 DC Level Test
Test line level, positive, and negative polarity.
- Use the appropriate connection (e.g., alligator clips) to test DC voltage levels and polarity.
7. Features
The PEAKMETER PM6816 offers a range of features for comprehensive cable testing:
- Multi-function network cable tester and wire tracker.
- Tests RJ11, RJ45, Cat5, Cat6, Telephone, Ethernet, LAN, and BNC coaxial cables.
- Wire tracking with audible tone for easy identification.
- Continuity testing for open circuit, short circuit, miswire, reverse connection, and split pairs.
- Telephone line status identification (clear, ring, busy).
- Switch port connection detection.
- DC level and polarity testing.
- Includes headphones for use in noisy environments.
8. Specifications

Figure 4: PM6816 Main Functions and General Specifications.
| Function | Description |
|---|---|
| Wire Track | Directly track wire type: RJ45, RJ11. Track other wire through the attachment. |
| Sequence Collation | Open circuit, short circuit, detection of cable line sequence. |
| Network Wire Collation | Fully test the line sequence of network cable, open circuit, short-circuit, miswire, reverse connection and split pairs. |
| Telephone Line Test | Identify the state of working telephone line (clear, ring, busy). |
| Continuity | Judge continuity of the cables or wires. |
| Switch Port Collation | Detection switch connected condition. |
| DC Level Test | Test line level, positive and negative polarity. |
| Parameter | Value |
|---|---|
| Power Supply (Emitter) | 3*1.5V AA Batteries |
| Power Supply (Receiver) | 1*9V 6F22 Battery |
| Emitter Dimensions | 122mm x 66mm x 28mm (4.8 x 2.6 x 1.1 inches) |
| Receiver Dimensions | 210mm x 44mm x 25mm (8.3 x 1.7 x 1.0 inches) |
| Net Weight (Emitter) | 99g |
| Net Weight (Receiver) | 81.8g (None of the batteries) |
| Gross Weight | 449g (0.99 lbs) |
| Safety Rating | CE CAT. III 600V RoHS |
| Product Dimensions | 5.91 x 3.94 x 7.09 inches; 2.2 Pounds (packaged) |
| Item Model Number | EC-PM6816 |
| Color | Orange |
9. Maintenance
- Clean the device with a soft, dry cloth. Do not use abrasive cleaners or solvents.
- Remove batteries if the device will not be used for an extended period to prevent leakage.
- Store the device in a cool, dry place, away from direct sunlight.
- Regularly check cables and connectors for wear and tear.
10. Troubleshooting
- No Power: Check battery installation and ensure batteries are not depleted. Replace if necessary.
- No Signal during Wire Tracking: Ensure the Emitter is in 'SCAN' mode and the Receiver is turned on with adequate sensitivity. Verify the cable is properly connected to the Emitter.
- Inaccurate Continuity Test Results: Ensure all cable connections are secure and clean. Re-test the cable. If issues persist, the cable may be faulty.
- Weak or Intermittent Signal: Check battery levels in both units. Ensure there are no strong electromagnetic interference sources nearby.
11. Warranty and Support
For warranty information, technical support, or service inquiries, please contact your retailer or the manufacturer directly. Keep your purchase receipt as proof of purchase.