1. Introduction

This manual provides essential information for the safe and effective operation of your ANENG AN8002 TrueRMS Digital Multimeter. Please read this manual thoroughly before use and retain it for future reference. The AN8002 is designed to accurately measure AC/DC voltage, current, resistance, capacitance, frequency, duty cycle, diode, and temperature, making it suitable for various automotive and household electrical troubleshooting tasks.

ANENG AN8002 TrueRMS Digital Multimeter and accessories

Figure 1.1: The ANENG AN8002 Digital Multimeter along with its included test leads and accessories.

2. Safety Information

To ensure safe operation, always adhere to the following safety precautions. Failure to do so may result in electric shock, injury, or damage to the meter or equipment under test.

  • Always disconnect power to the circuit and discharge all high-voltage capacitors before testing resistance, continuity, diodes, or capacitance.
  • Do not apply more than the rated voltage, as marked on the meter, between the terminals or between any terminal and earth ground. The meter is designed for 550V high voltage protection.
  • Use extreme caution when working with voltages above 30V AC RMS, 42V peak, or 60V DC. These voltages pose a shock hazard.
  • Keep your fingers behind the probe barriers during measurements.
  • Replace the battery immediately when the low battery indicator appears to ensure accurate readings.
  • Do not operate the meter if it appears damaged or if the case is open.
  • Ensure the test leads are in good condition, without any damaged insulation.
  • Install fuses with the correct amp/volt ratings as shown in the manual to prevent damage or injury.
Hands holding ANENG AN8002 multimeter with test leads connected

Figure 2.1: Proper handling of the multimeter and test leads during operation.

3. Product Features

  • TrueRMS Measurement: Provides accurate readings for non-sinusoidal AC waveforms.
  • Large 6000 Counts Display: A 4-digit display offers clear, easy-to-read results.
  • Auto Ranging: Automatically selects the appropriate measurement range.
  • Auto Power Off: Conserves battery life by automatically shutting down after a period of inactivity.
  • Data Hold Function: Freezes the displayed reading for convenient recording.
  • Backlight: Improves visibility in dimly lit environments.
  • Polarity Identification: Automatically indicates positive or negative polarity for DC measurements.
  • Versatile Measurement Functions: Measures AC/DC Voltage, AC/DC Current, Resistance, Capacitance, Frequency, Duty Cycle, Diode, and Temperature.
Front view of the ANENG AN8002 Digital Multimeter display and dial

Figure 3.1: The clear 6000-count LCD display and function dial of the ANENG AN8002.

ANENG AN8002 Digital Multimeter with integrated kickstand extended

Figure 3.2: The multimeter shown with its integrated kickstand for convenient viewing.

4. Setup

4.1 Battery Installation

The ANENG AN8002 multimeter requires two (2) AAA batteries (not included) for operation.

  1. Ensure the multimeter is turned OFF.
  2. Locate the battery compartment cover on the back of the unit.
  3. Use a screwdriver to loosen the screw(s) securing the battery cover.
  4. Remove the battery cover.
  5. Insert two AAA batteries, observing the correct polarity (+ and -) as indicated inside the compartment.
  6. Replace the battery cover and secure it with the screw(s).
Back of ANENG AN8002 multimeter with battery compartment open

Figure 4.1: Open battery compartment on the back of the multimeter, showing where to insert AAA batteries.

4.2 Connecting Test Leads

Connect the test leads to the appropriate input jacks on the multimeter for the desired measurement.

  • Insert the black test lead into the COM (common) jack.
  • For voltage, resistance, frequency, capacitance, diode, temperature, and small current (mA) measurements, insert the red test lead into the VΩHz-I- jack.
  • For large current (up to 10A) measurements, insert the red test lead into the 10A jack.
ANENG AN8002 multimeter with red and black test leads connected to the input jacks

Figure 4.2: Test leads properly connected to the multimeter's input jacks.

Close-up of red and black test probe tips

Figure 4.3: Detailed view of the test probe tips for making electrical connections.

5. Operating Instructions

Before taking any measurements, ensure the test leads are correctly connected and the function dial is set to the appropriate measurement type.

5.1 Power On/Off

  • To turn on the multimeter, rotate the function dial from the "OFF" position to any desired measurement function.
  • To turn off the multimeter, rotate the function dial back to the "OFF" position.
  • The multimeter features an auto power-off function to save battery life. It will automatically shut down after a period of inactivity.

5.2 AC/DC Voltage Measurement

  1. Connect the red test lead to the VΩHz-I- jack and the black test lead to the COM jack.
  2. Rotate the function dial to the V~ (AC Voltage) or V- (DC Voltage) position. The meter will automatically select the range.
  3. Touch the test probes to the circuit points where voltage is to be measured.
  4. Read the voltage value on the display.

5.3 AC/DC Current Measurement

Caution: To measure current, the meter must be connected in series with the circuit. Incorrect connection can blow the fuse or damage the meter.

  1. For currents up to 10A: Connect the red test lead to the 10A jack and the black test lead to the COM jack.
  2. For smaller currents (mA): Connect the red test lead to the VΩHz-I- jack and the black test lead to the COM jack.
  3. Rotate the function dial to the A~ (AC Current) or A- (DC Current) position.
  4. Open the circuit where current is to be measured and connect the test probes in series.
  5. Read the current value on the display.

5.4 Resistance Measurement

  1. Connect the red test lead to the VΩHz-I- jack and the black test lead to the COM jack.
  2. Rotate the function dial to the Ω (Resistance) position.
  3. Ensure the circuit under test is de-energized and all capacitors are discharged.
  4. Touch the test probes across the component to be measured.
  5. Read the resistance value on the display.

5.5 Capacitance Measurement

  1. Connect the red test lead to the VΩHz-I- jack and the black test lead to the COM jack.
  2. Rotate the function dial to the µF (Capacitance) position.
  3. Ensure the capacitor under test is fully discharged before connecting the probes.
  4. Touch the test probes across the capacitor terminals.
  5. Read the capacitance value on the display.

5.6 Frequency and Duty Cycle Measurement

  1. Connect the red test lead to the VΩHz-I- jack and the black test lead to the COM jack.
  2. Rotate the function dial to the Hz/% (Frequency/Duty Cycle) position.
  3. Touch the test probes to the signal source.
  4. Press the "SEL" button to toggle between Frequency (Hz) and Duty Cycle (%).
  5. Read the value on the display.

5.7 Diode Test

  1. Connect the red test lead to the VΩHz-I- jack and the black test lead to the COM jack.
  2. Rotate the function dial to the Diode symbol position (often shared with continuity or resistance).
  3. Ensure the diode is disconnected from the circuit.
  4. Touch the red probe to the anode and the black probe to the cathode of the diode. A forward voltage drop (e.g., 0.5V to 0.8V for silicon diodes) will be displayed.
  5. Reverse the probes. The display should show "OL" (Open Loop) for a good diode.

5.8 Temperature Measurement

  1. Connect the red test lead to the VΩHz-I- jack and the black test lead to the COM jack.
  2. Rotate the function dial to the °C/°F (Temperature) position.
  3. If using a K-type thermocouple (not included, but often used with multimeters for temperature), connect it to the appropriate jacks (usually the VΩHz-I- and COM jacks, or dedicated temperature jacks if present).
  4. Place the thermocouple probe on or near the object whose temperature is to be measured.
  5. Read the temperature value on the display. Press "SEL" to switch between Celsius and Fahrenheit.
ANENG AN8002 multimeter with test leads

Figure 5.1: The multimeter ready for various electrical measurements with test leads.

6. Maintenance

6.1 Cleaning

Wipe the case with a damp cloth and mild detergent. Do not use abrasives or solvents.

6.2 Battery Replacement

When the low battery indicator appears on the display, replace the batteries as described in Section 4.1. Always use two new AAA batteries of the same type.

6.3 Fuse Replacement

If the current measurement function stops working, the fuse may need replacement. Refer to the specifications for the correct fuse type and rating. To replace the fuse, you will need to open the meter's casing, which should only be done by qualified personnel. Ensure the meter is disconnected from all power sources and test leads before attempting fuse replacement.

Back of ANENG AN8002 multimeter with battery cover closed

Figure 6.1: The back of the multimeter, showing the battery compartment cover.

7. Troubleshooting

  • No Display: Check battery installation and ensure batteries are not depleted. Replace if necessary.
  • "OL" (Overload) Indication: The measured value exceeds the selected range. For auto-ranging meters, this indicates the value is beyond the meter's maximum capability for that function.
  • Inaccurate Readings:
    • Ensure test leads are properly connected and not damaged.
    • Check battery level; low batteries can affect accuracy.
    • Verify the correct function and range are selected.
    • Ensure proper contact between probes and the circuit.
  • Current Measurement Not Working: Check the fuse. If blown, replace it with a fuse of the correct rating.

8. Specifications

ParameterValue
BrandANENG
ModelAN8002
Measuring ModeA/D
Sampling Rate3 times/second
Over Range IndicationOL
Frequency Measuring Range1Hz to 10MHz
Temperature Measuring Range-20℃ to 1000℃ (-4℉ to 1832℉)
Capacitance Measuring Range10pF to 6000uF
AC Voltage Measuring Range0.1mV to 750V
DC Voltage Measuring Range(Information cut off in source, typically similar to AC range)
Display6000 Counts, 4-digit LCD
Power Supply2 x AAA batteries (not included)
Item Weight9.8 ounces
Package Dimensions5.91 x 5.51 x 1.57 inches

Note: Specifications are subject to change without notice.

9. Warranty and Support

For warranty information or technical support, please refer to the product packaging or contact the manufacturer, Eujgoov, directly through their official channels.

© 2023 Eujgoov. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.